Overcurrent Protection

We deal in Over Current Protection


3 Over Current 1Earth Fault Numerical Relay

3 Over Current 1Earth Fault Numerical Relay
General Description :

The ADR241B is multifunction over current / Earth fault Numerical relay design for requirement of typical medium voltage feeder. All the relay are designed using latest numerical technology and having programmable digital input and outputs to minimized external contact multiplication electromechanical relays. All relays are tested for EMI / EMC noise as per international IEC specifications.
General features of all relays are as given below


Specifications :

·         4 Element (3 Phase + EF + Sensitive 
          EF) Over current IDMT/DMT with instant trip.

·         Selection of Curve: Five selectable curve
          (Normal Inverse 1 Normal Inverse 2, Very
          Inverse Extremely Inverse Long Time
          Inverse and Define Time.

·         2 Setting Groups.

·         4 stages of Phase Over Current element.
          (Ip1>, Ip2>, Ip>> and Ip>>>) (50,51).

·         3 stages of 3Io (Internally derived EF)
          (3Io>, 3Io>> and 3Io>>>) (50N,51N).

·         3 stages of Ie (Externally EF or REF) (Ie>,
          Ie>> and Ie>>>) (64).

·         Trip Circuit Supervision.(TC)

·         Breaker Failure Detection.(BF)

·         Monitoring Functions.

·         Auto Reclose Relay (ARR).(79)

·         Negative Phase Sequence.(46)

·         Relay / Led configuration.

·         Large 20x4 LCD display for Parameter and
          setting display.

·         Disturbance Recorder. Up 3 sec

·         Fully communicable with IEC standard open
          protocol. IEC60870-5-103 (RS232C and
          RS485)

·         6 Digital Output (DO) and 8 Optically 
          isolated digital status input (DI)

·         Programmable Logic of DI/DO.

·         100 nos of event memory, 10 nos of Fault
          data stored with keypad interface and time 
          stamping.


 
 

Current / Eearth Fault Protection Relay

Current / Eearth Fault Protection Relay
Numerical Communicable Over Current / Eearth Fault Protection Relay
General Description :

The Numerical Communicable OC/ EF Protection Relay is communicable 3 OC and 1 EF relay with Instantaneous high set and programmable output to simplify feeder protection wiring.

Specifications :

·         4 Element (3 Phase + EF) over current
          IDMT with instant trip.

·         Display of fault current. / Load current.

·         Selection of Curve: Six selectable curves
          (Normal Inverse1 (C1), Normal Inverse2
          (C2), Very Inverse (C3), Extremely Inverse 
          (C4), Long Time Inverse (C5) & Definite
          Time (C6).

·         Separate curve selection for phase and EF.

·         Latching of fault current up-to last 5 fault.

·         Site selectable CT secondary

·         Programmable Annunciation Contact

·         Trip circuit supervision function.

·         Breaker Fail.

·         SCADA compatibility. IEC60870-5-103
          protocol.

 


 
 

Differential Protection Relay

Differential Protection Relay

ADR233A is second generation Numerical 3 Phase Tx Transformer differential Protection Relay. It consist all the necessary protection and monitoring functions required for transformer, it consist of

 

  • High Speed Digital DSP Controller
  • Analog Measuring Module
  • Power supply Module
  • Digital Input output module.

 

 The High speed Digital Signal Controller continuously monitors line HV and LV current + REF current. Along with different status input, through CTs, and optical isolated status connections. The high-speed micro-controller samples these current signals through a A/D converter. The Digital Signal performs powerful Numerical Algorithms to find out RMS of fundamental & harmonic contents of the current. All measurement is tuned to fundamental frequency i.e 50Hz, thus relay remain stable during distorted waveform generated electronics loco-motive. All these measure values are then used for different protection function.. These measured values are also displayed on large 20 x 4 LCD display for metering purpose. The DSC also monitor different digital input through optical isolator and control potential free contact for control CB and generate ALARM and Telesignalling.

 

Main Functions

 The ADR233A are having following protection functions.

 

  • Transformer differential protection.
  • REF protection.
  • Breaker Failure Detection.
  • Monitoring Functions.

 

 Each of these functions are independently programmable and can be enable or disable by user depending upon requirement.

 

Protection Features:

 

  • 3Phase Tx. Differential Protection + REF
  • Programmable (Non- Volatile) Setting By local keys as well as remote setting by communication port
  • Latching of fault current value.
  • Operation base on fundamental frequency value.
  • Harmonics restrain for Tx charging and CT saturation condition.
  • Breaker Failure detection.
  • Cross harmonics restrain.
  • Programmable starting current.
  • Programmable Internal ICT( interposing CT) ratio to match different transformer having different vector groups
  • Programmable dual bias setting.

 

For More Details Download PDF


Product Code: ADR233BV2

 
 

Directional IDMT Relay

Directional IDMT Relay

The ADR145A is member of Ashida Numerical Relay family (Aditya Series) design to meet  demand of low and medium switchgear control. The ADR145A is a Directional 3 OC and 1 EF IDMT relay with Instantaneous high set and programmable output to simplify feeder protection wiring. The ADR145A continuously monitors all 3 phase and earth current, through CT connections. The high-speed micro-controller samples this current through a 12-bit A/D converter. The micro-controller performs powerful Digital Algorithms to find out Amplitude of current signal, direction of power flow then this value is use for protection and metering function. All measurement is tuned to fundamental frequency. Each input current is also displayed on 16 x 2 LCD display for metering.

The Relay is having main three functions 

 

  • Protection
  • Self-Supervision 
  • Measurement.


Features:

 

  • 4 Element (3 Phase + EF) Over current IDMT with instant trip.
  • Programmable (Non- Volatile) Setting By local keys as well as remote setting by communication port.
  • Back - lit LCD display for settings.
  • Display of fault current. / Load current.
  • Selection of Curve: Five selectable curves, Normal Inverse1 (C1), Normal Inverse2, (C2) Very inverse (C3), Extremely inverse (C4), Long time inverse (C5).
  • Design using DSP technology
  • Latching of fault current.
  • Direction OC/EF Characteristic.
  • Programmable MTA +30, +45and +60 for phase and – 14, -30, -45 for EF.
  • Pass-word protection for setting.

 

For More Details Download PDF


Product Code: ADR145A

 
 

Earth Fault Medium Voltage Protection Relay

Earth Fault Medium Voltage Protection Relay
Numerical 3 Over Current 1Earth Fault Medium Voltage Protection Relay
General Description :

The ADR141C is a 3 OC and 1 EF Medium Voltage Protection relay with Instantaneous high set and programmable output design in very compact cabinet.

ANSI

Protection Functions

50

Instantaneous Over current Protection (OC-Inst.)

50N

Instantaneous Earth Fault Protection (EF-Inst.)

51

Time Over current Protection (Phase) (OC-IDMT.)

51N

Time Over current Protection (Earth) (EF-IDMT.)



Specifications :

·         4 Element (3 Phase + EF) over
          current IDMT with instant trip.

·         Display of fault current. / Load current.

·         Selection of Curve: Six selectable curves
          (Normal Inverse1 (C1), Normal Inverse2
          (C2), Very Inverse (C3), Extremely Inverse
          (C4), Long Time Inverse (C5) & Definite
          Time (C6).

·         Separate curve selection for phase and EF.

·         Latching of fault current up-to last 5 fault.

·         Site selectable CT secondary

·         Programmable Annunciation Contact

·         Trip circuit supervision.


 
 

Earth Fault Switchgear Protection Relay

Earth Fault Switchgear Protection Relay
General Description :

The ADR141A is a  Numerical 3 OC and 1 EF Switchgear Protection relay with Instantaneous high set and programmable output to simplify feeder protection wiring.

ANSI

IEC

Protection Functions

50

I >>

Instantaneous Over current Protection (OC-Inst.)

50N

IE>>

Instantaneous Earth Fault Protection (EF-Inst.)

51

I>t, Ip

Time Over current Protection (Phase) (OC-IDMT.)

51N

IE>t, IEP

Time Over current Protection (Earth) (EF-IDMT.)


Specifications :

·         4 Element (3 Phase + EF) over current 
          IDMT with instant trip.

·         Display of fault current. / Load current.

·         Selection of Curve: Six selectable curves
          (Normal Inverse1 (C1), Normal Inverse2
          (C2), Very Inverse (C3), Extremely Inverse
          (C4), Long Time Inverse (C5) & Definite
          Time (C6).

·         Separate curve selection for phase and EF.

·         Latching of fault current up-to last 5 fault.

·         Site selectable CT secondary

·         Programmable Annunciation Contact

·         Trip circuit supervision function.

·         Breaker Fail.


 
 

Numerical 3 Over Current Plus 1 Earth Fault Protection Relay

Numerical 3 Over Current Plus 1 Earth Fault Protection Relay

Numerical 3 OC Plus 1 EF Protection Relay ADR241B V2 Series is second generation Numerical 3 OC + 1EF Over Current Relay. It consist all the necessary protection and monitoring functions required for Normal feeder it consist of

 

  • High Speed Digital DSP Controller
  • Analog Measuring Module
  • Power supply Module
  • Digital Input output module.

 

The High speed Digital Signal Controlle continuously monitors line phase current and E/F current. Along with different status input, through CTs, and optical isolated status connections. The high-speed micro-controller samples these current signals through a A/D converter. The Digital Signal performs powerful Numerical Algorithms to find out RMS of fundamental & harmonic contents of the current. All measurement is tuned to fundamental frequency i.e 50Hz, thus relay remain stable during distorted waveform generated electronics loco-motive. All these measure values are then used for different protection function such as IDMT Over current protection, Instantaneous Over current protection, E/F protection etc.

The relay is having total 8 nos of dual LED of high intensity for easy identification of type of fault for easy user interface. LEDs L5, L6 and L7 and Relay R1 to R5, digital status input and controlled output are fully programmable via key pad interface.

Main Function

The ADR241B are having following protection functions.

 

  • 3 stage phase over current element. (Ip>,Ip>> and Ip>>>).
  • 3 stages of 3Io (internally derived EF) (3Io>, 3Io>> and 3Io>>>).
  • 3 stages of Ie (externally EF or REF) (Ie>, Ie>> and Ie>>>).
  • Trip Circuit Super vision.


Protection Features:

 

  • 4 Element (3 Phase + EF + sensitive EF) Over current IDMT/DMT with instant trip.
  • Programmable (Non- Volatile) Setting By local keys as well as remote setting by communication port
  • Selection of Curve: Five selectable curve (Normal Inverse1 (C1), Normal Inverse2, (C2) Very inverse (C3), Extremely inverse (C4), Long time inverse (C5)) and Define Time (C6)
  • Instantaneous Over-Current Protection with adjustable timer.
  • Breaker Failure detection.
  • In-built CB Trip Circuit Supervision function during pre closing and post closing of CB.
  • Negative sequence over current (46).
  • Breaker TRIP/CLOSE operation directly from relay keypad

 

For More Details Download PDF

Product Code: ADR241BV2

 
 

Numerical Directional 3 Over Current 1Earth Fault Feeder Protection Relay

Numerical Directional 3 Over Current 1Earth Fault Feeder Protection Relay
General Description :

The ADR245B is multifunction complete feeder protection relay (directional over current / Earth fault) relay design for requirement of typical medium voltage feeder. All the relay are designed using latest numerical technology and having programmable digital input and outputs to minimized external contact multiplication electromechanical relays. All relays are tested for EMI / EMC noise as per international IEC specifications.
General features of all relays are as given below

Specifications :

 ·         4 Element (3 Phase + EF + Sensitive EF)
           Directional Over current IDMT/DMT with
           instant trip.

·         Selection of Curve: Five selectable curve
          (Normal Inverse 1 Normal Inverse 2, Very
          Inverse Extremely Inverse Long Time
          Inverse and Define Time.

·         2 Setting Groups.

·         4 stages of Phase Directional / Non
          Directional Over Current element. (Ip1>,
          Ip2>, Ip>> and Ip>>>). (50,51,67).

·         100 nos of event memory, 10 nos of Fault
          data stored with keypad interface and time
          stamping.

·         3 stages of Directional / Non Directional 3Io
          (Internally derived EF) (3Io>, 3Io>> and 
          3Io>>>).(50N,51N,67N).

·         3 stages of Directional / Non Directional Ie
          (Externally EF or REF) (Ie>, Ie>> and
          Ie>>>).(64,67N).

·         Under Voltage (27)

·         Over Voltage (59)

·         Neutral Voltage Displacement (59N).

·         Trip Circuit Supervision.(TC).

·         Breaker Failure Detection.(BF).

·         Monitoring Functions.

·         Auto Recloser Relay (ARR).(79)

·         Negative Phase Sequence.(46).

·         Relay / Led configuration.

·         Large 20x4 LCD display for Parameter and
          setting display.

·         Disturbance Recorder. Up 3 sec.

·         Fully communicable with IEC standard open
          protocol. IEC60870-5-103 (RS232C and
          RS485).


 
 

Over Current / Earth Fault Protection Relay

Over Current / Earth Fault Protection Relay

General Description :


The Numerical Communicable OC/ EF Protection Relay ADR231A is a three element communicable numerical relay can having following option , 2 OC +1 EF or 3EF relay with Instantaneous high set and programmable output to simplify feeder protection wiring.

ANSI

Protection Functions

50

Instantaneous Over current Protection (OC-Inst.)

50N

Instantaneous Earth Fault Protection (EF-Inst.)

51

Time Over current Protection (Phase) (OC-IDMT.)

51N

Time Over current Protection (Earth) (EF-IDMT.)


·         3 Element (2 Phase + EF / 3 Phase / 3EF ) over current IDMT with instant trip.

·         Display of fault current. / Load current.

·         Selection of Curve: Six selectable curves (Normal Inverse1 (C1), Normal Inverse2 (C2), Very Inverse (C3), Extremely Inverse (C4), Long Time Inverse (C5) & Definite Time (C6).

·         Separate curve selection for phase and EF.

·         Latching of fault current up-to last 5 fault.

·         Site selectable CT secondary

·         Programmable Annunciation Contact

·         Trip circuit supervision function.

·         Breaker Fail.

·         RS232C and RS485 Communication port.


 
 

Over Current/Earth Fault Protection Relay

Over Current/Earth Fault Protection Relay
Numerical Communicable Over Current/Earth Fault Protection Relay :  ADR131A
General Description :

The ADR131A is a three element numerical relay can having following option , 2 OC +1 EF or 3EF relay with Instantaneous high set and programmable output to simplify feeder protection wiring.

ANSI

Protection Functions

50

Instantaneous Over current Protection (OC-Inst.)

50N

Instantaneous Earth Fault Protection (EF-Inst.)

51

Time Over current Protection (Phase) (OC-IDMT.)

51N

Time Over current Protection (Earth) (EF-IDMT.)



Specifications :

·         3 Element (2 Phase + EF / 3 Phase / 3EF )
          over current IDMT with instant trip.

·         Display of fault current. / Load current.

·         Selection of Curve: Six selectable curves
          (Normal Inverse1 (C1), Normal Inverse2
          (C2), Very Inverse (C3), Extremely Inverse
          (C4), Long Time Inverse (C5) & Definite
          Time (C6).

·         Separate curve selection for phase and EF.

·         Latching of fault current up-to last 5 fault.

·         Site selectable CT secondary

·         Programmable Annunciation Contact

·         Trip circuit supervision function.

·         Breaker Fail.


 
 

 

Related Product Catalogs

Coral Enterprises, Chennai
Supplier of capacitive switch, high tensile switch, touch electrical switches, high tensile switches, insulated switches, non metallic object detecting switch, control switches and temperature resistant switches.

View more details

Gaurav Engineers, Pune
Manufacturing and supplying of relay time switches, LED time switches, voltage time switches, micro controller time switches, industrial time switches, display time switches and digital time switches.

View more details

Girish Surgical Works
Supplying and manufacturing foot switches which includes metal foot switches, rubber foot switches, surgical foot switches, aluminum fabricated foot switches, single paddle foot switches and double paddle foot switches.

View more details

Suggested Companies


Related Categories
Search Suppliers
CompanyProductsTrade Leads
OR


IndiaMARTCompaniesProductsTrade LeadsTendersTrade ShowsTravel
© 1996-2012 IndiaMART InterMESH Limited. All rights reserved worldwide.