Anandha Jothi Industries Anandha Jothi Industries

Relay Test Kit

Secondary Injection Kit 40 A

Transformer Test Board

Circuit Breaker Time Interval

Frequency Test

Energy Meter Test Kit

Contact Resistance Meter

Oil Test Kit

Primary Injection Kit

DC Power Pack

CT Knee Point Voltage Tester

High Voltage Test Kit

Cable Tester

Breaker Tester

Hipot Tester

Micro OHM Meter

CT Tester

DC Power Source

Primary Injection Tester

AC/DC High Voltage Test-Kit - (Hi-Pot Test Kit)

C.T Polarity Tester

Hi Pot Kit

Electrical & Electronic Testing Equipments

Transformer-Oil Break-Down Voltage Test-Kit

DC HV Tester


Electronic Testing Equipment

Share: FacebookTwitterStumble

We are a leading Manufacturer & Supplier of Electronic Testing Equipment such as Relay Test Kit, Secondary Injection Kit 40 A, Transformer Test Board, Electrical & Electronic Testing Equipments, Circuit Breaker Time Interval, Frequency Test and many more items from India.

Relay Test Kit

Enlarge View

Relay Test Kit

 Features:

  • Single Kit with two units

  • Two separate inputs, five outputs

  • Test outputs available:

                  unit – I  :  0 to100 A AC, 0 to 240 volts AC

                  unit – II:   0 to1 A AC, 0 to 240

                              volts AC and aux 0 to 240 volts DC   

  • Panel with clear and easy to follow legend.

  • Built in Timer for testing IDMT relays or circuit breakers.

  • Overload protection.

  • Independent Digital readouts of current, voltage and time.

The kits can be for all types of relays (current and voltage relays) except MOH & Distance relays


Applications:

Suitable for checking protective devices such as all types of relays:

1.Over current relay

2. IDMT over current relay,

3.Under current relay,

4.Earth fault relay,

5 Over Voltage relay.

6. Under voltage relay,

7.Differential relay,

8.Negative sequence relay,

9.Motor protection relay,

10.Auxilary relay,

11. Thermal relay,

12.Time delay relay.

13.Single Pole circuit Breaker timing and meters on installation and at regular services.

Quick detection of faulty or incorrectly adjusted devices during routine current/voltage injection tests. Built in timer to measure the operating time.

 





Secondary Injection Kit 40 A

Portable over Current Relay Test KIT - Unit – I

S.No. Model RLY – 786
1 SUPPLY VOLTAGE 230 Volts , 50 Hz, (± 10%), AC Single Phase supply through Toggle switch & Control Fuse for Units 1 & 2.
2 OUTPUT 1. Variable current Application 0 – 40A AC
2. For voltage, the Variac output is connected to variable voltage output 0 – 230 V AC with fuse.
3. Separate current output terminals and separate voltage output terminals are provided
(At one time either current or voltage circuit will be connected through a Toggle Switch)
3 CONTROLS 1. 1ST Unit with Push Button Control Only. When the ON/OFF push button is operated, all outputs will be connected to the output connectors
2. 2nd unit with Push Button Control & By-Pass Switch
4 CURRENT OUTPUT Output : 0 – 40A – 25A – 10A - 5A – 1A
Each of these outputs has a separate terminal referred to one common terminal.
Each current output terminal is for 400 VA capacity, except 1A output which is for 250 VA capacity
5 VOLTAGE OUTPUT  0-230 V AC / 2A – Variable voltage output through fuse units,Separate pair of test terminals is provided
6 RATING Continuous (3min ON / 10 Min. OFF)
7 AMMETER 3 ½ Digit, 12mm LED type. Accuracy: ± 1% (Direct reading 0 – 40 A)
For current ranges of 1A, 5A, 10A, 25A and 40A AC, readings can be noted directly from the digital ammeter.
8 VOLTMETER 3 ½ Digit, 12mm LED type. Accuracy:± 1 % (Common meter for measurement of Unit-1 & Unit-2 AC & Unit-2 DC output through a 3 position selector switch)
a. an be read at a time.




Secondary Injection Kit 40 A

Enlarge View

Transformer Test Board

Enlarge View

Transformer Test Board

We are among the reputed organizations engaged in manufacturing, supplying and exporting Power Transformers. All these transformers are manufactured in tandem with IEEE standards by using latest machines and optimum quality material. In order to offer premium quality transformers to our clients, our experts examine these transformers on variegated parameters of quality and performance, before the final delivery.

 

Applications:

 

  • Electricity Board
  • Industrial Purpose
  • Domestic Transformers
  • Consumer Transformers
  • Wind Mill Power Transmission

 

Note:

 

  • Specifications are subject to change without notice
  • All electrical parameters are tested with Agilent/HP 4284 A LCR / power analyzer yokogawa





Circuit Breaker Time Interval

OVER VIEW

·         Latest  version of AJI Series of Time Interval Meter. 

·         Single instrument can test all types of CBs - LV, HV & EHV.

·         Lightweight, housed in rugged case enhancing transport worthiness.  Inbuilt Real Time Clock 

FEATURES·         CB operated through instrument facilitating accurate measurement.   Comparison possible with Manufacturer's test result by measuring C, O & C-O timings directly in milli-seconds.

·         Saves down time, indicates pole discrepancy as it measures the timing of 3 poles simultaneously.     4 line 20 character backlit LCD display for menu and results.

·         Inbuilt memory to hold results of last 10 tests.       

 

THREE  POLE  TIMER

 

Sl No.

Description

Data

1

Make

ANANDHA  JOTHI

2

Power Supply Input

230V AC ± 15%, 50Hz ± 10%, 1 Phase

3

Out Put         

Time & Mode Selection (Three Pole)

4

No of Channels 

Three pole (Three - digit timer)

5

Operation Modes 

C / O / C-O

6

Time Range 

0 - 999ms

7

Resolution

1ms

8

Accuracy Value

± 0.5% ± 1 Digit

9

Display 

4 line 20 character backlit LCD display

10

Inbuilt Memory 

10 test results

11

Panel Comprising of

a) 4-Position Selector Close/Open & Close/Open for all the three Phases (3NO/NC for checking opening & closing time in  millisecond)

b) NO/NC Test Terminals

c) Reset Push-Button

12

Dimension

430 x 345x160mm

13

Instrument Weight 

6kg

 





Circuit Breaker Time Interval

Enlarge View

Frequency Test

Enlarge View

Frequency Test

We offer our quality conscious customers a wide range of Frequency cum Voltage Generators at very economical prices. Our expertise lies in manufacturing and supplying high performing Voltage Generators that are designed and developed by qualified and experienced industry professionals using advanced manufacturing equipment so as to deliver in them exceptional performance standards. Further, the use of quality components at manufacturing & fabrication stage also ensure in them maximum efficiency as well as high performance.

Specifications:

Input: 230VAC 50Hz

Output:

  • 20 – 200 V AC, (Variable)
  • 30 – 80 Hz (Variable)
  • Common - 63.5,110 V AC, (Constant Voltage 50Hz)

Meters: Frequency

  • Enclosure: Aluminium Powder Coated Box
  • Kit size: 14” x 12” x 8.5”
  • Kit weight: 15 kegs





Energy Meter Test Kit

3 Phase Energy Meter Test Kit Specification

Make : Anandha Jothi 


Model : EMT 115

1.Mains input 440V AC 50 Hz
2.Mains ON/OFF MCB
3.Mains 3 phase indication lamp and etc.

Voltage Output : Selectable voltage mode

  1.  0 – 230 V Variable voltage source each phase

  2. External Phase Shifter

    1. Provision has been provided for external phase shifter

    2. If there is no necessity for shifter, then short the phase shifter connectors (input, output)

    3. A ) BY - Pass Mode

      If by pass - mode is chosen then all voltage output will be directly connected to the output connectors ( * In this option timer is OFF mode )

      B) Control Mode

      Push button control mode is chosen then all voltage output will be connected to the output connectors when the ON/OFF push button is operated

      (* In this option timer is ON mode )

      Current Output

      Variable current application 0 –5 A AC each phase separately (variable current output connected through MCB unit each phase)

       

    4.  

      3 Phase Energy Meter Test Kit Specification

       

       

      1. Metering Reading ( Power Multimeter Measured ) Accuracy

        1. 3 phase voltage

        2. 3 phase current

        3. KW

        4. KWH

        5. KVA

        6. KVAR

        7. PF

        8. HZ


        9. Time interval meter :

        1.  
          1.  
            •  One five digit timer with toggle selector of NO/NC (for checking the opening and closing time) milli second. The timer four position selection for auto ranges ( NO/NC test terminals , reset push buttons etc )

               Milli Seconds: 

              • 999.99 m. Sec

              • 9999.9 m. Sec

              • 99999 Sec

              • The timer will stop on getting the signal from the relay. When the timer stops the output current and voltage will be zero

                Top plate all details reverse engraved plastic sheet

                Enclosure MS powder coated box

                Size 17.5” x 13” x 7.5 ”

                Weight 25 kegs. (Approx.)

                Thanking you and assuring you of our best service at all time.

                 

                 

            • Time interval meter :

               

              One five digit timer with toggle selector of NO/NC (for checking the opening and closing time) milli second. The timer four position selection for auto ranges ( NO/NC test terminals , reset push buttons etc )

               

              Milli Seconds: - 99.999 m. Sec

              A ) BY - PASS MODE

              If by pass - mode is chosen then all voltage output will be directly connected to the output connectors ( * In this option timer is OFF mode )

              B) Control Mode

              Push button control mode is chosen then all voltage output will be connected to the output connectors when the ON/OFF push button is operated

              (* In this option timer is ON mode )

              Current Output

              Variable current application 0 –5 A AC each phase separately (variable current output connected through MCB unit each phase)

               

              3 Phase Energy Meter Test Kit Specification

               

               

              Metering Reading ( Power Multimeter Measured ) Accuracy .5 %

               

      2. External Phase Shifter


 





Energy Meter Test Kit

Enlarge View

Contact Resistance Meter

Enlarge View

Contact Resistance Meter

Specification

·         A radically new design makes CRM the lighte weight  100 A contact resistance meter.

·         Direct display of micro-ohm value without need of manual calculations.

·         Fool-proof connections and repeatability are ensured by specially designed proprietary biting type CK clamps.

·         Supplied with rugged calibrated test lead set suitable for 4 wire measurement.

·         No need to compensate lead resistance as Kelvin's Four wire measurement method is used. 

·         Easy to use - single key operation.

·         Housed in rugged case enhancing transport worthiness.

 

CONTACT RESISTANCE METER (MILLI VOLT DROP TESTER)   0 – 100 Amps

 

Sl No.

Description

Data

1

Input

230 V AC,50 Hz Single Phase

2

Output Current

0-100Amps DC Maximum

3

Current Selection

Selection through Variable (Variac)

4

Capacity

700 VA Max. Output Current.

5

Duty Cycle

3min ON / 5min OFF

6

Volt meter

0-200mV Direct Reading  Digital D.C Mill voltmeter

Provided Press to read push button

7

Ammeter

0-100A D.C Direct Reading digital Ammeter

8

Panel Comprising of

 A )Out put ON / OFF Push Button Controls 

B) Mains Fuse Indication

c) Control Fuses for Protection & Indication

d) Output Current / Input Milli volt terminals





Oil Test Kit

Oil Test Kit offered by us meet specifications viz. IS 6792. These Customized Oil Test Kits are ideally suited for transformer switchgear manufacturing units, repair shops, oil filtering agencies as well as electrical maintenance. Further, these kits are manufactured from tested materials that are obtained from leading suppliers & vendors to ensure maximum efficiency of these Oil Test Sets.

Safety Features:

  • These Oil Test Sets are equipped & designed for testing dielectric strength of insulating oils as per the defined specifications
  • Zero inter locking arrangement
  • Transparent hood (cover) on test cup with a door inters locking micro switch
  • Resin encapsulated H.T. transformer
Construction:
  • In naturally air cooled, portable sheet metal casing (60 KV) models

Optional:

  • Motorized version, to uniform increase output test voltage between 0 - 60KV / 0 – 80 KV / 0 - 100KV @ 2KV / Sec. Approx

Specifications:

  • Input:240V Single Phase, 50Hz. A.C.
  • Output: 0 - 100KV / 0 – 80 / 0 - 60KV center top earthed
Capacity:
  • Indication
  • Mains 'ON' and H.T. 'ON' Lamp
  • Metering
  • 72mm / size back of panel mounting A.C. Voltmeter to monitor output voltage
  • Protection
  • Electronic, fast acting over current tripping device sensing HT current directly
  • ISS reference





Oil Test Kit

Enlarge View

Primary Injection Kit

Enlarge View

Primary Injection Kit

Our expertise lies in successfully meeting the demands of manufacturing and supplying Primary Injection Test Kits that are made in highly advanced manufacturing units by using synthesis of quality materials as well as sophisticated equipment as per international quality standards & production norms. We also ensure that these are offered at cost-effective prices. Further, we also procure materials from well-known vendors & suppliers so as to enhance both quality of customized Injection Kits as well as achieve high level of customer satisfaction.

Following are some of the features & technical specifications of these Test Kits:

Features:

  • Continuous or short time rating
  • Digital panel meters for output Amps
  • Input protection by MCB
  • Rotary switch selection of 1st stage single phase input fine adjustment with single phase
  • 2nd stage 2 phase one phase direct supply another one phase Variac input fine adjustment with single phase
  • Having copper heavy duty bus bars
  • Forced air cooling system
  • Direct reading
  • Front and rear panel protection by hinged lockable doors

Application:

  • CT Primary Injection Test
  • Temperature rise tests on bus bars etc.

Specifications:

  • Input: 220/440V, 50Hz
  • Output: Customized





DC Power Pack

We, offer an extensive range of DC Power Packs. Our team of highly established industry professionals assist us in designing, manufacturing & supplying matchless customized D.C Power Packs. These Portable Power Packs are extensively used in various industries with expertise in offering services based on customer requirements and their specifications. Our range of variable D.C Power Pack is also offered as per customers’ requirements & specification of customers. Our all products under go for quality testing of D.C Power Packs as to ensure clients’ satisfaction across the world. Some of the Technical Specifications are given below.

Technical Specifications:

  • Input : 230 V AC, 50 Hz Single Phases
  • Output : 0 – 240 V DC Continuously variable with
  • HV Selection: Selection through Variac
  • Capacity 50 A Max.
  • Volt Meter: Scale reading 0- 240V DC.
  • Protection : mains &out put
  • Indications : Mains ON indication
  • Enclosure MS powder coated box





DC Power Pack

Enlarge View

CT Knee Point Voltage Tester

Enlarge View

CT Knee Point Voltage Tester

CT Knee Point Voltage Tester manufactured by us is a HV Test Kit (AC/DC) that caters extensively to industrial requirements of the clients. These test kits are durable as well as offer best results. Hence, customers prefer these high voltage test skit to meet their specific needs. Further, we ensure that all electrical testing equipment are available at cost effective price range with commitment of timely delivery.

Specifications:

  • Input: 230 V AC, 50 Hz Single Phases
  • Output: 0 – 5 KV AC Continuously variable with (Earth & potential)
  • HV Selection: Selection through Variac 0 – 5KV AC.
  • Capacity: 50.0 mA Max. Output Current.
  • Volt Meter: Scale reading 0-5KV AC. Digital meter
  • HV Selection: 0 - 5 KV AC. Through Variac
  • Over load Trip: Selector depending up on the current
  • Switch position: 100mA Over load Trip selection, 200 mA Over load Trip selection, 300mA Over load Trip selection & 500 mA Over load Trip selection
  • Indications: HV ON indication
  • HV fail indication
  • Zero inter lock indication
  • Duration – 3 minutes ON / 10 minutes OFF





High Voltage Test Kit

HV Test Kit Specification (0- 70KV AC) & 80 KV DC

1. Input - 230 V AC 50 Hz

2. Output - HV Test Kit (0- 70KV AC) & 80 KV DC

3.Duration – 3 minutes ON / 10 minutes OFF

4. Dual protected HV over current: 10 mA, 25 mA and 50 mA AC

Tripping selection : 5 mA, 10 mA and 20 mA DC

5. HV ON indication

6. HV fail indication

7. Zero inter lock indication

8. Earth fails indication

9. Earth failure Output cut OFF control

10. Polarity change (Phase neutral) cut OFF control

11. 0 - 50 mA AC / DC digital milliamps meter

12. HV 0 –70.0 KV AC/ 0 -80 KV DC digital meter

13. Earth rod (discharge rod)

14. High tensile powder coated fiber box

The top plate, reverse side engraved with all Details

Enclosure MS powder coated box

Transformer size : 16” x 14” x 12”  Weight               : 41 kegs. Approx.

Control unit size : 13.5” x 11.5” x 8.5” weight               : 13 kegs. Approx.


HV Test Kit Specification 0 - 30 KV AC /50 mA & 40 KV DC / 25mA

 1. Input - 230 V AC 50 Hz

2. Output - 0 - 30 KV AC /50 mA & 40 KV DC / 25mA

3.Duration – 3 minutes ON / 10 minutes OFF

4. Dual protected HV over current: 10 mA, 25 mA, and 50 mA AC

Tripping selection 5 mA, 10 mA, and 20 mA DC

5. HV ON indication

6. HV fail indication

7. Zero inter lock indication

8. Earth fail indication

9. Earth failure Output cut OFF control

10. Polarity change (Phase neutral) cut OFF control

11. 0 - 50 mA AC/DC digital milliamps meter

12. HV 0 – 30.0 KV AC/0 – 40.0 KV DC digital meter

13. Earth rod (discharge rod)

14. High tensile powder coated MS box

 The top plate, reverse side engraved with all Details

Enclosure MS powder coated box

Transformer size : 13.5” x 11.5” x 8.5” weight : 25 kegs . Approx.

Control unit size : 13.5” x 11.5” x 8.5” weight : 12 kegs . Approx.

 





High Voltage Test Kit

Enlarge View

High Voltage Test Kit

Enlarge View

High Voltage Test Kit

We offer extensive range of AC/DC High Voltage testing equipments are necessary for any
LV/HV/EHV substation equipment testing, Panel Testing, Cable Testing etc. Application of high
voltage or rated voltage to the test object exposes any weak-point in the insulation quality.
HV Breakdown testing or High-Voltage Proof testing is one of the most commonly used methods
to check insulation levels that any equipment can sustain, without a flash-over taking place.We
design and manufactureadvanced High-Voltage test equipment (also called Hi-pot Testers) that
are used by utilities and industries worldwide to guarantee a shock-proof life. Our Hi-pot Test-Kits
are of less weight & small in size, available in India. We have a very wide range of Hi-pot Test
equipments ranging from 100V to 100kV, available in powerratings ranging from 100VA to 100KVA.
The control panel can be customized fordifferent applications as per customer needs, while the HV system measurementaccuracy and Operator and Equipment safety remains uncompromised.








Cable Tester

APPLICATION OF DC HIGH VOLTAGE TEST KIT

Portable DC High Voltage Test Set is used for testing the underground cable for knowing the condition of cable-leakage at High Voltage. The unit comes with digital meters for easy readability with a test terminal.
(cable testing) 





Cable Tester

Enlarge View

Breaker Tester

Enlarge View

Breaker Tester

In response to demands for safer and more convenient methods of training & demonstrating circuit breaker testing, weis has developed the ss100 portable switchgear simulator. It is used to simulate the basic functions of a power breaker with operate coils, timing contacts and motion sensor.





Hipot Tester

Application Of Ac High Voltage Test Kit
High Voltage testing equipments are necessary for any LV/HV/EHV substation
equipment testing, Panel Testing, Cable Testing etc. Application of high voltage orrated voltage to the test object exposes any weak-point in the insulation quality.HV Breakdown testing or High-Voltage Proof testing is one of the most commonlyused methods to check insulation levels that any equipment can sustain, without aflash-over taking place. At Anandha Jothi Industries, we design and manufactureadvanced High-Voltage test equipment (also called Hi-pot Testers) that are used byutilities and industries worldwide to guarantee a shock-proof life. Our Hi-pot Test-Kits are of less weight & small in size, available in India. We have a very wide rangeof Hi-pot Test equipments ranging from 100V to 100kV, available in power ratingsranging from 100VA to 100KVA. The control panel can be customized for differentapplications as per customer needs, while the HV system measurement accuracyand Operator and Equipment safety remains uncompromised.
Application Of Dc High Voltage Test Kit
Portable DC High Voltage Test Set is used for testing the underground cable for
knowing the condition of cable-leakage at High Voltage. The unit comes with digitalmeters for easy readability with a test terminal.






Hipot Tester

Enlarge View

Micro OHM Meter

Enlarge View

Micro OHM Meter

MICRO OHM METER    0 – 100 Amps

Sl No.

Description

Data

1

Input

230 V AC,50 Hz Single Phase

2

Output Current

0-100Amps DC Maximum

3

Current Selection

Selection through Variable (Variac)

4

Capacity

700 VA Max. Output Current.

5

Duty Cycle

3min ON / 5min OFF

6

Volt meter

0-200mV Direct Reading  Digital D.C Mill voltmeter

Provided Press to read push button

7

Ammeter

0-100A D.C Direct Reading digital Ammeter

8

Panel Comprising of

 A )Out put ON / OFF Push Button Controls 

B) Mains Fuse Indication

c) Control Fuses for Protection & Indication

d) Output Current / Input Milli volt terminals





CT Tester

Checking the Polarity of Current Transformers The Polarity of current transformers is extremely important. Just like a battery, a current transformer too has a polarity. The polarity determines the direction of the secondary current in relation to the primary current, Wrong connection of the current transformers can cause false operation of the protection relays. Hence, it is vital to ensure that the current transformers are connected with the correct polarity.





CT Tester

Enlarge View

DC Power Pack

Enlarge View

DC Power Pack

Our company has gained name in providing good quality DC Power packs with combination of various flows, pressure, options for unloading and with options of various 12V, 24V DC motors.





DC Power Source

Our clients can avail from us, a quality assured range of DC Power Source that is a universal current and voltage source. Used for testing, setting and calibrating electricity meters, our DC Power Source is a device that helps in low energy consumption.





DC Power Source

Enlarge View

Primary Injection Tester

Enlarge View

Primary Injection Tester

Our expertise lies in successfully meeting the demands of manufacturing and supplying Primary Injection Test Kits that are made in highly advanced manufacturing units by using synthesis of quality materials as well as sophisticated equipment as per international quality standards & production norms. We also ensure that these are offered at cost-effective prices. Further, we also procure materials from well-known vendors & suppliers so as to enhance both quality of customized Injection Kits as well as achieve high level of customer satisfaction.

Following are some of the features & technical specifications of these Test Kits:

Features:

  • Continuous or short time rating
  • Digital panel meters for output Amps
  • Input protection by MCB
  • Rotary switch selection of 1st stage single phase input fine adjustment with single phase
  • 2nd stage 2 phase one phase direct supply another one phase Variac input fine adjustment with single phase
  • Having copper heavy duty bus bars
  • Forced air cooling system
  • Direct reading
  • Front and rear panel protection by hinged lockable doors

Application:

  • CT Primary Injection Test
  • Temperature rise tests on bus bars etc.

Specifications:

  • Input: 220/440V, 50Hz
  • Output: Customized





AC/DC High Voltage Test-Kit - (Hi-Pot Test Kit)

Application of ac high voltage test kit
 High Voltage testing equipments are necessary for any LV/HV/EHV substation
equipment testing, Panel Testing, Cable Testing etc. Application of high voltage orrated voltage to the test object exposes any weak-point in the insulation quality.HV Breakdown testing or High-Voltage Proof testing is one of the most commonlyused methods to check insulation levels that any equipment can sustain, without aflash-over taking place. At Anandha Jothi Industries, we design and manufactureadvanced High-Voltage test equipment (also called Hi-pot Testers) that are used byutilities and industries worldwide to guarantee a shock-proof life. Our Hi-pot Test-Kits are of less weight & small in size, available in India. We have a very wide rangeof Hi-pot Test equipments ranging from 100V to 100kV, available in power ratingsranging from 100VA to 100KVA. The control panel can be customized for differentapplications as per customer needs, while the HV system measurement accuracyand Operator and Equipment safety remains uncompromised.
Application of dc high voltage test kit
 Portable DC High Voltage Test Set is used for testing the underground cable for
knowing the condition of cable-leakage at High Voltage. The unit comes with digitalmeters for easy readability with a test terminal.





AC/DC High Voltage Test-Kit - (Hi-Pot Test Kit)

C.T Polarity Tester

Enlarge View

C.T Polarity Tester

Checking the Polarity of Current Transformers

The Polarity of current transformers is extremely important. Just like a battery, a current transformer too has a polarity. The polarity determines the direction of the secondary current in relation to the primary current.

Wrong connection of the current transformers can cause false operation of the protection relays. Hence, it is vital to ensure that the current transformers are connected with the correct polarity.

A DC source is connected with the positive terminal to P1 and the negative terminal to P2. An analog voltmeter is connected to the secondary terminal of the CT. The positive terminal of the meter is connected to terminal S1 of the CT while the negative is connected to terminal S2.

A contact is momentarily made through the switch. The contact is made for a second and broken. This is important as continuous contact can short-circuit the battery. The momentary make-break contact causes a deflection in the analog multimeter in the positive direction, if the polarity is correct.

If the deflection is negative, it indicates that the polarity of the current transformer is reversed. The terminals S1 and S2 need to be reversed and the test can be carried out.





Hi Pot Kit

Sl No.

Description

Data

1

Input

For all Models

230V/ A.C / 50Hz, Single Phase 

Output

MODELS 

Size & Weight

2

0 - 30 KV AC / 50 mA & 40 KV DC / 25mA 

HV – 30 KV

Tr: 13.5”x11.5”x8.5”/ Wt: 25 kgs .Appx C.Unit : 13.5”x11.5”x8.5”/ Wt: 12 kgs .Appx

0 - 60 KV AC / 50 mA & 75 KV DC / 25mA 

HV – 60 KV

Tr: 18”x18”x12”/ Wt: 41 kgs .Appx C.Unit : 13.5”x11.5”x8.5”/ Wt: 14 kgs .Appx

0 - 70 KV AC / 50mA & 80 KV DC / 25mA

HV – 70 KV

Tr: 18”x18”x12”/ Wt: 45 kgs .Appx C.Unit : 13.5”x11.5”x8.5”/ Wt: 15 kgs .Appx





Hi Pot Kit

Enlarge View

Hi Pot Kit

Enlarge View

Hi Pot Kit

Sl No.

Description

Data



0 - 70 KV AC / 50mA  &                               80 KV DC / 25mA

HV – 70 KV

Tr: 18”x18”x12”/ Wt: 45 kgs .Appx                C.Unit : 13.5”x11.5”x8.5”/ Wt: 15 kgs .Appx               

0 - 30 KV AC / 100 mA &                             40 KV DC / 25mA

HV – 30 KV (C)

Tr: 16”x14”x13”/ Wt: 40 kgs .Appx                C.Unit : 17”x13”x9.5”/ Wt: 15 kgs .Appx               





Hi Pot Kit


Duration (
Switching “ON”/“OFF”)

For all Models

3 minutes “ON” / 10 minutes “OFF”

 

50mAmps Range

100mAmps Range





Hi Pot Kit

Enlarge View

Hi Pot Kit

Enlarge View

Hi Pot Kit

4a

Protection : HV Over Current Tripping  Selection        - A.C                                                      

10 mA/25 mA & 50 mA AC

25mA / 50mA / 75mA &100mA AC





Electrical & Electronic Testing Equipments

We are manufacturer and exporter of Electrical & Electronic Testing Equipments  like Oil Test Kit, Voltage Circuit Breaker, DC Power pack, Primary Injection Kit, Energy Master Test Kit, HV Test Kit which are durable and efficient.





Transformer-Oil Break-Down Voltage Test-Kit

The Dielectric Break-Down Voltage test is an important test to determine the
withstanding capacity of any insulating oil or liquid. Due to continuous
operation, the transformer oil is subjected to degradation or ingress of moisture
and it is necessary to test the insulating oils periodically. BDV test is one of the
most common tests done on all Insulating fluids, but a very critical one.
Breakdown (BDV) test is a test of choice because it takes very less time to conduct
and is a precursor to the condition of the insulating liquid, before carrying out
extensive series of tests. Anandha Jothi Industries offer precision Manual &
Motorised Oil BDV Test sets, suitable for Indoor / Outdoor applications.

Specifications:
Input Voltage-220/230 V Single Phase, 50Hz
Output Voltage-0-60 KV, 0-80 KV, & 0-100 KV (3 Models)
Capicity-0.5 KVA to 1 KVA
Voltage Control-A Variac is used for controlling the output from zero to maximum.
Set Up Transformer-  An Epoxy-moulded Air cooled transformer is used to boost the
voltage to required voltage.
Metering-Voltmeter is provided on LT side, to indicate the secondary output
voltage.
Electrode-Suitable size of electrodes with adjustable gap are provided
Protection- The unit consists of fast acting DC relay provided on LT side to cut
 off the HT supply in case of Flash – Over
Interlock-Zero start interlocking is provided (Top-Door opening type)
Test Cup-A test cup of suitable size made of transparent thermoplastic









DC HV Tester

DC HV Tester

We offer a wide range of DC HV tester.
Send Enquiry


Contact Us
Anandha Jothi Industries
Mr. Mahendran . (Manager)
No. 3/3, Viswanathan, 3rd Cross Street, Dharmaraja Nagar, Karambakkam
Chennai - 600116, Tamil Nadu, India

Contact via E-mail




Member IndiaMART.com © Anandha Jothi Industries. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Contact Us

*Describe Your Requirements in Detail
Remaining Characters: 3500
Your Contact Information
Your Contact Information
*Name:
*Email:
Company:
Website:
*Country:

City:
*Mobile:
*Enter the code: