Anadig SystemAnadig System

Quick Search

Home

About Us

Our Products

Contact Us

Enquiry

Instrumentation For Indian Navy

Share: FacebookTwitterStumble
Anadig Systems” manufacture and export Indigeneous anadig make Engine Room Instrumentation for EKM submarines & War Ships.


Engine Room Instrumentation

Engine Room Instrumentation

Indigenous and dig make engine room instrumentation for ekm submarine

cakt - 02 for shafting and bearing temperature monitoring system
cakt - 05 for diesel auxiliary temperature monitoring system
cakt - 06 for battery temperature monitoring system

 


cakt -02 cakt-05 cakt-06
channels 24 nos 06 nos 12 nos
range 0-100ºc 0-100° c 0-100° c
accuracy 0. 5% of fsd ±1 digit 0. 5% of fsd ±1 digit 0. 5% of fsd ±1 digit
sensor 3 wire pt - 46 3 wire pt - 46 3 wire pt - 46
scan time adjustable 1-20 sec adjustable 1 - 20 sec adjustable 1 - 20 sec
display 4 digit for parameter
2 digit for channel
2 digit for function
4 digit for parameter
2 digit for channel
2 digit for function
4 digit for parameter
2 digit for channel
2 digit for function
alarm individual alarm individual alarm individual alarm
alarm contacts nc - c - no contact common for all channel nc - c - no contact common for all channel nc - c - no contact common for all channel
alarm indication one led for each channel one led for each channel one led for each channel
power supply 220v ac, 400 hz 127v ac, 50 hz 220v ac, 400 hz
sensor open indication open message open message open message
sensor short indication short message short message short message
zero check provided provided provided
cal check provided provided provided
signal check provided provided provided
signal reset provided provided provided


Send Enquiry

Junction Boxes For Indian Navy

features
  •  casting material
  •  protection level- ip 65
  •  junction box is design in such way that it can be opened from the front side (butterfly screw arrangement) so that screw driver is not required.
  • the wiring / rewiring is easily possible on the field
Junction Boxes For Indian Navy

Send Enquiry

Temperature Monitoring System

Temperature Monitoring System

GT EXHAUST GAS  Temperature Indication & Alarm System to Measure & Control Temperature of GT

For Indicator And Alarm Module
Input Sensor Thermocouple (XA)
Range 0°C To 800°C
Display 31/2 DIGIT !4" Seven Segment 1/2" size super bright LED type (4digit)
Accuracy +/-0.5%FSD, +/-1 digit.
Resolution 1°C
Room Temperature Compensation Automatic (Self Compensated)
Terminal Phonix terminal Strip.
Supply 127VAC+/-10%,50Hz.
Alarm Output Single relay with 2-change over potential free contact (NC-C-NO)
Alarm Relay Contact 5AMP, AC resistive
Check switch To check internal calibration
For Sensor
Type TC Thermocouple (XA)
value 100°C-4.1mV.
Material Chromel Alumel +/-
Accuracy 0.50%

Send Enquiry

Temperature Monitoring & Singaling

Temperature Scanners

Input rtdpt 100 din 43760
Display 4 display - 3! 4 digit 1/2" for parameter

2 display -%n size for channel
Range 0°cto125°c
Resolution 0. 1°c
Accuracy +/-0. 5% fsd,+/-1 digit
Scan time 1-10 second (setting is inside the instrument)
Sensor pt100rtd
Sensor open indicate -1
Indicator


Alarm singaling unit

Input rtd pt100 din 43760
display : 3/4 digit seven segmented red led

super bright
Range 0°cto125°c
Resolution 0. 1°c
Accuracy +/-0. 5% fsd, +/-1 digit indication
Sensor pt 100 rtd
Alarm contact potential free contact (nc-c-no) two

changeover contact
Alarm relay 5 amp at 230 vac
Terminal phonix 2. 5sq. Mm. Terminals
Supply 127v ac, +/-10%. 50 hz
Alarm signal for each module individual set table throughout the range
Temperature Monitoring & Singaling

Send Enquiry

GT Gear Box Temperature Scanner

GT Gear Box Temperature Scanner

Input RTD PT100 DIN 43760
Display 1) 4 Display - 31/2 Digit 1/2" For Parameter

2) 2 Display -Yi" size for channel
Range 0°CTo125°C
Accuracy +/-0.5% FSD,+/-1 Digit.
Scan Time  1-10 Second (Setting is inside the
Sensor PT 100 RTD
Indicator Indicate -1

Send Enquiry

Remote Monitoring System

Gas turbine generator

we also offer gtg exhaust gas temperature control & monitoring that are basically designed for electrical furnaces, ovens and allied electrical heating system that can be used by the oems. Our range is manufactured by using qualitative raw material as per auto-cad drawing. Besides, these are duly powder coated and are available in various sizes .

Remote Monitoring System

Send Enquiry

Temperature Scanner For Gas Turbine

Temperature Scanner For Gas Turbine

Temperature Scanner For Gas Turbine For SNF Class Warships.

 

No's Of Channel

6

Selection

Auto or Manual

Display

4 Display - 3V& Digit 1/2" For Parameter (Temperature)

 

2 Display -!4" size for channel

Range

0°Cto125°C

Accuracy

+/-0.5% FSD, +/-1 Digit indication

Resolution

o.rc

Sensor

PT 100RTD - 3 wire system

Scan Time

1-10 Sec (Setting is inside the instrument)

 

Send Enquiry

Thermo Sensor

Available in various specifications and level of accuracy, these thermo sensor are acknowledged for its durability, robustness, light weight, high performance, low maintenance and a host of other features. Procured under the strict vigil of our professionals, these are offered at economical prices.
Thermo Sensor

Send Enquiry

Junction Box

Junction Box

We offer a wide range of qualitative Junction Box. We make use of best quality raw materials to manufacture Junction Box so that there is no concession in its quality. Highly appreciated for its industrial applications these are used to store and protect excess fiber optic cable or to provide a cable access point.

Send Enquiry

Battery Temperature Monitoring System



CAKT-06
1 Channels 12Nos,
2 Range 0-1 M°C
3 Accuracy 0.5% Of FSD + 1 Digit
4 Sensor 3 Wire PT-46
5 Scan Time Adjustable 1 - 20 Sec.
6 Display 4 Digit For Parameter 2 Digit For Channel 2 Digit For Function
7 Alarm Individual Alarm
8 Alarm Contacts NC-C-No Contact Common For All Channel
9 Alarm Indicator One LED for Each Channel
10 Power Supply 220VAC,400Hz
11 Sensor Open Indication Open Message
12 Sensor Short Indication Short Message
13 Zero Check Provided
14 Cal Check Provided
15 Signal Check Provided
16 Signal Reset Provided
17 Output Common Relay
Battery Temperature Monitoring System

Send Enquiry

Diesel Auxilary Temperature Monitoring System

Diesel Auxilary Temperature Monitoring System



CAKT-05
1 Channels 06 Nos.
2 Range o-ioo°c
3 Accuracy 0.5%OfFSD±l Digit
4 Sensor 3 Wire PT-46
5 Scan Time Adjustable 1 -20 Sec.
6 Display 4 Digit For Parameter 2 Digit For Channel 2 Digit For Function
7 Alarm Individual Alarm
8 Alarm Contacts NC-C-NoContact
9 Alarm Indicator Common For All Channel
10 Power Supply 127V AC, 50Hz
11 Sensor Open Indication Open Message
12 Sensor Short Indication Short Message
13 Zero Check Provided
14 Cal Check Provided
15 Signal Check Provided
16 Signal Reset Provided
17 Output Common Relay

Send Enquiry

Shafting And Bearing Temperature Monitoring System



CAKT-02
1 Channels 24 Nos.
2 Range 0-100°C
3 Accuracy 0J%OTFSD±I Digit
4 Sensor 3 Wire PT-46
5 Scan Time Adjustable 1 - 20 Sec.
6 Display 4 Digit For Parameter 2 Digit For Channel 2 Digit For Function
7 Alarm ndividual Alarm
8 Alarm Contacts NC-C-NoContact
9 Alarm Indicator One lead for each
10 Power Supply 220V AC 400Hz
11 Sensor Open Indication Open Message
12 Sensor Short Indication Short Message
13 Zero Check Provided
14 Cal Check Provided
15 Signal Check Provided
16 Signal Reset Provided
17 Output common relay
Shafting And Bearing Temperature Monitoring System

Send Enquiry

Temperature Scanner For Indian Navy

Temperature Scanner For Indian Navy

Item Code: TAK-011-03

  • Function The TAK-011 system is designed for selective measurement of Temperature and single position signaling of present value of measure Temperature of the point under check on main diesel engine. Two in no such system ( one each for one engine) are fitted onboard a submarine.
  •  Operating Principle It utilities the compensating method of measuring the E.M.F. produced by the Thermocouples.
  • The following 9 points of diesel engine are monitored by the TAK —till system:-(a) Point no 1 to Point no 6 are for 6 in no cylinders (b) Point no 7 is for Upper header (c) Point no 8 is for Lower header (d) Point no 9 is for After turb.
  •  Units TAK —011 system consists of following units:-(a) Auto compensator (b) Push button selector switch (c) Connection box (d) Thermoelectric temperature transducer
  • Technical description are given below

Power Supply 127V 50 HZ 1<D
Power Consumed Not to exceed 10 VA ( Cos O not less than 0.8)
Measuring Range 0to 800°C
Maximum error Not exceeding 1% of the upper measuring limit.
No. of spare points 9
No of spare points 3
Ambient temperature 0 to 50°C and relative air humidity up to 98


Sr.

No.

DESCRIPTION

PILNO.

1

THERMOCOUPLE

8040-231-41

2

THERMOCOUPLE

8043-261-20

3

THERMOCOUPLE

8040-231-39

4

THERMOCOUPLE

8040-231-51

5

THERMOCOUPLE

8040-231-27

6

THERMOCOUPLE

8040-231-75

Send Enquiry

Monitoring & Alarm System With Sensor

Magazine Temperature Monitoring & Alarm System With Sensor

  • Temperature range controlled by the instrument: 0 to 100'c.
  • Set-point is adjusted by Keyboard, which is provided on the backside of the front door.
  • Supply: I27VAC, 50Hz
  • Power Consumption: Not greater than 25VA with cos 5 not less than 0.6
  •  Relay contact which are connected to annunciator 5 A 230 VAC Resistive
  •  The length of connection system line between thermometer (RIM) and measuring unit (Junction Box) and is not greater than 30m and that between junction box and measuring instrument was I50m.
  •  The instrument will operate continuously for period of 3000hrs without direct local maintenance as well as intermittently with unlimited amount of switching.
  •  Intervals between operation period can be used for making replacement trueing and cleaning
  •  Signaling error at set-point is not greater than ±1.5"c
  • Operation error of the instrument with thermometer error considers is not greater than ±2.5°c. .
  • Instrument accuracy is not influenced by the following variation of the supply voltage and frequency. a)Continuous variation: Voltage± I 0%, Frequency ±2.5% b)Repeated short term variation c)Voltage from minus 13 to plus 8% d)Frequency from minus 4 to plus 3.5 %
  •   Electric resistance of instruments circuits against case and against each other will be 20meg at 25°c±10°c
  • The enclosure of the instrument is of IP-65 type.
  • The instrument has relay contact of Output (Potential free) which are given to annunciator.
  • The instrument has auto manual switch to stop scanning of the channel at required stage
  •   The instrument has provision to check TIC ground and TIC open provision on front panel.
  • The instrument has provision of checking front panel Led and display with signal check switch.
  •  The individual alarm will be indicated by coloured LEI) mounted on the front panel.
  •  Sixteen relay output has been provided for sixteen groups.
  • There are total 72 channel i.e. 72 location of T/C, which is divided into 16 groups.
  • There is also provision of low and high alarm set point with the help of Keyboard
  •  The channel number is indicated by 2 seven segment display.
  •  The parameter is indicated by 2 seven segment display.
  •  The temperature is indicated by 4 seven segment display
Monitoring & Alarm System With Sensor

Send Enquiry

Product
Showcase

View all our products / services as a slide show.

play now



Contact Us

Mr. V. V. Masurekar (Director)
B - 214, Shreyas Industrial Estate, Near Jay Coach, Goregaon East
Mumbai, Maharashtra - 400 063, India
Telephone:  +(91)-(22)-65706237/ 64520106

Contact via E-mail

Contact via Mobile

Contact via SMS

Home  |  About Us  |  Our Products   |  Site Navigation  |  Contact Us  |  Enquiry

Member IndiaMART.com © Anadig System. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile: