Accuracy | + 2 dB |
Display | 3 1/2 digits |
Time Weighting | Slow & Fast |
Power | One 9 V battery |
Resolution | 0.1 dB |
Frequency Range | 31.5 Hz to 8 KHz |
Frequency Weighting | A & C |
Dynamic Range | 65 dB |
Operating Condition | 0dig C to 40dig C Less than 80% R. H. |
Standard Applied | IEC 651 Type 2 |
Range | LO (Low)-Weighting: 35-100 dB, HI (High)-Weighting: 65-130 dB |
Accessories | Instruction Manual, 9 V Battery, Carrying case, Screwdriver, Windscreen |
Weight | 215 g |
Size | 240 mm(L) x 68 mm(W) x 25 mm(H) |
The determination and control of Air bone noise has been a vital problem in recent years. It is now generally appreciated that high level noise is detrimental to the normal health and efficiency of the individual, and frequently indicates a fault in the manufacture or design of a product.
Sound waves cause variations in the normal atmospheric pressure. This variation in pressure is measured in dynes per square centimeter. For convenience, a logarithmic scale of decibels is used for sound level measurements. The sound pressure level is defined as the ratio in decibels of the magnitude of the sound pressure to the standard reference sound pressure of 0.0002 dyne per square centimeter.
The Sound Level Meter provides the essential basic instrument for such investigations, since it measures, on an internationally standardized decibel scale, the value of the alternating pressure waves of the air which are caused by the sound.
ACD is making available instrument S-3000 which confirms to the requirements of ‘Type 2’ instrument as per IS 9779-1981.
This instrument consists of electret microphone, impedance matching circuits, high gain amplifier, attenuator, precise weighting networks and digital meter.
The instrument with accessories is housed in a sturdy portable case.
Features:
- Electret Condenser Microphone
- Direct Digital Reading
- 35 db to 130 db Range
- A & C Weightage
- Fast & Slow Response
Auxiliary Output:
- AC conditioned, 0.65Vrms corresponding to each range step, impedance: 600 W DC conditioned, 10mV/dB (nominally)
Additional Information:
- Item Code: S-3000
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Brand | ACD |
Weight | Sensor - 130 gms, Instrument - 655 gms, Total with Carry Case - 1080 gms |
Response | Fast & Slow |
Packing Type | Box |
Sound Range | 40 dB - 140 db |
Digital Sound Level Meters are two most important parameters for monitoring the machine health. Regular logging of these two parameters provides early warning of breakdown we are offering portable instruments for individual parameters as well as an integrated meter.
Sound:
- Analogue Meter
- 40 db to 140 db Range
- A & C Weightage
Other Details:
- Condenser Microphone
- Analogue Meter
- A & C Weightage
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Weight | 215 g |
Range | LO (Low)-Weighting: 35-100 dB, HI (High)-Weighting: 65-130 dB |
Accuracy | + 2 dB |
Frequency Weighting | A & C |
Operating Condition | 0dig C to 40dig C Less than 80% R. H. |
Display | 3 1/2 digits |
Power | One 9 V battery |
Size | 240 mm(L) x 68 mm(W) x 25 mm(H) |
Resolution | 0.1 dB |
Frequency Range | 31.5 Hz to 8 KHz |
Standard Applied | IEC 651 Type 2 |
Accessories | Instruction Manual, 9 V Battery, Carrying case, Screwdriver, Windscreen |
Dynamic Range | 65 dB |
Time Weighting | Slow & Fast |
The determination and control of Air bone noise has been a vital problem in recent years. It is now generally appreciated that high level noise is detrimental to the normal health and efficiency of the individual, and frequently indicates a fault in the manufacture or design of a product.
Sound waves cause variations in the normal atmospheric pressure. This variation in pressure is measured in dynes per square centimeter. For convenience, a logarithmic scale of decibels is used for sound level measurements. The sound pressure level is defined as the ratio in decibels of the magnitude of the sound pressure to the standard reference sound pressure of 0.0002 dyne per square centimeter.
The Sound Level Meter provides the essential basic instrument for such investigations, since it measures, on an internationally standardized decibel scale, the value of the alternating pressure waves of the air which are caused by the sound.
ACD is making available instrument S-3000 which confirms to the requirements of ‘Type 2’ instrument as per IS 9779-1981.
This instrument consists of electret microphone, impedance matching circuits, high gain amplifier, attenuator, precise weighting networks and digital meter.
The instrument with accessories is housed in a sturdy portable case.
Features:
- Electret Condenser Microphone
- Direct Digital Reading
- 35 db to 130 db Range
- A & C Weightage
- Fast & Slow Response
Auxiliary Output:
- AC conditioned, 0.65Vrms corresponding to each range step, impedance: 600 W DC conditioned, 10mV/dB (nominally)