HIGH SPEED MASTER TRIP (2 ELEMENTS) AVAJH23 Standard Specifications :
Operating Limits : 50 to 120% of rated coil voltage. Operational Time : 10 - 15ms at nominal rated voltage. Coil Rating : 24V / 30V / 110V / 220V DC or AC. Burden : @30 VDC / 24VDC : 7 VA, @110 VDC : 10 VA, @220VDC : 7 VA. Opeational Indicator : Mechanical Flag (Red for Alarm, White for Normal) in window : HR Type. Contacts : 4 Pair of HR (Hand Reset). Combinations : 4NO, 3NO+1NC, 2NO+2NC, 1N0+3NC. Each. Relay conforms : 1S : 3231 - 1981 fully for requirements.
Your enquiry has been sent
Processing...
HIGH SPEED VOLTAGE OPERATED AVAJS13 Standard Specifications :
Operating Limits : 50 to 120% of rated coil voltage. Operational Time : 10 - 15ms at nominal rated voltage. Coil Rating : 24V / 30V / 110V / 220 VDC AC coils are also available. Burden : @30 VDC / 24VDC : 7 VA, @110 VDC : 10 VA, @220VDC : 7 VA. Operational Indicator : Mechanical Flag (Red for Alarm, White for Normal) in window : HR Type. Contacts : 4 Pairs of SR. Combinations : 5NO+1NC, 4NO + 2NC, 3NO + 2NC, 3NO + 1 NC, 2NO + 2 NC.. Relay conforms : IS : 3231 - 1981 fully for all requirements
Your enquiry has been sent
Processing...
High Speed Master Trip Electromechanical Relay : AVAJH13 Standard Specifications :
Operating Limits : 50 to 120% of rated coil voltage. Operational Time : 10 - 15ms at nominal rated voltage. Coil Rating : 24V / 30V / 110V / 220V DC or AC. Burden : @30 VDC / 24VDC : 7 VA, @110 VDC : 10 VA, @220VDC : 7 VA. Operational Indicator : Mechanical Flag (Red for Alarm, white for Normal) in window : HR Type. Contacts : 5 pair of HR (Hand Reset). Combinations : 5 contacts. Relay conforms : IS : 3231 -1981 fully for all requirements.
Your enquiry has been sent
Processing...
High Speed Master Trip Relay Standard Specifications :
Operating Limits : 50 to 120% of rated coil voltage. Operational Time : 10 - 15ms at nominal rated voltage. Coil Rating : 24V / 30V / 110V / 220V DC or AC. Burden : @30 VDC / 24VDC : 7 VA, @110 VDC : 10 VA, @220VDC : 7 VA. Operational Indicator : Mechanical Flag (Red for Alarm, White for Normal) in window : HR Type. Contacts : 4 Pair of HR (Hand Reset) Each. Combinations : 4NO, 3NO + 1 NC, 2NO + 2NC, 1NO + 3NC for A & B elements. Only 3 pairs of contacts on elements C in 3NO, 2NO + 1 NC, or 3NC combination. Relay Conforms : IS : 3232 - 1981 fully for requirements.
Your enquiry has been sent
Processing...
VOLTAGE OPERATED AUXILIARY (2 ELEMENTS) RELAY, Standard Specifications :
Operating Limits : 70 to 110% of rated coil voltage. Operational Time : 20 - 25 ms at nominal rated voltage. Coil Rating : 24V / 30V / 110V / 220 VDC. AC coils are also available. Burden : @30 VDC / 24 VDC : 3 VA, @110 VDC : 2 VA, @220 VDC : 4 VA. Operational Indicator : Mechanical Flag (Red for Alarm, White for Normal) in window : HR Type. Contacts : 2 NO SR and 1NO - 1 NC HR for each element. Other Combination is also available on request. Relay conforms : IS : 3231 - 1981 fully for all requirements.
Your enquiry has been sent
Processing...
VOLTAGE OPERATED AUXILIARY RELAY (2 ELEMENTS) Standard Specifications :
Operating Limits
:
70 to 110% of rated coil voltage.
Operational Time
:
20 - 25 ms at nominal rated voltage.
Coil Rating
:
24V / 30V / 110V / 220 VDC. AC coils are also available.
Burden
:
@30 VDC / 24 VDC : 3 VA, @110 VDC : 2 VA, @220 VDC : 4 VA.
Operational Indicator
:
Mechanical Flag (Red for Alarm, White for Normal) in window : HR Type.
Contacts
:
4 pair of SR.
Combinations
:
4NO, 3NO+1NC, 2NO+2NC, and 1NO+3NC. Each
Relay conforms
:
IS : 3231 - 1981 fully for all requirements.
Your enquiry has been sent
Processing...
VOLTAGE OPERATED AUXILIARY RELAY WITH HR CONTACTS : AVA33 Standard Specifications :
Operating Limits : 70 to 110% of rated coil voltage. Operational Time : 20 - 25 ms at nominal rated voltage. Coil Rating : 24V / 30V / 110V / 220V, DC/ AC. Burden : @30 VDC / 24 VDC : 3 VA, @110 VDC : 2 VA, @220 VDC : 4 VA. Operational Indicator : Mechanical Flag (Red for Alarm, White for Normal) in window : HR Type. Contacts : 4 pair of HR (hand Reset) Each. Combinations : 4NO, 3NO + 1NC, 2NO + 2NC, 1NO + 3NC, 4NC for A, B & C elements. Relay conforms : IS : 3232 - 1981 fully for all requirements.
Your enquiry has been sent
Processing...
VOLTAGE OPERATED AUXILIARY RELAY WITH SR CONTACTS : AVA11 Standard Specifications :
Operational Limits
:
70 to 110% of rated coil voltage.
Operational Time
:
20 - 25ms at nominal rated voltage.
Coil Rating
:
24V / 30V / 110V / 220V DC or AC.
Burden
:
@ 30 VDC / 24VDC : 3 VA, @110 VDC : 2 VA, @ 220VDC : 4 VA.
Operational Indicator
:
Mechanical Flag (Red for Alarm, White for Normal) in window : HR Type.
Contacts
:
4 Pair of SR. (Self Reset).
Combinations
:
4 NO, 3NO + 1NC, 2NO + 2NC, 1NO + 3NC. (Ref. : Drawing AXL00501 ).
Relay Conforms
:
IS : 3231 -1981 Fully for all requirements.
Your enquiry has been sent
Processing...
Voltage Operated Auxiliary Relay Voltage Operated Auxiliary Relay (3 Elements) With Sr Contacts :
Standard Specifications :
Operating Limits : 70 to 110% of rated coil voltage. Operational Time : 20 - 25 ms at nominal rated voltage. Coil Rating : 24V / 30V / 110V / 220V DC/AC. Burden : @30 VDC / 24 VDC : 3 VA, @110 VDC : 2 VA, @220 VDC : 4 VA. Operational Indicator : Mechanical Flag (Red for Alarm, White for Normal) in window : HR Type. Contacts : 4 Pair of SR (Self Reset) Each. Combinations : 4NO, 3NO + 1NC, 2 NO + 2 NC, 1NO + 3NC, 4NC for A, B & C elements. Relay conforms : IS : 3231 - 1981 fully for all requirements.
Your enquiry has been sent
Processing...
Voltage Operated Auxiliary Relay Voltage Operated Auxiliary Relay with SR Contracts
Features :
Contacts conforms to IS : 3231. Duty : 1250VA. Attracted armature type compact design with positive action. Din Standard size compact cabinet. SR contacts are available (with or without flags). Two independent coils in one cabinet. Application :
High speed tripping duties. Low burden sensitive relay. To multiply the contacts, for Protection Relay.
Operation :
There are two independent relay elements in same cabinet. The coil of each element is directly brought on
terminals 9, 10 (element A) & 29, 30 (element B). After applying the energizing voltage at these terminals, the relay
operates and NO contact closes and NC contact opens. The Contacts are available as Self Reset (SR) type only.
Relays are available with or without flags and AC or DC coil.