Model AB-101T is designed to have all parameters of two winding of any transformer in a single go.This is particularly used to have full transformer data is available on PC.Micro-Controller based meter,that provides all parameters that are selected to be available on PC with two winding jig.It normally gives L,R & Q but other parameters can be selected.. With basic accuracy of 0.2 %.it offers various test frequencies . Four wire measurement minimizes error in reading. RS232 Communication and Binning facilty upto 8 bins possible. Loading of pre-setted parameters also possible to save time.
Model AB-101H is an economically priced LCR meter. It is Micro-processor based with basic accuracy of 0.25%.It offers various test frequencies ,can display Q ,has internal Bias for electrolytic capacitors. LCand R are two selectable functions with auto-ranging facility .Four wire measurement minimizes error in reading. Range locking facility provides fast measurements at production centers. SER and PAR modes are available.
Coil turns Tester model AB-301 is used to measure the number of turns of a coil immediately after it is wound. It consists of readout unit and selected platform. Same readout unit can be used with different type of platforms.
Quick and easy to operate it provides an instant readout of turns, and performance is not affected by a normal workshop environment.
In operation the setting/calibration is made against a standard coil.
The coil under test is placed on the appropriate platform and the ends of the coil are connected to the pair of terminals. The number of turns of a test coil is indicated on the digital readout immediately after making the connection.
The coil turns tester that has no moving parts may be used in conjunction with any of the plug-in platform described in the leaflet.
The platforms type 301-1 and 301-2 cover the most commonly found sizes of wound bobbins or self-supporting coils.
Simple to use, the bobbin is placed over the probe and the termination leads, connected to the platform.
The number of turns on the bobbin is then instantly on the readout unit.
Shorted Turns Tester model AB-401 indicates interturn short in the windings. If a coil containing a shorted turn is placed over other one of the probes, the bridge will become unbalanced and cause the meter needle to deflect into red zone of the scale.
Gauge selector is provided for large, medium, fine wires. As very less voltage is present it is very safe to operator.
Also as there is no connection is to be done ,operation is very fast & makes it suitable for checking large production batches.
The instrument has an extremely sensitive balanced AC inductance bridge. Coils within the instrument thus creating a field around the probes energize the probes over which the coil is to be tested is placed. Initial Balance is achieved by nulling the meter with the controls marked P1 and P2.These controls are the in-phase and quadrature balance controls for the bridge. After balancing it is ready to use.
Wide frequency range :DC to 2/3/5/10/20 MHz Versatile waveforms :Sine Triangle, Square, Ramp DC Offset to work with other TTL /ETL logics. Duty cycle control to have pulse/ramp FM modulation is available. Easy selection of frequency with push button & Fine control Frequency and Amplitude. display with 4 Bright red LEDs
Download Product Brochure Click Here
Function Generator model AB-202B/203B/205B/2010B/2020B is for general purpose use .Signals with Frequencies upto 2/3/5/10/20 MHz ,distortion free sine wave, symmetrical square wave, linear triangle wave makes it ideal in any lab. Metal case makes it rugged for educational use. It has good level flatness over entire frequency range with short circuit protection.
They are best suitable for broad band testing, in a field of sound engineering, testing of Pulse equipments, academic institutions,R and D Labs etc.
High Voltage Tester model AB-502 is used to test insulation .Clips at both probes makes it safe to use. Timer is provided which can be set from 0 minutes to 5 minutes. Tripping current or (leakage current allowance)setting can be from 0-30mA.
Provides supply in CV and CC mode Available voltages 30V/50V/70V/100V Available currents 2A/5A/10A Measures DC resistance of winding including contact resistance Higher current upto 3 A provided. Resolution of 0.1microohm. Automatic zeroing facility for thermal voltages. Dampening of Oscillations facility for fast stability of readings. 4 terminal Kelvin clips for accuracy.
Download Product Brochure Click Here
Regulated power supplies from AB instruments provide a very stable,regulated power for a long time. Short circuit protected makes it ideal for any use.Constant voltage and constant current are the two modes.
Dual and tracking power supplies are the versions available.
Measures DC resistance of winding including contact resistance Higher current upto 3 A provided. Resolution of 0.1microohm. Automatic zeroing facility for thermal voltages. Dampening of Oscillations facility for fast stability of readings. 4 terminal Kelvin clips for accuracy.
Model AB-601 is for measuring DC resistance to a great accuracy of 0.1%.A 4 & ½ Digit LED display is provided. A large current of 3 amps makes it suitable to majority of readings. Auto zeroing facility trims the thermal voltages generated while testing. Download Product Brochure Click Here
Special dampening circuit ensures fast stability of reading . Specially made Kelvin clips are integral part of unit for further accuracy. It is suitable for testing wound components, contact resistance, bus bar resistance, material purity etc.
Banga Industries Manufacturer and exporter of digital thermometer, hospital digital thermometer, medical digital thermometer and industrial digital thermometer. Also offer elastic bandages, crepe bandages, lumber sacro belt, abdominal belts and cervical collars.
Mediline Engineers Supplier and manufacturer of measuring instruments such as air flow meters, flow meters, gas flow meters, oxygen meters, ward vacuum units, regulator with flow meters, hospital oxygen flow meters.