Indiamart
Biomax Corporation
Chandigarh

Electrophoresis And Western Blotting

The Electrophoresis and western blot (sometimes called the protein immunoblot) is a widely used analytical technique used to detect specific proteins in the given sample of tissue homogenate or extract. It uses gel electrophoresis to separate native proteins by 3-D structure or denatured proteins by the length of the polypeptide. The proteins are then transferred to a membrane (typically nitrocellulose or PVDF), where they are probed (detected) using antibodies specific to the target protein.

Horizontal Electrophoresis System

Horizontal Electrophoresis System

Various submerged horizontal electrophoresis cells are offered. All cells include components for casting gels. Horizontal Electrophoresis System is ideal for high-throughout laboratories. These Horizontal Electrophoresis System are known for their performance and quality and is widely appreciated by our clients. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.


SDS- PAGE Electrophoresis System

SDS- PAGE Electrophoresis System

Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) is a technique for separating proteins based on their ability to move within an electrical current, which is a function of the length of their polypeptide chains or of their molecular weight. This is achieved by adding SDS detergent to remove secondary and tertiary protein structures and to maintain the proteins as polypeptide chains. The SDS coats the proteins, mostly proportional to their molecular weight, and confers the same negative electrical charge across all proteins in the sample. Glycosylated proteins may not migrate at their expected molecular weight since their migration is based more on the mass of their polypeptide chains, not the sugars that are attached. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.

Power Supply

Power Supply

A power supply is a device that supplies electrical energy to one or more electric loads. The term is most commonly applied to devices that convert one form of electrical energy to another, though it may also refer to devices that convert another form of energy to regulated power supply is one that controls the output voltage or current to a specific value, the controlled value is held nearly constant despite variations in either load current or the voltage supplied by the power supply's energy source. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.

Gel Dryer

Gel Dryer

Geldryers, highly appreciated for their durability, very quiet operation and reliability, are for drying vertical slab gels and provide optimal drying for all types of gels. The dryers Minidry, Mididry and Maxidry feature temperature regulation between ambient temperature +5°C and 90°C.

The gels are heated from below and the vacuum removes the moisture from below to dry the gel homogeneously. When applying the vacuum by a membrane vacuum pump a groove that frames the drying surface provides an optimum tight seal during the drying period. All gel dryers are equipped with a timer to allow time controlled drying. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.

Wet /Tank Blotting System

Wet /Tank Blotting System

One of the most common techniques in modern biological laboratories is Wet/ Tank Blotting System. The technique requires the electrophoretic transfer of proteins that have been electrophoretically separated on a polyacrylamide gel to nitrocellulose or other types of membrane. The transfer can be performed either in wet conditions. The SD Semi-Dry Electrophoretic Transfer Cell is a very efficient, highly reproducible blotting system, especially for proteins with low molecular weight. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.

ECL Plus Western Blotting Substrate

ECL Plus Western Blotting Substrate

ECL Plus Substrate is an acridan-based chemiluminescent and chemifluorescent substrate to detect peroxidase activity from HRP-conjugated antibodies and probes by Western blotting using X-ray film, CCD or laser-based imagers. Pierce ECL Plus substrate generates acridinium esters when it reacts with HRP. As these ester intermediates react with peroxide, they produce a strong and sustained chemiluminescent signal that can be captured by X-ray film CCD imaging. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.

Western Blotting Substrates

Western Blotting Substrates

West Dura Substrate is a luminol-based enhanced chemiluminescence (ECL) HRP substrate for Western blotting that provides very stable light output especially for documentation with CCD camera imagers. West Dura Extended Duration Substrate for HRP is optimized for high sensitivity and long signal duration, making it ideal for cooled-CCD camera detection systems. Unlike other substrates, whose signal declines to undetectable levels in 30 to 60 minutes, the signal produced with West Dura Substrate is stable for several hours, allowing multiple camera (or film) exposures to be made. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.

PVDF Membranes And Nitrocellulose Membrane

PVDF Membranes And Nitrocellulose Membrane

PVDF Membranes are sheets and rolls of high-quality poly vinylidene difluoride membrane that provide high binding capacity for proteins and nucleic acids for Western, Southern and Northern blotting methods. These PVDF (polyvinyl difluoride) membranes are more resistant to discoloration than other commercially available PVDF membranes and have better retention of absorbed proteins than other types of transfer membranes used for western blotting, including nitrocellulose. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.

X-Ray Film

X-Ray Film

We offer high quality x-ray films. Our top priority is to provide you with the best price on x-ray film and supplies along with great service and quickest turnaround times. Our goal is to offer you top quality x-ray products. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.

Western Blot Signal Enhancer

Western Blot Signal Enhancer

Western Blot Signal Enhancer is a two-reagent system for conditioning protein blots after transfer to greatly enhance the effectiveness of primary antibodies and intensify the final detection signal in Western blot experiments. The Western Blot Signal Enhancer membrane treatment procedure is very simple, takes only 15 minutes and can be added to nearly any existing Western blotting protocol. The result is an increase in the intensity of target protein bands on the Western blot or detection of target proteins at levels that were previously not possible. We are looking for queries from Chandigarh, Panchkula, Mohali, and Punjab.

RELATED COMPANIES

Indiamart

Terms of Use - Privacy Policy - Link to Us

Copyright © 1996-2014 IndiaMART InterMESH Ltd. All rights reserved.