Mobile Cath Lab
Mobile Cath Lab

Models
  • "Allengers Life" (Mobile cath lab 20 kw)

  • "Allengers Life +" (Mobile cath lab 40 kw)


A Digital Mobile Cardiovascular Angio System for applications in Cardiac Angiographies, PTCA, DSA, Valvuloplasties, Stenting & EP procedures.


X-Ray generator:

  • High frequency generator.

  • Designed for continuous, pulse & digital cine application

  • Complete inbuilt cooling system

  • Special heat management module is integrated in the system for efficient cooling for prolonged usage.


Imaging Chain (1k x 1k):

  • 1k x 1k 14 bit CCD camera.
  • Image processor with a complete cardiac & vascular package with all the latest features.

  • Real time DSA capabilities with edge enhancement, zoom, contrast & brightness .

  • The system is DICOM compatible.

Two no.s 20" medical grade, flicker free monitors for superb diagnostic image quality.


Table

  • Floating carbon fibre table top longitudnal transfer movement electomagnetic locks to lock the movement of top.

  • Motorised updown movement


Optional Motorised isocentric "C": A fully motorised "C" movement ensure operator comfort.

  • 1 rpm for orbital movement

  • 2 rpm for rotational movement.



Fixed Cath Lab
Fixed Cath Lab

Allengers- Pride   uses state of the art digital technology for unparalleled reliability for super performance user friendly & meeting the expectation of the cardiologist to give a packaged solution for cardiac & interventional imaging.
  • X-Ray generator high frequency (100 khz) & 100 kw high powered generator.
  • The system offer excellent image quality with 1k x 1k x 14 bit imaging chain.
  • All the moments are motorised that makes the system more user friendly.
  • Full heat management through external oil circulation with heat exchanger for cooling of excel tubes during continuous uses to ensure uninterrupted imagingAutomatic collimation through using parallel shutters/iris collimetor to minimise X-Ray dose to patient & surgeon.
  • Programmable C-Arm positions
  • A specialised digital image processor with all the latest features.
  • Angio-view work station is DICOM 3.0 compatible.
  • Urgent recovery system is a unique feature.
  • Data backup is made automatic to avoid data loss in case of any software hardware failure.
  • Floating table top with carbon fibre top.
  • Minimum attenuation with rectomagnetic locks & motorised up/down movement.
  • High contrast medical grade flicker free monitors for superb imaging with ceiling suspension.
  • AFD screen to display position of C-Arm (LAO, RAO, CAU, CRA).



Mammography Machine
Mammography Machine

MAM -4035 (VENUS SERIES):
Description:
  • Mammography Machine for Breast X-Rays.

  • Compatibility of Digital Stereotactic Biopsy Device.

  • 3.5 KW High frequency X-Ray Generator.

  • Automatic Exposure Control (AEC) Rhodium Filter.

  • Rotating Anode Dual Focus X-Ray Tube of Focal 0.1/0.3 mm2.

  • Motorized Breast Compression with Digital Display of comp. force.

  • KV : 22 to 35 KV.

  • MAS : 1 to 700 MAS.

  • 18 x 24 cm. Bucky with Grid.

  • Lead Glass.


Power Supply: 230V, AC, 50 Hz., Single Phase, 15 Amps., Power Socket.

Optional:
  • 24 x 30 cmm. Bucky with Grid.
  • Digital Stereotactic Biopsy Device: Its PC based operation makes it user friendly, safe & sophisticated.
    • System operational type: Xray film, CR casstte.
    • Biopsy Range: x = 60mm, y = 50mm.
    • Positional Control: Motorised (PC operated)
    • Soft compression device
    • LCD compression display
    • Provision for secondary targets prescription



Lithotripter
Lithotripter

Model: UROLITH+

Description:
  • Extra Corporeal Shock Wave Lithotripter (ESWL).

  • For treatment of Kidney, Ureter & Bladder Stones.

  • Non invasive treatment.

  • Under Water Spark Gap discharge technology (Shock Waves).

  • Feather Touch Control Panel.

  • KV Range : 14 to 25 KV.

  • Shocks Counter.

  • Used in conjunction with Allengers C-Arm Image Intensifier HF-46 URO, µP6/µP9 or HF-46/HF-49.

  • 3 Axis Table with Radiolucant Top.
  • Motorized movements in all directons with remote control.

Power Supply: 230V, AC, 50 Hz., Single Phase, 15 Amps., Power Socket.



High Frequency C-Arm
High Frequency C-Arm

Models:


  • Allengers-HF-46/32 Frames Memory/ 15" Monitors

  • Allengers-HF-49/32 Frames Memory/ 17" Monitors

  • Allengers-HF-46 (URO)

  • Allengers-HF-49 R PLUS

  • Allengers-HF-49 R 100


Description

  • High frequency, Mobile C-Arm Image Intensifier X-Ray T.V. system.

  • 3.5 KW/5 KW, 40 Khz. High frequency X-Ray Generator.
  • Suitable for general Ortho/URO procedures.

  • Monoblock Tube Head with Stationary Anode/ Rotating Anode X-Ray Tube of Dual focus.

  • Aluminium 'C'.
    9"/6" Image Intensifier.

  • 1/2" B/W, CCD Camera & Optics.

  • 32 Frame Image Memory or Digital image acquisition system.

  • 2 Nos. 15"/17" Monitors on a Trolley.


Power Supply 230/110V, 50/60Hz



X-Rays Machines (Line Frequency)
X-Rays Machines (Line Frequency)

Models:

    • Allengers-325/FC

    • Allengers-325/FC/Allpose/IITV

    • Allengers-525/FC

    • Allengers-525/FC/Allpose/IITV


    Description:

    • X-Ray machine for fixed application.

    • For Rad or Rax + FLR.

    • Full wave rectified X-Ray Generator.

    • Floor to Ceiling tube Stand, Fully counterbalanced.

    • Double Tank Cable Unit.

    • Rotating Anode X-Ray Tube, Dual focal spots of size 1.0/2.0mm2.

    • KVP Range:40 to 125 KVP.

    • Max. mA Output: 300 mA (Allengers 325 FC), 500 mA (Allengers 525 FC).

    • Timer Range:0.02 to 5 sec.


    Power Supply: 230/440 V AC, 50/60Hz.

    Compatible Tables: Allpose (Motorised, Multiposition, (Five Position Manual Tilt), Floatex Table (Four Way Floating), Horizontal Table)
    Optional: 2nd X-Ray tube, Image Memory Unit, Vertical Bucky Stand.



Whizrad
Whizrad

Whizrad unit are available with 300 mA & 500 mA line frequency generators & a complete range of high frequency generator (15 kw, 30 kw, 40 kw & 50 kw)
Description:
  • The Whizrad unit has been designed by Allengers keeping in-view all requirements associated with basic Radiographic Procedures.
  • The system complies with the guidelines as prescribed by World Health Organization (WHO).

  • This equipment can be supplied with Line frequency X-Ray Generators.

  • The Whizrad unit is a perfect system for Primary Health Centers, Distt. Hospitals & Emergency Units of Medical Colleges & Large Hospitals.



High Frequency Mobile X-Ray Machines
High Frequency Mobile X-Ray Machines

  • X-Ray Generators: 2.5 kw, 3.5 kw, 6 kw High Frequency (40 kHz)

  • Totally feather touch micro controller based control panel

  • Self diagnostic program with indicators to indicate earth fault, KV fault, Filament circuit fault & Thermal overload

  • Easy manouverability makes it most suitable for trauma cases & bed side X-rays in hospital wards

  • Substantially lower exposure factors hence less radiation hazards, safe for the operation & operators

X-Ray Tube Head
  • Mono block version

  • Stationary anode X-ray tube of focus 2.8 mm with MARS 2.5, MARS 3.5 & MARS 6
  • Rotating Anode X-Ray tube with MARS 6R, dual focus spot of size 0.3 & 0.6 mm

Stand
  • Spring Balance Mobile stand

  • Tube head can be moved up & down.
  • The tube arm can be rotated +/- 90 degree for side wise X-Rays.

Power supply: 230 volts AC Single Phase 15 A power socket.



High Frequency Mobile X-Ray Machines
High Frequency Mobile X-Ray Machines

  • X-Ray Generators: 15 kw & 30 kw High Frequency (40 kHz)

  • Totally feather touch micro controller based control panel

  • Self diagnostic program with indicators to indicate earth fault, KV fault, Filament circuit fault & Thermal overload

X-Ray Tube Head
  • Mono block version

  • Rotating anode X-ray tube of focus 0.6 mm & 1.3 mm.

Stand
  • Spring Balance Mobile stand

  • Tube head can be moved up & down.
  • The tube arm can be rotated +/- 90 degree for side wise X-Rays.

Power supply: 230 volts AC Single Phase 15 A power socket.



High Frequency Fixed X-Ray Machines
High Frequency Fixed X-Ray Machines

  • X-Ray Generator 15 kw, 30 kw, 40 kw, 50 kw.

  • High Frequency 40 khz

  • Application: Radiography, Radiography+Fluoroscopy

  • X-Ray Tube: Rotating anode dual focus

  • Tube Stands

  • Option of the following stands available:

    • Floor to ceiling

    • Floor to ceiling with fluoroscopy

    • Floor to ceiling with semi automatic spot film device
    • Whizrad universal stand
    • Ceiling free stand
    • Ceiling Suspension
    • Tables
    • Following table are available:
    • Horizon (Horizontal tables) with oscilating grid.

    • Multipose tables(Manually tilt 5 position table with oscilating grid
    • Floatex (Horizontal table with floating table top with oscilating grid
    • Floating table top, up/down movement with oscilating grid
    • Allpose table (Motor driven table with oscilating grid) with image intensifier (6", 9", 12")
    • RF table with fully-automatic SFD(Spot film device) & image intensifier (9" & 6") (New)

Power Supply: 220/440 volt 50/60Hz.



Portable X-Ray Machines
Portable X-Ray Machines

Allengers-30


Descrition

  • Portable X-Ray Machine

  • Foldable Stand

  • Light Weight

  • Ideal for Field & Trauma cases

  • Max. mA=30 mA.

  • Max. KV=85 KV.

  • Self rectified X-Ray generator with a Stationary Anode X-Ray Tube.

  • Single focal spot 1.8mm2

Power Supply: 230 V, AC, 15 Amps.



100 mA Mobile X-Ray Machine
100 mA Mobile X-Ray Machine

Allengers-100/CBM


Description

  • Mobile X-Ray Machine.

  • Counter balanced Mobile Stand.

  • Ideal for indoor use in Hospital Wards for bed-side X-Rays.

  • Easy to move & handle.

  • Articulated Tube Arm.

  • mA Range :25 to 100.

  • KVP Range:45 to 100.

  • Full wave rectified X-Ray Generator with self contained Tube Head.

  • Stationary Anode X-Ray tube with single focal spot of 2.8mm2.


Power Supply: 110/230 V AC, 50/60 Hz, 15 Amps.
Optional

  • Horizontal Table,

  • Rotating Anode Tube with Spring Balance Mobile Stand,

  • 100 mA Machine is also available with Floor to Ceiling stand.





Copyright © Allengers Medical Systems Limited, All Rights Reserved (Terms of Use)