Measuring Instruments & Electrical Equipment
Aadiushmaa Absorption & Instrument Engineers is a well established name in the industry, engaged in trading and distribution of a variety of measuring instruments and electrical equipment like pressure instrument, electronic pressure instrument, gauges and other measuring instruments. Our products are sourced from respectable brands and supplied across the country at reasonable prices. The wide array of our products comprises of the following:
|
 |
|
|
|
|
|
 |
|
 |
 | |
 |
 | Indicating instruments for gauge, absolute and differential pressure with bourdon tube, diaphragm or capsule pressure element. These measuring instruments, which cover pressure ranges from 0...2.5 mbar to 0...7,000 bar and accuracies of up to 0.1%, can also be equipped with mechanical, electrical and electronic accessories and combined with a variety of diaphragm seal solutions. - Commercial Gauges :
Available in sizes 40, 50, 63, 100 mm with pressure range upto 600 Kg/cm2 - Hydraulic Gauges:
Available in sizes 63 & 100 mm with pressure range upto 1000 Kg/cm2 (Optional - Glycerine Filling) - Industrial Gauges:
Available in sizes 100 & 160 mm with pressure range upto 600 Kg/cm2 with SS 316 & SS 316L Bourdon tube options. - Test Gauges (Master Gauge):
Available in sizes 160 & 250 mm with pressure range upto 1000 Kg/cm2 and upto accuracy level of 0.1% with NABL certificate. - Capsule Gauges:
Available in sizes 63 & 100 mm and pressure range from 400 mmWC to 6000 mmWC with Commercial and Industrial range. - Electrical Alarms Contacts :
Can be incorporated with all relevant pressure and temperature measuring instruments. Inductive alarm contact, also available in safety pattern. Highly reliable and long service life. - Diaphragm Seal Gauges:
Can be incorporated with all relevant pressure gauges. Diaphragm seal available in SS 316L, Hastalloy, Monel, Tantalum, PTFE coating, capillary option etc. Filling liquid options are KN2.2 Silicon Oil, KN3.2, KN21 Helo carbon, KN 62 Paraffin (FDA Approved). - Temperature Gauges:
Available in sizes 100 & 160 mm with Temperature range upto 600 °C in SS 316 with bottom and back option. Also available in 360° rotatable stem.
 |  |
|
|
|
 |
|
 |
|
 |
 |
Electronic Pressure Instrument |
 |
 |
|
|
|
 |
|
 |
|
|
|
|
 |
 |
|
 |
|
|
 |
 |
Surge Protection Devices (SPD) |
 |
 |
|
|
|
 |
|
 |
|
|
 |
How do Surge Protection devices work: Surge protection devices (SPDs) can be thought of as safety pressure valves that prevent the build up of excessively dangerous voltage in power system. SPDs are installed across the power supply / signaling / data / communication lines before the equipment to be protected and are normally in a high impedance state having no effect on the circuit operation. A Surge Current Pulse (waveform) is defined by the time taken by the surge to reach its maximum value & then the time taken by the surge to reach its half of the maximum value.
For example this waveform addresses true lightning and time/ duration of stroke by producing 50,000 amps in 10 ìs. After 350 ìs, the waveform is still at 25,000 amps. In this example the waveform of the surge is designated as 10/350 ìs with the amplitude of 50 kAmp. Similarly the switching surges are addressed by a waveform of 8/20 microseconds, for example a surge current of 20,000 amps in 8 ìs, coming down to 10,000 amps at 20 ìs can be termed as the surge of 8/20 ìs, with 20 kAmp amplitude.
First stage: The arrester Class B type (as per VDE classification) - lightening current arresters are based on the spark gap technology that operates by arc chopping principle with a rating for arresting lightening currents of up to 100 kA for lightening current pulses of 10/350 ìs and is installed at the main distribution area of the power supply.
Second Stage: It is the medium level protection. The arrester class C type (as per VDE classification) are single, high capacity varistor based surge voltage arresters that are available with at least one time surge arresting capacity of 40 kA, 8/20 ìs pulse and a repeated capacity for 20 kA, 8/20 ìs pulses. The technology used is that of MOV with an indication to check its proper functioning and are installed at sub distribution level.
 |  |  |
|
|
 |
 |
|
 |
|
|
 |