AurolabAurolab
Foldable Intraocular Lens - Hydrophobic Foldable Intraocular Lens - HydrophilicPMMA Intraocular Lens Square Edge PMMA Intraocular Lens
Yellow PMMA Intraocular Lens Cataract ProductsCataract KitPharmaceutical Drugs & Retinal Products
Ophthalmic SuturesHand Surgical & Cardiovascular SuturesBipolar CoagulatorCapsular Tension Ring

Ophthalmic Products
Aurolab, started in 1992 provides a wide variety of ophthalmic consumable products. With a vision to assist in eradicating needless blindness worldwide, Aurolab is strictly focused in developing technologies from the western markets to make it available in developing markets worldwide. With the following divisions of Aurolab, Aurolab today is positioned for growth in these areas and in exploring new product requirements in Ophthalmology.


Foldable Intraocular Lens - Hydrophobic
Foldable Intraocular Lens - Hydrophobic

Aurolab introduces AuroVue, the first indigenously developed hydrophobic foldable lenses.

Highlights
  • Made of high purity acrylic material making it more biostable.
  • Has superior optical characteristics, flexibility and tensile strength.
  • Has force-enduring haptics that withstands pressure and keeps the lens intact.
  • Significantly, the tackiness of the material attaches itself to the posterior capsule and results in very minimal cell adhesion and PCO.
  • 360° square edge for preventing cell proliferation.
Every pack of Aurovue comes with a disposable injector and a locking cartridge.

Details

UV Absorbing Acrylic, Equiconvex Optic,
'A' Constant: 118.4 ACD:5.0mm

Diopter Range (all models): 10 to 15 in 1.0 D, 15 to 25 in 0.5D & 25 to 30 in 1.0D.

Model no
Optic Diameter(mm)
Overall Diameter(mm)
HP757SQ
5.75
12.5





Foldable Intraocular Lens - Hydrophilic

Aurolab foldable lenses are made out of proven, biocompatible, Poly – HEMA material imported from the USA. This material has remained safe since 1998 in patients’ eyes. Aurolab has introduced foldable lenses in 3 models viz., Aurofold, Auroflex and Microfold. These lenses have displayed consistently good post operative results.

Aurofold & Auroflex: 2.4 - 2.8mm incision*
Microfold: 1.4 - 1.8mm incision*

*The incision size will depend on the length of the cartridge tip introduced into the wound.

Details

UV absorbing poly HEMA (Hydroxy Ethyl Methacrylate), Equiconvex optic,
'A' Constant: 118.0 ACD: 5.0 mm
Diopter Range (all models): 10 to 15 in 1.0 D, 15 to 25 in 0.5 D& 25 to 30 in 1.0 D.

Model
Optic Diameter (mm)
Optic Diameter (mm)


Aurofold
FH3575
5.75
12.25
FH3600
6
12.25


Auroflex
FH5575
5.75
12
FH5600
6
12
FH5600SQ*
6
12


Microfold
FH1575
5.75
11
Each lens comes with a disposable injector and cartridge.

Foldable Intraocular Lens - Hydrophilic


PMMA Intraocular Lens
PMMA Intraocular Lens

Scleral Fixation Lens

Equiconvex optic, Modified 'C' Loop,
'A' Constant: 118.5, ACD:5.0 mm, 2 holes in haptics at 180 degree
Diopters Range: from 15.0 to 25.0 in 1.0 D

Model no
Optic Diameter(mm)
Overall Diameter(mm)
SC6530
6.5
13.0

Low Power Lens
Planoconvex Optic, Modified 'C' Loop,
'A'Constant: 116.8, ACD:4.2 mm
Diopter Range: From 4.0 to 7.0 in 1.0 D

Model no
Optic Diameter(mm)
Overall Diameter(mm)
S3P652
6.5
13.50
S3P550L
5.5
12.5
S3P602
6
12.5

Meniscus Optic, Modified 'C' Loop,
'A'Constant: 117.5

Diopter Range: From 0 to 3.0 in 1.0 D

Model no
Optic Diameter(mm)
Overall Diameter(mm)
SM3600
6
12.5
SM3600L
6
13




Square Edge PMMA Intraocular Lens

360°square edge single piece PMMA intraocular lens.

Advantages
  • 360°square edge for preventing cell proliferation.
  • Projected posterior edge for True 360°capsular contact.
  • Rounded anterior edge for reduced glare and glistening.
Truedge IOL is developed with the aim of making the benefits of square edge design available to the less privileged sections of society where PMMA lenses are still predominantly used. Its use reduces the incidence of PCO and hence is the best choice for an affordable solution to the problem.

Details

UV absorbing PMMA, equiconvex optic, Modified 'C' Loop,
'A' Constant: 118.5, ACD:5.0 mm
Diopter Range (all models): 10 to 15 in 1.0 D, 15 to 25 in 0.5 D& 25 to 30 in 1.0 D.
Model
Optic Diameter (mm)
Over all Diameter (mm)
S3550SQ
5.5
12
S3602SQ
6
12.5

AUROPED,

The 360° posterior square edge introcular lens is specially designed for the pediatric patients.

A variant of TruEdge, Auroped, specially designed for pediatric cases has also been introduced.

Details:

UV Absorbing PMMA Equiconvex Optic, Modifed "C" Loop,
'A'constant:118.5, ACD:5.0mm
Diopter Range: 18.0 to 25.0 in 0.5D.

Model
Optic Diameter (mm)
Over all Diameter (mm)
S3550PSQ
5.5
10.25



Square Edge PMMA Intraocular Lens


Yellow PMMA Intraocular Lens
Yellow PMMA Intraocular Lens

The blue light of the visible spectrum is said to have a harmful effect on the retina, especially the macular region. The soon to be introduced, Aurolab yellow tinted PMMA lenses, made from imported raw material, have an effective blue light filter that protects the retina.

It also has a 360°square edge on the posterior side that reduces PCO effectively.

UV and blue light absorbing Yellow PMMA, Equiconvex Optic, Modified "C" Loop,
'A'Constant: 118.5,ACD:5.0mm
Diopter Range: 10 to 15 in 1.0 D, 15 to 25 in 0.5 D& 25 to 30 in 1.0 D.
Model
Optic Diameter (mm)
Over all Diameter (mm)
S3602SQY*
6
12.5





Cataract Products

We offer an array of qualitative cataract and retinal products that efficiently support the eye sight and provide clear vision to the human eyes. These products are available in various composition and different product name, some of these include:

1.
Hypromellose Ophthalmic Solution USP 2% w/v -2 ml PFS (in pre-filled syringe)
AUROVISC


2ml
2.


Hypromellose Ophthalmic Solution USP 2% w/v


AUROVISC
3ml
3.
Hypromellose Ophthalmic Solution USP 2% w/v
AUROVISC
5ml


4.
Trypan Blue Solution 0.06% w/v (Staining of Anterior Capsule)
AUROBLUE
1ml (5 vials/box)
5.
Pilocarpine Nitrate Ophthalmic Solution 0.5% w/v
AUROCARPINE
1ml(5 vials/box)
6.
Sodium Hyaluronate Ophthalmic solution 1.4% w/v (in pre-filled syringe)


AUROGEL
1ml


Cataract Products


Cataract Kit
Cataract Kit

Cataract kit, a pioneering concept, was evolved in response to the requirement from certain developing countries where availability and procurement of surgical consumables was a daunting task. This customized pack of preoperative, intraoperative and postoperative ophthalmic consumables, required for 5 cataract surgeries (SICS and PHACO), was largely welcomed in the developing countries as it paved way for increased efficiency of prevention of blindness camps and programs. This pack is designed to provide all the necessary ophthalmic consumables at one stop, keeping in view absolute customer convenience.

Highlights
  • Convenience of procuring cataract consumables from a single point source.
  • Customized assembly of procedure-specific consumables to help the surgeon perform more efficiently.
  • Wide variety of choice available for different cataract procedures.
  • The surgical team needs less time to prepare for each surgery.
  • Reduced wastage and spillover of consumables.
  • Efficient cost and inventory management.
  • Intraocular lenses, suture needles, Trypan Blue and HPMC are CE certified.



Pharmaceutical Drugs & Retinal Products

We also offer a wide range of pharmaceutical drugs and retinal products which are quite effective in treatment of eye related problems. This range includes:

Pharmaceutical drugs

Alkaliburns
Anti-allergic
Anti-inflammatory-NSAID
Artificial tears
Antibiotics with steroid
Astringent
Antifungal
Agents for glaucoma
Local anesthetics

Retinal Products

1.
Indocyanine Green for Inj USP (Retinal Angiography)


AUROGREEN
(Lyophilized)


25mg
2.
Perfluoro-n-octane Liquid
AURO OCTANE
5ml
3.
Silicone Oil 1000 mm 2/s (cSt)
AUROSIL
10ml
4.
Triamcinolone Acetonide Injection IP 40mg
AUROCORT
1ml(5 vials/box)
5.


Trypan Blue 0.15% w/v
RETIBLUE
1ml(5 vials/box)




Pharmaceutical Drugs & Retinal Products


Ophthalmic Sutures
Ophthalmic Sutures

We offer non absorbable ophthalmic sutures that are widely used in surgical works by eye care specialists. Fabricated from highly qualitative raw material these sutures are hygienic and absolutely safe for the surgical purpose. The various sizes of these sutures available with us are:

Material
Sizes available
Single Arm / double Arm
Aurolon - Nylon Black Monofilament
10-0`
9-0`
8-0`


SA / DA
SA / DA
SA / DA
Aurosilk - Black Braided Silicone coated / Virgin Silk
8-0`
6-0`
4-0`
SA / DA
SA/DA
SA
Aurobond - Polyester Green Braided
5-0`
4-0`
2-0`
SA
SA
DA
Aurolene - Polypropylene Blue Monofilament
10-0` 






9-0`




5-0`
Available in Double straight needles & one straight and one curved needle
Available in Double straight needles & one straight and one curved needle

SA




Hand Surgical & Cardiovascular Sutures

We offer hand surgical and cardiovacular sutures used in surgical works. Our sutures are made from good quality raw materials are hygienic and safe for the surgery. These sutures are available in following range of sizes:

Hand Surgical Sutures:


Material
Sizes available
Single Arm / double Arm
Aurolon - Nylon Black Monofilament
11-0’
10-0`
9-0`
8-0`


SA
Aurolene - Blue Monofilament Polypropylene


10-0`
9-0`
8-0`
SA

Cardiovascular Sutures:

Material
Sizes available
Single Arm / double Arm
Blue Monofilament Polypropylene
1-0’
4-0`
5-0`
6-0`
7-0’
8-0’
SA
DA & SA
DA
DA
DA
DA
Black Monofilament Nylon


5-0’
4-0’
3-0’
2-0`
SA
SA
SA
SA




Hand Surgical & Cardiovascular Sutures


Bipolar Coagulator
Bipolar Coagulator

Wet Field Bipolar Coagulator (Solid State)

Aurolab manufactures Aurocautery, which is a wet field bipolar coagulator. Mainly used in ophthalmic surgeries. It offers precise hemostasis of blood vessles like epiceleral, intrasceleral and intraocular hmostasis and provides precise tissue coaptation like conjunctiva closure. Tissue may be coagulated under irrigation (wet- field) with saline or under bloody field.

Specification:

• Model : ACD-01
• Supply Voltage : 110 V ac, (on request)
• Radio frequency : 455 KHz
• Output RF Power : 7W approx
• Dimension : 140(W) X 50(H) X 170(B) mm
• Weight : 1.5 Kg approx
• Casing : Powder coated M.S body.

FEATURES:

• High frequency solid state circuitry.
• Compact in size, elegant look and easy to use.
• Reusable forceps, erasers and cables
• Foot switch control
• Audible indication
• Dial for variable power output
• Supplied with test certificate and Instructions for use leaflet



Capsular Tension Ring

We offer accurately designed capsular tension rings that are fabricated from qualitative raw material making it quite hygienic. The available model with us is Auro Ring in various categories as follows:

Auro Ring - Capsular Tension Ring
These Capsular Tension Ring are used to stabilize and recentre the capsular bag in cases of damaged or missing zonules, lens subluxation, pseudoexfoliation, myoplia zonulolysis, soft IOL.
  • Promotes circular expansion of the capsular bags.
  • Stabilizes conditions during surgery.
  • Improves IOL centration.
  • Resists capsular shrinkage.
Auro Ring – Modified Capsular Tension Rings With Single And Double Loop
These rings, specially designed for scleral fixation with suture, are also manufactured at Aurolab. These rings are extremely helpful in cases of progressive zonulysis and large zonular dialysis.

Auro Ring - Capsular Tension Segment
The Capsular Tension Segment is a partial ring with a fixation hook for temporary or permanent fixation. It can be placed following anterior capsulotomy and fixated using an iris retractor. For permanent fixation, it can be sutured in place.
  • One or more, as necessary, can be used to support parts of the capsule that have insufficient zonular support.
  • Placement is easy and atraumatic, even before phaco.
  • No sharp points to tear the capsulorhexis.
  • Can be used even when anterior or posterior capsular tears are present.

Capsular Tension Ring




Copyright © Aurolab, All Rights Reserved (Terms of Use)
Developed by IndiaMART InterMESH Limited