Product Portfolio
Water Treatment Plants Water Treatment Chemicals Meters Water Treatment Meters Chemiline Make Digital Photoelectric Colorimeter Cl 610 & Cl 620 Chemiline Make Micro Controller Based Photoelectric Colorimeter Cl 660 Chemiline Digit Conductivity Meter Cl 220 Chemiline Digit Conductivity Meter Cl 250 Chemiline Digital Conductivity-TDS Meter Cl 210 Chemiline Digital Conductivity-TDS Meter Cl 280
 |
|
We provide a quality range of Water Treatment Meters, which is used for the measurement of conductivity of aqueous solutions. It is manufactured using quality material and is known for its reliability & high performance.
|
Chemiline Make Digital Photoelectric Colorimeter Cl 610 & Cl 620
Chemiline make digital photoelectric colorimeter cl 610 & cl 620 is an accurate instrument designed for use in various colorimetric analysis. It is easy to operate, accurate and robust. The salient features are ‘digital readout, simple operation, stray light immunity and robustness. Specifications:cl 610&cl 620 - Wavelength : 400 nm to 700 nm selected byl filters outed on a turret
- Light source : 6. 3 v, 0. 3 a lamp
- Detector : photo — cell
- Display : 2 % digit digital panel mleter(dpm)caiibrated directly in %transmission & optical density.
- Resolution : 1 % in transmission mode & 0. 01 in optical density mode
- Power supply : 230 x 10 % 50 hz
| 
 |
Chemiline Make Micro Controller Based Photoelectric Colorimeter Cl 660
Chemiline make micro controller based photoelectric colorimeter cl 660 is an accurate instrument designed for use in various colorimetric analysis. It is easy to operate, accurate and robust. The salient features are digital readout, simple operation, stray light immunity and robustness ,it has also facility of two point and end point chemistry. Specifications: cl 660 - Wavelength : 400 nm to 700 nm selected by filters mounted on a turret
- Light source : 6. 3 v, 6w
- Detector `photo — cell
- Mode 2 absorbency, concentration,chemistry
- Chemistry : two point, end point c
- Display ; 16*2 digit lcd
- Sccessory test tubes —-- 4 nos.
Black rod —-— 1 no. Instruction manual | 
 |
Chemiline Digit Conductivity Meter Cl 220
Chemiline digit conductivity meter cl 220 is designed to measure the specific conductivity of a solution using a conductivity cell. Lt enables to measure the conductivity directly on dpm. This instrument incorporates an integrated circuitry and thus the power consumption is very low. Specifications: cl 220 - Conductivity range : 0 to 200 m mho or m s
- Measuring accuracy : ;1 % of f. S. In all the ranges
- Display : 2 % digit digital panel meter.
- Conductivity cell : approx 1. 0 cell constant
- Cell constant : 0. 9 to 1. 1 compensation
- Power requirement : 230 volt + or - 10 %,50 hz
- Standard accessories : conductivity cell instruction manual. stand and clamp
- Temperature
| 
 |
Chemiline Digit Conductivity Meter Cl 250
CHEMILINE Digit Conductivity Meter CL 250 is designed to measure the specific conductivity of a solution using a conductivity cell. lt enables to measure the conductivity directly on DPM.This instrument incorporates an integrated circuitry and thus the power consumption is very low. Specifications: CL 250 - Conductivity Range : 0.1 u MHO or p S to 100 m MHO or m S
- Measuring Accuracy :1 % of f.s._j1 count
- Display : 20* 4 Digit LCD.
- Conductivity Cell : 0.1 c.c. & 1.0 c.c. `
- Cell Constant :Acceptable from 0.1 to 5.0
- Power Requirement :230 volt + or 10 %,50 l-lz
- Standard Accessories :Conductivity Cell Instruction Manual Stand and Clamp
- Temperature : - 0 to 100 ° C with PT 100 Sensor or Manual no
| 
 |
Chemiline Digital Conductivity-TDS Meter Cl 210
Chemiline digital conductivity-tds meter cl 210 is designed to measure the specific conductivity of a solution using a conductivity cell, and estimates tds (total dissolved solid) by multiplying the conductivity with a user specified tds-factor. ,the unit also measure the temperature using a pt 100 sensor lt enables to measure the conductivity directly on dpm the unit is equipped to provide conductivity at the existing temperature as it is ,or corresponding to a standard temperature of 25 °ci. E. With temperature compensation, automatically or manually, both. The manual mode allows temperature compensation with out the temperature sensor. The tem pco is user selectable. Specifications:- - Range cl 210
- Conductivity temco range : 2us to 200 ms with 0. 1 cell constant and 20;. 15 to 200 ms with unity l cell constant . In 5 decade range
- TDS ; 2 ppm to 2 ppt with 0. 1 celi constant and 20 ppm to 200 ppt f
- Temperature 1 0 "c to ‘l00°c
- Resolutlon
- Conttuctivty 0. 01 in lowest range with 0. 1 cell constant
- TDS 0. 01 ppm with 0. I cell constant
- Accuracy
- Conductivity tds 2 + 1 % ot rs. + 1 count
- Temperature : +1 "c.
- Cell compensation
- TDS factor : 0. 20 to 1. 00 i
- Conductivity 1 0 to 3. 0 % per c
- Temperature range
- Power requiement 230 volt + or 10 00. 50 hz
- Display 2 digit digital panel meter
| 
 |
Chemiline Digital Conductivity-TDS Meter Cl 280
Chemiline digital conductivity-tds meter cl 280 is designed to measure the specific conductivity of a solution using a conductivity cell, and estimates tds (total dissolved solid) by multiplying the conductivity with a user specified tds—factor. ,the unit also measure the temperature using a pt 100 sensor lt enables to measure the conductivity directly on dpivi the unit is equipped to provide conductivity at the existing temperature as it is ,or corresponding to a standard temperature of 25 °ci. E. With temperature compensation, automatically or manually, both. The manual mode allows temperature compensation with out the temperature sensor. The tem pco is user selectable. Specifications: - Range cl 280
- Conductivity temco range 1 0. 1ps to 100ms
- TDS ; 1 ppm to 200 ppt
- Temperature ` 0 °c to 99. 9°c
- Resolutlon
- Conductivity 0. 01 ps
- TDS 0. 01 ppm
- Accuracy
- Conductivity/tds ' i1 % of count
- Temperature : +1 "c.
- TDS factor ‘ o. 20 to 1. 00
- Conductivity : 0 to 3. 0 % per °c
- Tempco range
- Display :20*4 lcd
| 
 |
|