Instrumentation For Indian Navy |
|
“Anadig Systems” manufacture and export Indigeneous anadig make Engine Room Instrumentation for EKM submarines & War Ships.
|
 | Engine Room Instrumentation | | |
| Indigenous and dig make engine room instrumentation for ekm submarine cakt - 02 for shafting and bearing temperature monitoring system cakt - 05 for diesel auxiliary temperature monitoring system cakt - 06 for battery temperature monitoring system
| cakt -02 | cakt-05 | cakt-06 | | channels | 24 nos | 06 nos | 12 nos | | range | 0-100ºc | 0-100° c | 0-100° c | | accuracy | 0. 5% of fsd ±1 digit | 0. 5% of fsd ±1 digit | 0. 5% of fsd ±1 digit | | sensor | 3 wire pt - 46 | 3 wire pt - 46 | 3 wire pt - 46 | | scan time | adjustable 1-20 sec | adjustable 1 - 20 sec | adjustable 1 - 20 sec | | display | 4 digit for parameter 2 digit for channel 2 digit for function | 4 digit for parameter 2 digit for channel 2 digit for function | 4 digit for parameter 2 digit for channel 2 digit for function | | alarm | individual alarm | individual alarm | individual alarm | | alarm contacts | nc - c - no contact common for all channel | nc - c - no contact common for all channel | nc - c - no contact common for all channel | | alarm indication | one led for each channel | one led for each channel | one led for each channel | | power supply | 220v ac, 400 hz | 127v ac, 50 hz | 220v ac, 400 hz | | sensor open indication | open message | open message | open message | | sensor short indication | short message | short message | short message | | zero check | provided | provided | provided | | cal check | provided | provided | provided | | signal check | provided | provided | provided | | signal reset | provided | provided | provided |
|
 | Junction Boxes For Indian Navy | | |
features - casting material
- protection level- ip 65
- junction box is design in such way that it can be opened from the front side (butterfly screw arrangement) so that screw driver is not required.
- the wiring / rewiring is easily possible on the field
| |
 | Temperature Monitoring System | | |
| GT EXHAUST GAS Temperature Indication & Alarm System to Measure & Control Temperature of GT
| For Indicator And Alarm Module |
| | Input Sensor | Thermocouple (XA) | | Range | 0°C To 800°C | | Display | 31/2 DIGIT !4" Seven Segment 1/2" size super bright LED type (4digit) | | Accuracy | +/-0.5%FSD, +/-1 digit. | | Resolution | 1°C | | Room Temperature Compensation | Automatic (Self Compensated) | | Terminal | Phonix terminal Strip. | | Supply | 127VAC+/-10%,50Hz. | | Alarm Output | Single relay with 2-change over potential free contact (NC-C-NO) | | Alarm Relay Contact | 5AMP, AC resistive | | Check switch | To check internal calibration | | For Sensor |
| | Type TC | Thermocouple (XA) | | value | 100°C-4.1mV. | | Material | Chromel Alumel +/- | | Accuracy | 0.50% |
|
 | Temperature Monitoring & Singaling | | |
Temperature Scanners
| Input | rtdpt 100 din 43760 | | Display | 4 display - 3! 4 digit 1/2" for parameter |
| 2 display -%n size for channel | | Range | 0°cto125°c | | Resolution | 0. 1°c | | Accuracy | +/-0. 5% fsd,+/-1 digit | | Scan time | 1-10 second (setting is inside the instrument) | | Sensor | pt100rtd | | Sensor open | indicate -1 | | Indicator |
|
Alarm singaling unit
| Input | rtd pt100 din 43760 | | display | : 3/4 digit seven segmented red led |
| super bright | | Range | 0°cto125°c | | Resolution | 0. 1°c | | Accuracy | +/-0. 5% fsd, +/-1 digit indication | | Sensor | pt 100 rtd | | Alarm contact | potential free contact (nc-c-no) two |
| changeover contact | | Alarm relay | 5 amp at 230 vac | | Terminal | phonix 2. 5sq. Mm. Terminals | | Supply | 127v ac, +/-10%. 50 hz | | Alarm signal | for each module individual set table throughout the range | | |
 | GT Gear Box Temperature Scanner | | |
| | Input | RTD PT100 DIN 43760 | | Display | 1) 4 Display - 31/2 Digit 1/2" For Parameter |
| 2) 2 Display -Yi" size for channel | | Range | 0°CTo125°C | | Accuracy | +/-0.5% FSD,+/-1 Digit. | | Scan Time | 1-10 Second (Setting is inside the | | Sensor | PT 100 RTD | | Indicator | Indicate -1 | |
 | Remote Monitoring System | | |
Gas turbine generator we also offer gtg exhaust gas temperature control & monitoring that are basically designed for electrical furnaces, ovens and allied electrical heating system that can be used by the oems. Our range is manufactured by using qualitative raw material as per auto-cad drawing. Besides, these are duly powder coated and are available in various sizes . | |
 | Temperature Scanner For Gas Turbine | | |
| Temperature Scanner For Gas Turbine For SNF Class Warships. | No's Of Channel | 6 | | Selection | Auto or Manual | | Display | 4 Display - 3V& Digit 1/2" For Parameter (Temperature) | | | 2 Display -!4" size for channel | | Range | 0°Cto125°C | | Accuracy | +/-0.5% FSD, +/-1 Digit indication | | Resolution | o.rc | | Sensor | PT 100RTD - 3 wire system | | Scan Time | 1-10 Sec (Setting is inside the instrument) | |
 | Thermo Sensor | | |
| Available in various specifications and level of accuracy, these thermo sensor are acknowledged for its durability, robustness, light weight, high performance, low maintenance and a host of other features. Procured under the strict vigil of our professionals, these are offered at economical prices. | |
 | Junction Box | | |
| We offer a wide range of qualitative Junction Box. We make use of best quality raw materials to manufacture Junction Box so that there is no concession in its quality. Highly appreciated for its industrial applications these are used to store and protect excess fiber optic cable or to provide a cable access point. |
 | Battery Temperature Monitoring System | | |
|
| CAKT-06 | | 1 | Channels | 12Nos, | | 2 | Range | 0-1 M°C | | 3 | Accuracy | 0.5% Of FSD + 1 Digit | | 4 | Sensor | 3 Wire PT-46 | | 5 | Scan Time | Adjustable 1 - 20 Sec. | | 6 | Display | 4 Digit For Parameter 2 Digit For Channel 2 Digit For Function | | 7 | Alarm | Individual Alarm | | 8 | Alarm Contacts | NC-C-No Contact Common For All Channel | | 9 | Alarm Indicator | One LED for Each Channel | | 10 | Power Supply | 220VAC,400Hz | | 11 | Sensor Open Indication | Open Message | | 12 | Sensor Short Indication | Short Message | | 13 | Zero Check | Provided | | 14 | Cal Check | Provided | | 15 | Signal Check | Provided | | 16 | Signal Reset | Provided | | 17 | Output | Common Relay | | |
 | Diesel Auxilary Temperature Monitoring System | | |
|
|
| CAKT-05 | | 1 | Channels | 06 Nos. | | 2 | Range | o-ioo°c | | 3 | Accuracy | 0.5%OfFSD±l Digit | | 4 | Sensor | 3 Wire PT-46 | | 5 | Scan Time | Adjustable 1 -20 Sec. | | 6 | Display | 4 Digit For Parameter 2 Digit For Channel 2 Digit For Function | | 7 | Alarm | Individual Alarm | | 8 | Alarm Contacts | NC-C-NoContact | | 9 | Alarm Indicator | Common For All Channel | | 10 | Power Supply | 127V AC, 50Hz | | 11 | Sensor Open Indication | Open Message | | 12 | Sensor Short Indication | Short Message | | 13 | Zero Check | Provided | | 14 | Cal Check | Provided | | 15 | Signal Check | Provided | | 16 | Signal Reset | Provided | | 17 | Output | Common Relay | |
 | Shafting And Bearing Temperature Monitoring System | | |
|
| CAKT-02 | | 1 | Channels | 24 Nos. | | 2 | Range | 0-100°C | | 3 | Accuracy | 0J%OTFSD±I Digit | | 4 | Sensor | 3 Wire PT-46 | | 5 | Scan Time | Adjustable 1 - 20 Sec. | | 6 | Display | 4 Digit For Parameter 2 Digit For Channel 2 Digit For Function | | 7 | Alarm | ndividual Alarm | | 8 | Alarm Contacts | NC-C-NoContact | | 9 | Alarm Indicator | One lead for each | | 10 | Power Supply | 220V AC 400Hz | | 11 | Sensor Open Indication | Open Message | | 12 | Sensor Short Indication | Short Message | | 13 | Zero Check | Provided | | 14 | Cal Check | Provided | | 15 | Signal Check | Provided | | 16 | Signal Reset | Provided | | 17 | Output | common relay | | |
 | Temperature Scanner For Indian Navy | | |
| Item Code: TAK-011-03 - Function The TAK-011 system is designed for selective measurement of Temperature and single position signaling of present value of measure Temperature of the point under check on main diesel engine. Two in no such system ( one each for one engine) are fitted onboard a submarine.
- Operating Principle It utilities the compensating method of measuring the E.M.F. produced by the Thermocouples.
- The following 9 points of diesel engine are monitored by the TAK —till system:-(a) Point no 1 to Point no 6 are for 6 in no cylinders (b) Point no 7 is for Upper header (c) Point no 8 is for Lower header (d) Point no 9 is for After turb.
- Units TAK —011 system consists of following units:-(a) Auto compensator (b) Push button selector switch (c) Connection box (d) Thermoelectric temperature transducer
- Technical description are given below
| Power Supply | 127V 50 HZ 1<D | | Power Consumed | Not to exceed 10 VA ( Cos O not less than 0.8) | | Measuring Range | 0to 800°C | | Maximum error | Not exceeding 1% of the upper measuring limit. | | No. of spare points | 9 | | No of spare points | 3 | | Ambient temperature | 0 to 50°C and relative air humidity up to 98 |
| Sr. No. | DESCRIPTION | PILNO. | | 1 | THERMOCOUPLE | 8040-231-41 | | 2 | THERMOCOUPLE | 8043-261-20 | | 3 | THERMOCOUPLE | 8040-231-39 | | 4 | THERMOCOUPLE | 8040-231-51 | | 5 | THERMOCOUPLE | 8040-231-27 | | 6 | THERMOCOUPLE | 8040-231-75 | |
 | Monitoring & Alarm System With Sensor | | |
Magazine Temperature Monitoring & Alarm System With Sensor - Temperature range controlled by the instrument: 0 to 100'c.
- Set-point is adjusted by Keyboard, which is provided on the backside of the front door.
- Supply: I27VAC, 50Hz
- Power Consumption: Not greater than 25VA with cos 5 not less than 0.6
- Relay contact which are connected to annunciator 5 A 230 VAC Resistive
- The length of connection system line between thermometer (RIM) and measuring unit (Junction Box) and is not greater than 30m and that between junction box and measuring instrument was I50m.
- The instrument will operate continuously for period of 3000hrs without direct local maintenance as well as intermittently with unlimited amount of switching.
- Intervals between operation period can be used for making replacement trueing and cleaning
- Signaling error at set-point is not greater than ±1.5"c
- Operation error of the instrument with thermometer error considers is not greater than ±2.5°c. .
- Instrument accuracy is not influenced by the following variation of the supply voltage and frequency. a)Continuous variation: Voltage± I 0%, Frequency ±2.5% b)Repeated short term variation c)Voltage from minus 13 to plus 8% d)Frequency from minus 4 to plus 3.5 %
- Electric resistance of instruments circuits against case and against each other will be 20meg at 25°c±10°c
- The enclosure of the instrument is of IP-65 type.
- The instrument has relay contact of Output (Potential free) which are given to annunciator.
- The instrument has auto manual switch to stop scanning of the channel at required stage
- The instrument has provision to check TIC ground and TIC open provision on front panel.
- The instrument has provision of checking front panel Led and display with signal check switch.
- The individual alarm will be indicated by coloured LEI) mounted on the front panel.
- Sixteen relay output has been provided for sixteen groups.
- There are total 72 channel i.e. 72 location of T/C, which is divided into 16 groups.
- There is also provision of low and high alarm set point with the help of Keyboard
- The channel number is indicated by 2 seven segment display.
- The parameter is indicated by 2 seven segment display.
- The temperature is indicated by 4 seven segment display
| |
|