Our clients can avail from us Fire Protection Systems. Some of these items include Gloves, Fire Extinguishers, Fireproof Jackets and Suits. These items are designed in compliance with fire safety standards. We also offer these items as per our client's requirements.


  Fire Hydrant Systems

A Fire Hydrant is an above-ground connection that provides access to a water supply for the purpose of fighting fires. Fire hydrant systems are an installation of pipes, water tanks, pumps, hydrant outlets and / or hose reels.

Hydrant Systems can be of two types:

(a) External Hydrant System, where the hydrants are installed in the open, like the city or town water mains, or hydrant systems installed in the open areas in industrial or such other occupancies and

(b) Internal Hydrant System, installed in buildings or structures to be protected


We design an integrated Hydrant System as per national and international norms. We consider capacity of fire pump, size and arrangement of pipes used for hydrant system, pressure at hydrant point against the available fire risk. Our designed Hydrant System is an arrangement of piping, valves, hose connection and allied equipment installed in building and structure with connection located in such a manner that water can be discharge in stream of spray patterns through attached hose and nozzle for the purpose not only extinguish the fire but at the same time save the occupants and contents of area in with better response time.


We design hydrant system as per TAC, NBC, Indian, OISD and NFPA Standards/ guideline.


Almost all part of the premises shall be covered by such system. Our designed system is not only complying the national and international norms/ guideline but also considered the exact requirement to minimize the cost at same time, increase the effectiveness of system for maximum gains.



Fire Hydrant Systems

Enlarge View



  Fire Sprinkler Systems

In smaller workplaces, portable fire extinguishers will probably be sufficient to tackle small fires. However, in more complex buildings, or where it is necessary to protect the means of escape and/or the property or contents of the building, it may be necessary to consider a Sprinkler System. Sprinkler systems are traditionally acknowledged as an efficient means of protecting buildings against extensive damage from fire. They are also now acknowledged as an effective means of reducing the risk to life from fire. Systems are being developed which may be suitable for use in workplaces with residential areas, such as care homes and houses in multiple occupancy. Sprinkler systems need to be specifically designed and installed to the appropriate hazard category in accordance with an approved code of practice.


We offer Design & Engineering of an integrated Sprinkler System with fine protection engineering standards Network of specially sized or hydraulically designed piping installed in building, structure generally overhead with attached sprinkler in a systematic pattern proper location of alarm valve and orientation as per our best design practice makes us leader in designing this system.


We design sprinkler system as per TAC, NBC,Indian and NFPA Standards/ guideline.



Fire Sprinkler Systems

Enlarge View



  Water Spray System

Water Spray System is a special fixed pipe system connected to a reliable source of pressurised water supply and equipped with water spray nozzles for application on area / equipment to be protected. The system can be operated automatically by connection to an automatic detection and alarm system or manually, or both.


These systems can be used for any one or more of the under mentioned purposes:


  • Extinguishment of fire

  • Control of fire

  • Exposure protection (cooling)

  • Prevention of fire (cooling)


The suppression or extinguishment of fire is achieved by cooling, dilution of oxygen supplies (smothering), dilution (or removal) of the liquid fuel (starvation or emulsification).


Water spray systems are generally used for fire protection of flammable liquid and gas storage tanks, piping, pumping equipment, electrical equipment such as transformers, oil switches, rotating electrical machinery etc. and for protection of openings in fire walls and floors.


The type of water spray required will depend on the nature of the hazard and protection required.


Types of water spray systems:


There are two basic types of water spray systems installed as fixed systems. One of these is used to extinguish oil fires and usually referred to as .Water Spray Projector System. The other is mainly used to provide protection to plant, processes, equipment, and to prevent explosions, and is generally known as a .Water Spray Protector System


For more detail click the attached PDF :



Water Spray System

Enlarge View




  Water Mist Systems

Cylinder system operates similar to a gas extinguishing system. The cylinder system consists of two different types of cylinders, one type is filled with water at atmospheric pressure and the others with nitrogen pressurised to 200 bar, used as propellant.

The activation of a cylinder system is triggered by one master cylinder. This master cylinder will then activate all further slave cylinders.

In dry pipe deluge systems the activation is triggered by an electric signal from a separate detection system. The cylinder valve is a solenoid operated valve with manual override for safety reasons in case of electric failure. This opens the differential pressure valve to discharge the nitrogen into the slave cylinders.

In a wet pipe system a glass bulb triggers activation. The pressurised pipe system is connected to the cylinder valve on the master cylinder, which is a differential pressure valve. Activation is achieved by breaking a glass bulb located within the body of the nozzle. This causes the release of control pressure in the pressurised pipeline. This opens the differential pressure valve. The master cylinder will then activate different configurations of slave cylinder assemblies.

For More detail click the download button :

 



Water Mist Systems

Enlarge View




  Foam Systems

Foam fire extinguisher with floating foam cartridge afff solutions ensure particularly effective and practically residue-free extinguishing thanks to its strong wetting effect. The patented co2 overcharge guarantees even and powerful solution discharge at the same distance throughout the whole extinguishing process. our afff foam is a highly fluid, rapid foam which is capable of reaching everywhere. These characteristics make it the perfect option for areas with difficult access and storage density. the foam cartridge extinguisher with patented CO2 overcharge is available with 6 and 9 liters of extinguishing solution.


Areas of Application: 



I.E. Storage areas, Archives, Supply Rooms, Shipping, Mineral Chemistry, Agriculture (stables, barns, silos), Animal feed industry. 


Foam Systems








Contact Us
Ajinkya Fire Protection Services
Mr. Jitendra Kotwal (Manager)
Shop No. 3, Raunak Park, Tidke Colony, Near Mico Circle, Trimbak Road
Nashik - 422002, Maharashtra, India

Contact via E-mail


Member IndiaMART.com © Ajinkya Fire Protection Services. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited