![]() | Ashida Electronics Private LimitedThane, Maharashtra | Year of Establishment: 1970 |
PRODUCTS & SERVICES |
ASCADA-SAS System (1)Autoreclose And Check Synchronisation (3)Auxiliaries, Trip Relays And Timers (9)
Circuit Breaker Failure (1)Overcurrent Protection (10)
Protection Relay (3)Transformer Protection And Restricted Earth Fault Protection (10)
Voltage, Frequency & Capacitor Monitoring (6) | Transformer Protection and Restricted Earth Fault ProtectionADR233B![]()
ASHIDA Numerical 3 Phase Tx. Differential + Over Current Protection Relay
EF Protection Relay![]() The ADR211E is member of Ashida Numerical Relay family (Aditya Series) design to meet demandof low and medium switchgear control. The ADR211E is single pole EF relay with instantaneous highset and programmable output to simplify feeder protection wiring. The ADR211E continuouslymonitors earth current, through CT connections. The high-speed micro-controller samples thiscurrent through a 12-bit A/D converter. The micro-controller performs powerful Digital Algorithmsto find out Amplitude of current signal, and then this value is use for protection and meteringfunction. All measurement is tuned to fundamental frequency. Each input current is also displayedon 16 x 2 LCD display for metering. Our range of relay is having following functions:
Following are the features of our range of numerical neutral displacement protection relay:
For More Details Download PDF
High Speed Master Trip Relay![]() We manufacture a wide range of speed master trip relay with HR contracts and auxiliary relay that operates in response to the opening or closing of its operating circuit to assist another relay or device in performing a function. These are fabricated using state-of-the-art technology and latest machinery. Our range of auxiliary relay is in great demand because of following features:
In addition, we provide customization on our range of auxiliary relay as per the specifications of our clients. For More Details Download PDF
Instantaneous Single Pole Restricted Earth Fault Relay![]() Instantaneous Single Pole Restricted Earth Fault Relay : ACAG14 General Description : The ACAG14 is a single element EF relay designed as restricted Earth fault protection to transformer winding. This can be available with or with or without timer.
Specifications : · Design using DSP technology. · Tuned to fundamental frequency. · Suitable For REF Protection. Numerical 3 Pole Differential Relay : ADR133A![]() General Description : ADR133A is a numerical transformer differential relay with dual bias characteristic for two winding transformer.
Specifications : · Online display of Phase Current / Differential Current. · Latching of fault current value. · High Speed operation. · Operation is based on fundamental frequency value. · Harmonics restrain for Transformer charging and CT saturation condition. · Programmable Internal ICT (Interposing CT) ratio to match different transformers having different vector groups. · Programmable dual bias setting. Numerical 3 Pole Differential Transformer Protection Relay![]() Numerical 3 Pole Differential Transformer Protection Relay : ADR233A General Description : ADR233A is a numerical differential transformer protection relay with dual bias characteristic for two winding transformer.
Specifications : · Online display of Phase Current / Differential Current. · Latching of fault current value. · High Speed operation. · Operation is based on fundamental frequency value. · Harmonics restrain for Transformer charging and CT saturation condition. · Programmable Internal ICT (Interposing CT) ratio to match different transformers having different vector groups. · Programmable dual bias setting. · SCADA compatibility. IEC60870-5-103 protocol. · Latching of Last 5 fault along with date and time stamp. · 25 Cycle of disturbance record and 100 Event memory. Numerical OC/EF Protection Relay![]() We offer a wide range of numerical non-directional IDMT protection relay. These are DSP based numerical, communicable, non communicable, non directional OC/EF relays. These are available with following protection functions:
Our range of numerical non- directional IDMT protection relay is manufactured adhering to IEC Standard standards. In addition our range is designed in IDMTCurves and its models are designed with site selectable CT Secondary [1Amp. / 5Amp] Standard Specifications: O/C setting:
E/F setting:
O/C HF setting:
E/F HF setting:
TMS setting:
Specifications required while ordering: IDMT curve:
For More Details Download PDF
Numerical UV/OV Protection Relay![]() We manufacture a wide range of numerical under/over voltage protection relay that are available with a number of protection functions like LBB, Trip Circuit Supervision and DI/DO. These are DSP based numerical, communicable, non communicable non-directional OC/EF Relays. Relay models are designed with IDMT curves and site selectable CT Secondary [1Amp. / 5Amp]. In addition, these are manufactured at international standards such as IEC. Standard Specifications: O/C setting:
E/F setting:
O/C HF setting:
E/F HF setting:
TMS setting:
Specifications required while ordering IDMT curve:
For More Details Download PDF
Protection Relay For RMU![]() Our clients can avail from us a wide range of numerical self powered IDMT protection relay that provide pulse output for low energy tripping coil of RMU. These relay are compatible and the entire RMU function can be remotely monitored. These are DSP based numerical, communicable, non-communicable and Non-Directional OC/EF relays. Standard Specifications: O/C setting:
E/F setting:
O/C HF setting:
E/F HF setting:
TMS setting:
Specifications required while ordering IDMT curve:
Related CT secondary:
For More Details Download PDF
Trip Circuit Supervisory Relay![]() We offer a wide range of Trip CIRCUIT Supervisory Relay that is manufactured using latest technology is of a standard modular construction of the draw out style. Trip Circuit Supervisory Relay is mainly used to supervise the trip circuit of a Circuit Breaker. In addition, TCSR detects bad contact, contact welding and trip circuits and other essential control cir- auxiliary voltage failures in the supervised circuits. The supervisory elements are continuously energized through these circuits, thus, their failure will be detected and alarmed. Features
For More Details Download PDF
|
| ||||||||||||||