Available with us are online UPS that are manufactured as per the latest technology. These online UPS systems are widely acclaimed by our customers in various industries for their high quality, reliable performance and durability.

Industrial UPS With Power Factor Correction

Industrial UPS With Power Factor Correction

Along with our range of high quality UPS systems, we also manufacture and supply top of the line Industrial UPS with Power Factor Correction. These industrial UPS we are providing are made from premium quality materials fitted with latest microprocessors to enable highly efficient and convenient use. Our industrial UPS are tested in several parameters to ensure superior durability and unmatched functionality. We are offering these high quality industrial UPS with power factor correction to our clients at very reasonable prices.

 

Features:

 

  • Easy to use
  • Long lasting
  • Excellent durability
  • Highly efficient and functional

Power Factor Correction UPS

Power Factor Correction UPS

We are engaged in manufacturing and supplying top quality range of Power Factor Correction UPS. These power factor correction UPS are very useful for various commercial establishments and offices who needs continuous power for mainframe and computers. Made from advance technology, our power factor correction UPS are highly admired by our clientele for its excellent efficiency, superior functionality and durability. Avail from us our quality tested power factor correction UPS at very affordable range of prices.

 

Features:

 

  • Energy efficient
  • Supreme quality
  • Trouble free operation
  • Low maintenance

Power Factor Correction Online UPS

Power Factor Correction Online UPS

The BLULINE technologies introduce Online UPS System with Power Factor Correction. It’s consists of the most advance features and technology than normal double conversion UPS systems. Our Online UPS System is the one of the indigenous machine which is most advanced technology with 100% trouble free operation. It provides end to end power quality solution for all industry. With our comprehensive range of system, the capacity starts from 1KVA 1 phase to 150 KVA 3 phase with inbuilt Isolation Transformer.

 


Topology :


A problem in the combination of a "double conversion" UPS and a generator is the voltage distortion created by the UPS. The input of a double conversion UPS is essentially a big rectifier. The current drawn by the UPS is non-sinusoidal. This can cause the voltage from the AC mains or a generator to also become non-sinusoidal.
The voltage distortion then can cause problems in all electrical equipment connected to that power source, including the UPS itself. It will also cause more power to be lost in the wiring supplying power to the UPS due to the spikes in current flow. This level of "noise" is measured as a percentage of "Total Harmonic Distortion of the current"(THD-i). Classic UPS rectifiers have a (THD-i) level of around 25–30%. To reduce voltage distortion, this requires heavier mains wiring or generators more than twice as large as the UPS. There are several solutions to reduce the (THD-i) in a double conversion UPS.


Power Factor Correction (PFC):


An alternative solution is an active filter. Through the use of such a device,(THD-i) can drop to 5% over the full power range. The newest technology in double conversion UPS units is a rectifier that doesn't use classic rectifier components (thyristors and diodes) but high frequency components. A double conversion UPS with an IGBT rectifier and inductor can have a (THD-i) as small as 2%. This completely eliminates the need to oversize the generator (and transformers), without additional filters, investment cost, losses, or space.

 

Digital Technology:


Microprocessor based digital control ensures pure and perfect sine wave output delivering accurate voltage and clean power. It increases speed and efficiency of power conversion and facilitates communication interface between the machine and the user.


Double Conversion Topology (With Galvanic Isolation):


This UPS topology provides complete isolation from the incoming distribution system and the load at the UPS output. Continuous protection of load is provided from the Inverter, whether it originates from AC-input supply or the battery. Wide input voltage tolerances, precise regulation of the output voltage and frequency and a no-break transfer to bypass mode are the other main benefits with double conversion.


Active Power Factor Correction: 


The advanced technology used in the rectifier section with active power factor correction reduces power consumption by 30%. It reduces input current as well as voltage harmonics and helps to considerably downsize the generator or utility power rating. It has a soft-start feature to avoid in rush current.


Features:


Online Double Conversion topology assures maximum reliability IGBT rectifier UPS design High frequency technology allows perfect sine wave output<97% High efficiency Intuitive front Panel LCD display for consistence status indication with 100 error logs0.8 power factor output

Solar Off Grid Online UPS System

Solar Off Grid Online UPS System

Grid Input
Input Voltage Range :

  • 200-250V for single phase
  • 360-440V for three phase




Solar Input

DC Voltage

  • 84V to 150V
  • 110V to 200V
  • 240V to 400V
  • 360V to 600V




Converter Section (Grid)

Converter Type : IGBT high frequency ,MPPT technology
Battery Charging Current : As per the Battery Rating
THD Level :

  • <3% On Linear Load
  • <5% On Non-Linear Load

Input Power factor correction :

>.86 for single phase
>.98 for three phase



Inverter Section
Type Of Inverter : IGBT Based PWM High Frequency
Output Waveform : Pure Sine wave
Output Frequency : 50Hz +/- 0.5 Hz
Output Power Factor : 0.8 Lagging to Unity
Inverter Efficiency : >90%
Over load Capacity : 100% to 120% for 30 sec



Battery Bank
DC Voltage : 84V,110V,228V,336V,360V,420V

LCD Metering

  • System Status

  • Load On Solar

  • Load On Grid

  • Load On Battery

  • Mains On

  • Low Battery

  • Over Load



Readings:

  • Output Voltage

  • Output Frequency

  • Battery Voltage



Optional

  • Solar Voltage

  • Solar Current

  • Solar Power(KW)

  • Solar KWH

 

Online UPS System With Power Factor Correction

Online UPS System with Power Factor  Correction

The BLULINE technologies introduce Online UPS System with Power Factor Correction. It’s consists of the most advance features and technology than normal double conversion UPS systems. Our Online UPS System is the one of the indigenous machine which is most advanced technology with 100% trouble free operation. It provides end to end power quality solution for all industry. With our comprehensive range of system, the capacity starts from 1KVA 1 phase to 150 KVA 3 phase with inbuilt Isolation Transformer.

Topology:

A problem in the combination of a "double conversion" UPS and a generator is the voltage distortion created by the UPS. The input of a double conversion UPS is essentially a big rectifier. The current drawn by the UPS is non-sinusoidal. This can cause the voltage from the AC mains or a generator to also become non-sinusoidal.

The voltage distortion then can cause problems in all electrical equipment connected to that power source, including the UPS itself. It will also cause more power to be lost in the wiring supplying power to the UPS due to the spikes in current flow. This level of "noise" is measured as a percentage of "Total Harmonic Distortion of the current" (THD-i). Classic UPS rectifiers have a (THD-i) level of around 25–30%. To reduce voltage distortion, this requires heavier mains wiring or generators more than twice as large as the UPS. There are several solutions to reduce the (THD-i) in a double conversion UPS.

Power Factor Correction (PFC):

An alternative solution is an active filter. Through the use of such a device (THD-i) can drop to 5% over the full power range. The newest technology in double conversion UPS units is a rectifier that doesn't use classic rectifier components (thyristors and diodes) but high frequency components. A double conversion UPS with an IGBT rectifier and inductor can have a (THD-i) as small as 2%. This completely eliminates the need to oversize the generator (and transformers), without additional filters, investment cost, losses, or space.

Digital Technology:

Microprocessor based digital control ensures pure and perfect sinewave output delivering accurate voltage and clean power. It increases speed and efficiency of power conversion and facilitates communication interface between the machine and the user.

Double Conversion Topology (With Galvanic Isolation):

This UPS topology provides complete isolation from the incoming distribution system and the load at the UPS output. Continuous protection of load is provided from the Inverter, whether it originates from AC-input supply or the battery. Wide input voltage tolerances, precise regulation of the output voltage and frequency and a no-break transfer to bypass mode are the other main benefits with double conversion.

Active Power Factor Correction:

The advanced technology used in the rectifier section with active power factor correction reduces power consumption by 30%. It reduces input current as well as voltage harmonics and helps to considerably downsize the generator or utility power rating. It has a soft-start feature to avoid in rush current.

Features:

  • Online Double Conversion topology assures maximum reliability
  • IGBT rectifier UPS design
  • High frequency technology allows perfect sine wave output
  • <97% High efficiency
  • Intuitive front Panel LCD display for consistence status indication with 100 error logs
  • 0.8 power factor output


Product Code: With-Power-Factor-Correction

Power Saving UPS System

Power Saving UPS System

We are one of the prominent suppliers and distributors of UPS Systems to our customers across the globe. Our range is widely demanded in the markets for their superior quality, high performance, optimum service and long service life. These are accessed by our clients at reasonable prices in the market.

Solar Off Grid Online UPS System

1. When the  Solar power  is sufficient, then that DC will give to Inverter section and balance will given to charge the battery bank.

2 .When   the solar power is weak, then remaining  power will take through grid charger.

3. When the  Solar Power is absent, then total power will take from grid through grid charger.

4. When the grid supply is absent, then output load will work on battery bank, when grid supply is return the load will work on the grid supply and also the battery will charge on the grid supply.

5.If the both Solar and Grid supplies are absent then inverter will run under battery made.


B. TECHNICAL SPECIFICATION
General
 Model                            : Blue Power
 Operating Mode              : Off-Grid
 System Type                  : On-Line
 Duty Cycle                      : 100%  Continuous
 Change Over Time          : NIL
 Noise Level                     : 50db at IM Distance
 Operating Temperature    : 40 Dec C  Max Above Ambient
 Environment                    : Designed For Indoor use(IP 22&23)
 Mounting                        : On Wheels
 Enclosure                        : Powder Coated
 Insulation                       : Class”B”
 1 In 1 Out Rating             : 2Kva,3Kva,4Kva,5Kva,6Kva
 3 In 1 Out Rating             : 7.5Kva,10Kva,15Kva,20Kva,25Kva,30Kva,
                                      :  40Kva,50Kva
 3 In 3 Out Rating             : 3Kva,6Kva,7.5Kva,10Kva,15Kva,20Kva,30Kva             
                                      :  40Kva,50Kva,60Kva,75Kva   