 |
|
Leading Manufacturer and Exporter of Gas Mixtures such as Laser Gas Mixture, Medical Gas Mixture, Instrument Gas Mixture, Hydrocarbon Gas Mixtures and Calibration Gas Mixture from Bengaluru.
|
 
 

| Laser Gas Mixture
| 4.5% Carbon Dioxide, 13.5% Nitrogen in Helium | CG112503000 | | 2-4% Carbon Monoxide, 6-8% Carbon Dioxide, 6-8% Nitrogen in Helium | CG122504000 | | 4% Hydrogen, 5% Nitrogen, 15% Carbon Dioxide in Helium | CG292504000 | | 0.4 Hydrogen, 4% Carbon Monoxide, 8% Carbon Dioxide, 8% Nitrogen in Helium | CG292505000 | 
|
 
 
 

| Medical Gas Mixture
| Clinical Blood Gas Mixture | | | 0.5 – 12% Carbon Dioxide in Nitrogen | CG114702000 | | 3 – 12% Carbon Dioxide in Oxygen | CG125402000 | | 3-12% Carbon Dioxide, 5-23% Oxygen in Nitrogen | CG114703000 | Pulmonary Function Testing / Lung Diffusion Gas Mixture
| | | 900-1000 ppm Carbon Monoxide, 21% Oxygen in Nitrogen | CG124703000 | | 0.3% Carbon Monoxide, 10%Helium,21% Oxygen in Nitrogen | CG124704000 | | 0.4% Carbon Monoxide, 0.5% Neon, 0.5% Acetylene,21% Oxygen in Nitrogen | CG124705000 | | 1000 ppm Carbon Monoxide, 200 ppm Carbon Dioxide, 21% Oxygen in Nitrogen | CG124704111 | 
|
 
 
 

| Instrument Gas Mixture
| Electron Capture Detector Mixture | | | P-10, 10% Methane in Argon | CG360402001 | | P-5, 5% Methane in Argon | CG360402002 | | 8.5% Hydrogen in Helium | CG292502001 | | Flame Ionisation Detector Mixture | | | 40% Hydrogen in Helium | CG292502002 | | 40% Hydrogen in Notrogen | CG294702000 | | Nuclear Counter Mixture | | | P-10, 10% Methane in Argon | CG360402001 | | P-5, 5% Methane in Argon | CG360402002 | | 1.3% Butane in Helium | CG082502000, | | 0.95% Isobutane in Helium | CG312502000 | | FRC Test Mixture | | | 3% Ethane, 18%CO, 24%Methane in Hydrogen | CG192904000 | | Furnace Gas Mixture | | | 0.1- 10% H2 in N2 | CG294702000 | | 60?, 40%CO2 | CG111202000 | | 1-5%CO in N2 | CG124702000 | | Spark Chamber Gas Mixture | | | 10-20% Helium in Neon | CG254402000 | 
|
 
 
 

| Hydrocarbon Gas Mixtures
| Natural Gas Standard | | | 8.4 - 8.9% Ethane+ 5 - 6% C3H8+ 0.9-1.3% Iso-Butane + 1-1.6% N-Butane+ 0.2-0.4% N-Pentane+ 0.15-0.4% N-Hexane+ 1-2.3% CO2+ 0.2-0.5% N2 in CH4 | CG273609000 | | BTU Gas Mixture | CG004700000 | | LPG Mix Reference | | | 0.5% Methane+ 0.5% Ethane+0.5% Ethylene +30% Propane+ 4% Propylene+0.5% Propadiene +15% n-butane+5% 1-butene+ 0.5% cis-2-butene +0.75% trans-2-butene+1.5% 1,2-butadiene+ 1% 1,3-butadiene+4% iso-butylene+1.25% n-pentane+ 2% iso-pentane+ in iso-Butane | CG363116000 | | Transformer Oil Dissolved Gas Standard | | | 100 to 1000 ppm each of Methane + Ethane + Ethylene + Acetylene + 5000 ppm each CO+ CO2+1000 ppm H2 in N2 | CG024708000 | | Refinery Gas Standard | | | 1.5% Methane+ 2.5% Ethane+2.5% Ethylene +2.5% Propane+ 5% Propylene+3% Iso-butane +3% n-butane+3% 1-butene+ 3% trans-2-butene +2% H2+1% CO2+1% CO+2% Iso-pentane+ 2% n-pentane+ 60% N2 | CG114715000 | | Petrochemical References | | | 0.5% Propane +12.5% Propylene+7% Ethane +32% Ethylene+ 32% Methane+16% H2 | CG592306000 | | 95% Propylene + 5% Propane + 500 ppm Ethane + 25 ppm Methyl Acetylene + 25 ppm Propadiene + 500 ppm Butane + 50 ppm 1,3-Butadiene+ 50 ppm iso- Butane + 50 ppm Acetylene + 100 ppm isobutylene + 50 ppm Pentane | CG556011000 | | 0.15% Ethane+2.15% Propane+ 0.7% Propylene + 22% Iso - Butane+ 18% N - Butane+ 8.4% 1-Butene + 10.6% I-Butylene+ 9.6% T-2 Butene+ 7.5% C-2-Butene +0.5% 1,3-Butadiene+1% Iso Pentane + 0.05% Hexane | CG273112000 | | Hydrocarbon Liquid Mixture | | | 55% Benzene+23% 1-Butene+22% 1, 3 Butadiene | CL070503000 | | 0.8%1,3-Butadiene+10%cis-2-Bane+10% trans-2-butane+ 30% trans-1-butane+bal.iso-butylene | CL073205000 | | 54.5% Benzene+15% 1-Butene+7% cis-2-butene +0.5% T-2-Butene+ 23%1,3 Butadiene | CL650505000 | 
|
 
 
 

| Calibration Gas Mixture
Calibration Gas Mixture more emphatically a degree of measurement is our prime product. We request to discuss with us for any of your requirements. All our mixtures are filled using the most accurate and cost effective method available. Most of our mixtures are produced by gravimetric filling as per ISO 6142 where the components are added sequentially using traceable weights. This ensures that the expected tolerance requirements are always fulfilled. Manometer method as per ISO 6146 is another process adopted. Filling Tolerance and Certification Accuracy: The Filling Tolerance defines the maximum permitted variation between the requested nominal concentration and the actual concentration supplied. It depends mostly on characteristics of component gases. The Certification Accuracy defines the maximum permitted variation between the stated composition of the mixture on the certificate and the actual composition in the cylinder. Traceability: All our calibration mixtures are delivered with a calibration certificate compliant to ISO 6141 requirements. Due to our thorough approach to quality, we are able to trace every mixture back to its original filling data. We offer a wide range of customized Calibration gas mixtures made from the list of various chemicals within the limits of physics and chemistry: Acetone
| Dimethyl Ether
| Krypton
| 1-Octene
| Acetylene
| Ethane
| Methane
| 2-Octene
| Ammonia
| Ethanol
| Methanol
| Oxygen
| Argon
| Ethyl Acetate
| Methyl Acetylene
| n-Pentane
| Benzene
| Ethyl Benzene
| 2-Methyl-2-Butene
| 1-Pentene
| 1,2-Butadiene
| Ethylene
| 2-Methyl-1 -Pentene
| 2-Pentene
| 1,3-Butadiene
| Ethyl Methyl Ether
| 3-Methyl-1-Butene
| 1,3- Propadiene
| N-Butane
| Helium
| Methyl-Cyclo-Pentane
| Propane
| 1-Butene
| n-Heptane
| 3-Methyl Pentane
| Propylene
| Cis-2-Butene
| n- Hexane
| Neon
| Sulfur Dioxide
| Carbon Dioxode
| 1-Hexene
| Neo Pentane
| Sulfur Hexafluoride
| Carbon Monoxide
| Hydrogen
| Nitric Oxide
| Ter-Butyl Methyl Ether
| Cyclo Butane
| Hydrogen Sulfide
| Nitrogen
| Toluene
| Cyclo Hexane
| Isobutane
| Nitrogen Dioxide
| Trans-2-Butene
| 
|
 
|
Gas Mixtures Laser Gas Mixture Medical Gas Mixture Instrument Gas Mixture Hydrocarbon Gas Mixtures Calibration Gas Mixture Gas Handling Equipment Industrial Gases Medical gases Instrument Gas Mixture
 |