We offer Microcontroller based Motor Protection Devices (µ-MPD), Microcontroller based Voltage Protection Device (µ-VPD), Control Panel (µ-Auto Starter), Ammeter (µ-AMPS), Temperature Controllers/Data Loggers (µ-CON) and Humidity Controllers(µ-Th).
µ-MPD will enhance the reliability of motors. It avoids shutdowns due to burning of motor. Thus, loss of time and rewinding expenditure can be avoided by using µ-MPD device.µ-MPD are most ideally suited for round the clock protection of Motors, Pumps, Blowers, etc.
 |
|
 |
|
 |
|

|
|
Motor Relays
µ-MPD-Split Type
- Man-machine interface through keyboard & display.
- Extra-wide range (with single turn) to reduce the inventory and maintenance.
- In-built single phase (in partial well), phase reversal, unbalance &overload, earth fault, lock rotor, dry run, short circuit.
- Pre-alarm, password, inbuilt star-delta timer.
- Digital ammeter with auto scanner (settable scroll time).
- Twenty point annunciation, more than mere annunciation, it displays the faulty phase and value at which tripping has occurred.
- Available as basic unit from 0.8-5A (uptp3 HP), 2-22A (upto15HP), 4-44(upto 30HP with inbuilt CTs) & 40-220A (upto160HP), 80-440A (upto 375HP), 200-1200A (upto 800HP) with single turn can be used for any current range by using external CTs.
- Provides accurate overload protection by virtue of release time accuracy.
- Software calibration facility. Simple to install with straight-through wiring.
|
|
 |
|
|
|
 |
 |
|
|
|
 |
 |
|
 |
|
 |
|

|
|
Motor Protection Relays
µ-MPD
- Man-Machine interface through keyboard & display.
- Extra-wide range (with single turn) to reduce the inventory and maintenance.
- In-built single phase (in partial well), phase reversal, unbalance & overload, earth fault, lock rotor, dry run, short circuit.
- Pre-alarm, password, inbuilt star-delta timer digital ammeter with auto scanner (settable scroll time).
- Twenty point annunciation, more than mere annunciation, it displays the faulty phase and value at which tripping has occurred.
- Available as basic unit from 0.8-5A (uptp3 HP), 2-22A (upto15HP), 4-44(upto 30HP with inbuilt CTs) & 40-220A (upto160HP), 80-440A (upto 375HP), 200-1200A (upto 800HP) with single turn can be used for any current range by using external CTs.
- Provides accurate overload protection by virtue of release time accuracy.
- Software calibration facility. Simple to install with straight-through wiring.
- Advance RS 485 serial communication port.
|
|
 |
|
|
|
 |
 |
|
|
|
 |
|