| S. No. |
Description |
BO - 25 |
BO -
50 |
BO-100 |
| 1 |
Capacity (acetylene with purity as per IS-30B) Cubic Meter per
hour |
25 |
50 |
100 |
| 2 |
Process water required (liters/kg of calcium
carbide processed) |
10-Aug |
10-Aug |
10-Aug |
| 3 |
Calcium carbide required
(kg/N.cubic meter of gas) |
4 |
4 |
4 |
| 4 |
Calcium chloride required
(gms/N.cubic meter of gas) |
50 |
50 |
50 |
| 5 |
Cooling water make-up
required (liters/N.cubic meter of gas) |
10 |
10 |
10 |
| 6 |
Power required
(average requirement) |
12KW |
15KW |
28KW |
| 7 |
Purifying mass required
(gas plus acid absorption mix per cum ofgas) |
15 gms/N.Cum + 4 gms |
15 gms/N.Cum + 4 gms |
15
gms/N.Cum + 4 gms |
| 8 |
Instrument/Process
air |
70 |
70 |
70 |
| liters/minute |
liters/minute |
liters/minute |
| 9 |
Acetone |
As required |
As required |
As
required |
| 10 |
Hydraulic oil required (for screw feed system) |
Equivalent to SAE -
30 |
Equivalent to SAE - 30 |
Equivalent to SAE - 30 |
| 11 |
Lubricating oil
required (for compressor) |
Hylube HDX-40 |
Hylube HDX-40 |
Hylube
HDX-40 |
| 12 |
Power Supply |
440 Volts/3 phase/50 hertz |
440 Volts/3 phase/50
hertz |
440 Volts/3 phase/50 hertz |