XFP501/X: XFP Networkable one loop 32 zone panel Agni Context Plus XP95 protocol. Code entry, c/w 3A psu, metal enclosure.
XFP501K/X: XFP Networkable one loop 32 zone panel Agni Context Plus XP95 protocol. Keyswitch entry, c/w 3A psu, metal enclosure.
Standard Features
Full compatibility with the Context Plus XP95 range of smoke and heat deteactors, call points, sounders and control modules.
The ability to interconnect up to eight XFP main panels (any variant) plus an additional four XFP Repeater panels per main onto a two wire RS485 network.
Two independently programmable conventional sounder circuits.
The Oriel series of Microprocessor based fire alarm panels are an upgraded version which provides a reliable and cost effective solutions to fire detection, from small to large size installations which have 2, 4, 6, 8 & could go up to 60 zones of selecting models and features. These units have been designed to offer high standards of performance, reliability and quality and comply with IS 2189 : 1999 and tested by the ERTL (N).The Oriel series panels are specially suited for the small offices, workplaces, small & high rise buildings.
Standard Features
Designed to comply with EN54 parts 2 and 4 and Australian Standard AS4428.1.
Full compatibility with the Context Plus XP95 range of smoke and heat detectors, call points, sounders and control modules.
4 to 32 loop capability.
Up to 64 Network nodes.
Network panel access selectable by detector group, loop, panel or global.
Ultrafast RS422, Full Duplex, Fault tolerant, Peer to Peer communication.
The Context Plus XP95 ionisation smoke detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Stainless steel wiper contacts connect the detector to the terminals in the mounting base. Inside the detector case is a printed circuit board that has the ionisation chamber mounted on one side and the address capture, signal processing and communications electronics on the other.
The ionisation chamber system is an inner reference chamber contained inside an outer smoke chamber. The outer smoke chamber has smoke inlet apertures that are fitted with an insect resistant mesh.
The radioactive source holder and the outer smoke chamber are the positive and negative electrodes respectively. An americium 241 radioactive source mounted within the inner reference chamber irradiates the air in both chambers to produce positive and negative ions. On applying a voltage across these electrodes an electric field is formed. The ions are attracted to the electrode of the opposite sign, some ions collide and recombine, but the net result is that a small electric current flows between the electrodes.
Context Plus XP95 temperature (heat) detectors have a common profile with ionisation and optical smoke detectors but have a low air flow resistance case made of self-extinguishing white polycarbonate. They monitor temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature.
The response to temperature increases of the standard temperature detector (part no: 55000-400IMC) enables the detector to be utilized as an EN54 Grade 2 heat detector.
To provide a device for use in ambient temperatures of up to 50°C, a high temperature detector (part no: 55000-401IMC) is also available. This has similar characteristics to the standard temperature detector at 25°C but reaches a 55 count (alarm) at 90°C.
The Context Plus XP95 multisensor detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value.
The multisensor construction is similar to that of the optical detector but uses a different lid and optical mouldings to accommodate the thermistor temperature sensor. The sectional view (below) shows the arrangement of the optical chamber and thermistor.
The signals from the optical smoke sensing element and the temperature sensor are independent, and represent the smoke level and the air temperature respectively in the vicinity of the detector. The detector’s microcontroller processes the two signals. The temperature signal processing extracts only rate of rise information for combination with the optical signal. The detector will not respond to a slow temperature increase – even if the temperature reaches a high level. A large sudden change in temperature can, however, cause an alarm without the presence of smoke, if sustained for 20 seconds
The Context Plus XP95 manual call point is tough, durable and highly visible.
A single alarm LED is provided on the call point. This LED is controlled, independently of the call point, by the control and indicating equipment (CIE).
The call point’s address is set at the commissioning stage by means of a seven-segment DIL switch.
Call points can be remotely tested from the CIE by transmission of a single bit in the communications protocol. Call points respond by providing a value of 64 which corresponds to the alarm value. The CIE should recognize this response as a test signal and should not raise a general alarm.
All Context Plus XP95 smoke and heat detectors fit the Context Plus XP95 mounting bases. The base is a zero insertion force base with dual finger receptacles of stainless steel into which the detector terminals slide. Cable connections of up to 2.5mm diameter are made via captive cable clamps.
There are four double terminals and one single terminal.
L1 line IN and OUT, double terminal L2 line IN and OUT, double terminal + Rremote LED positive supply, double terminal - Rremote LED negative supply, double terminal
The Context Plus XP95 20D isolating base senses and isolates short circuit faults on loops and spurs. The base is loop powered, polarity sensitive and accepts the XPERT card to set the associated device address.
In short circuit conditions, the integral yellow LED is illuminated. The detector associated with the base remains active under short circuit conditions. Power and signals to the affected section are restored automatically when the fault is cleared.
Under normal operating conditions, a low impedance is present between the – IN and – OUT terminals of the base, so that power and signals pass to the next base in the line.
If a short circuit or abnormally low impedance occurs, the fall in voltage is sensed and the base isolates the negative supply in the direction of the fault.
Three evacuate tones (continuous, warble or sweep) and one Alert tone
High (100dB @ 1m) and low (94dB @ 1m) volume settings
A BS5839 part 1 2002 Clause 12.2.2 compliant locking facility
A ‘quick-fit’ bayonet fixing arrangement
‘Master’ or ‘shadow’ mode operation (allows multiple shadow sounders to be given the same ID address as one ‘master’ sounder, a useful feature on heavily populated systems and to give synchronized sounding)
A group addressing facility allowing multiple sounders to be activated simultaneously
IP43 rated shallow and IP65 rated deep base versions are available.
The addressable VXB beacon utilizes the latest developments in surface mount LED technology to provide a cost-effective addressable beacon that is big on visibility but low on current consumption. Flashing once a second in evacuate or alert mode, its features include:-
Standard Features
Straightforward DIL switch addressing.
Attractive low profile design.
A ‘quick-fit’ bayonet fixing arrangement.
A typical alarm current of just 3mA @ 24V.
Master of ‘shadow’ mode operation.
A group addressing facility.
A BS5839 Part 1 2002 Clause 12.2.2 compliant locking facility.
The Orion series of Microprocessor based fire alarm panels provides a reliable and cost effective solutions to fire detection, from small to large size installations which have 2, 4, 6, 8 & could go up to 60 zones of selecting models and features. These units have been designed to offer high standards of performance, reliability and quality and comply with IS 2189 : 1999 and tested by the ERTL (N).The Orion series panels are specially suited for the small offices, workplaces, small & high rise buildings.
The Oriel series of Microprocessor based fire alarm panels are an upgraded version which provides a reliable and cost effective solutions to fire detection, from small to large size installations which have 2, 4, 6, 8 & could go up to 60 zones of selecting models and features. These units have been designed to offer high standards of performance, reliability and quality and comply with IS 2189 : 1999 and tested by the ERTL (N).The Oriel series panels are specially suited for the small offices, workplaces, small & high rise buildings.
Standard Features
Complies to IS 2189: 1999 and Tested by ERTL (N).
2 X 16 character backlit LCD display. (4 x 20 character, optional).
64 / 128 / 256 / 512 Events logging facility with real time clock and keypad.
The Electronic sounder is designed for use within fire alarm systems, security systems and industrial signaling systems. Combined sounder and beacon provides an audio-visual warning which is suitable for place which requires high sound output and visual indication.
The Electronic sounder is designed for use within fire alarm systems, security systems and industrial signaling systems. Combined sounder and beacon provides an audio-visual warning which is suitable for place which requires high sound output and visual indication.
The unit is designed to ensure that Alarm Signal can be actually transmitted to all locations. To prevent any missing signal specially for the close room.
The unit is designed to ensure that Alarm Signal can be actually transmitted to all locations. To prevent any missing signal specially for the close room.
The unit is designed to ensure that Alarm Signal can be actually transmitted to all locations. To prevent any missing signal specially for the close room.
The detectors can automatically match codes with alarm host. It’s simple and fast.
1-100 independent wireless zones can be armed or disarmed independently. Common zone and emergency zone can be defined at will.
Two groups of timer-open /timer-close time can be set ,and it also indicate the current state.
Three kinds of alarm sound and four levels of alarm volumes are optional.
10 pieces of latest alarm massages can be scroll display simultaneously.
60 pieces of latest alarm messages can be inquired.
A group of normal open, a group of normal close and + 12V DC outputting are provided to control other devices (e.g., startup alarm siren, alarm light, alarm linkage and etc.)
Rechargeable backup Battery (12V1.2Ah) is optional.
It has 1-299 or 999 independent wireless zones. Each can be armed or disarmed independently. It also can be defined to common zone and emergency zone independently.
The code of detector or wireless emitter can be learned to alarm host automatically or trigger by hand.
Super- large LED display and voice guide make alarm more humanly and easily.
Two access codes (installer code and user code) manage separately, and the code is modifiable to prevent program from distorting at ill will.
The alarm host has two timers. It can recognize on/off state automatically, and also indicates present ( on/off) state.
Five pieces of up-to date alarm message can be scroll to display simultaneously.
Inquiring 100 pieces of up-to-date records (including alarm message and indicate message)
A normal open/close output and +12V DC output are provided to control other devices (e.g. startup alarm siren, alarm light, alarm linkage etc.)
It has 1-299 or 999 independent wireless zones. Each can be armed or disarmed independently. It also can be defined to common zone and emergency zone independently.
The code of detector or wireless emitter can be learned to alarm host automatically or trigger by hand.
Super- large LED display and voice guide make alarm more humanly and easily.
Two access codes (installer code and user code) manage separately, and the code is modifiable to prevent program from distorting at ill will.
The alarm host has two timers. It can recognize on/off state automatically, and also indicates present ( on/off) state.
Five pieces of up-to date alarm message can be scroll to display simultaneously.
Inquiring 100 pieces of up-to-date records (including alarm message and indicate message)
A normal open/close output and +12V DC output are provided to control other devices (e.g. startup alarm siren, alarm light, alarm linkage etc.)
16-zone (8 wireless and 8 wired) with 4*4 keyboard and lattice LCD display
Voice pre-recorded
8 partitions can be programmed independently. 8 remote controllers and 8 users code can be programmed for 8 partition to ARM/DISARM independently.
Support to ADEMCO CONTACT ID and KS6+2 monitoring center communication protocol
Access codes, 1 installer code, 1 master code, 8 common user code and duress code
Dial 5 telephone numbers (mobile and pager number). Dialing type (tone or pulse) and appointed communication zone can be programmed. Alarm telephone is priority.
Option for ARM/DISARM and system status report or not.;
Phone line cut or short-circuit will send an alarm. (indicator or siren for optional)
Remote Arm, Disarm, monitor and on-site alarm setup.
Star Metal Forms Private Limited Engaged in manufacturing and supplying of fire retardant doors, commercial fire retardant doors, industrial fire retardant doors, epoxy painted doors and silicon epoxy painted doors which are fire proof.
Aakash Fire Safety Engaged in manufacturing of fire fighting equipment, fire extinguisher, portable foam equipment, protection equipment, safety belt, fire hose, fire refill, body protection equipment, face protection equipment and eye protection equipment.
Shakti Fire Services Manufacturer and supplier of fire fighting and fire-protection equipments such as non-percolating fire hoses, monitors nozzles, ionization smoke detectors, optical smoke detectors, stand pipes and fireman axes etc.