AUTOMATIC Battery Life Cycle Tester
Description:
Life Cycle Tester consist of precise timer, which changes the state of battery from discharging to charging and back to discharging at preset time interval. The test stops after the set No. of cycles reached. In case of power failure, the testing stops and when the power is resumed the testing starts from the point where it stopped.
Features:
Tests the batteries in accordance with ISI, DIN, SAE, JIS, IEC, BCI, BS etc.
For automotive, industrial and Maintenance free batteries.
Charge and Discharge 5-500A DC.
Designed with latest Micro-controller Technology.
7 Segment LED display and keyboard for programming and operation.
User-friendly program.
Simple to operate by non-technical person.
Visual indicators for Charge/ Discharge.
Audio/ Visual indicators for test stops.
Technical Specifications:
Discharge time: 1 min to 99hrs 59mins programmable by keyboard
Charging Time: 1 min to 99hrs 59mins programmable by keyboard
Rest Time: 1 min to 99hrs 59mins programmable by keyboard
No. of Cycles: 0-9999 cycles. Programmable by keyboard.
Mode testing: Charge/ Discharge/ Cycling Selectable.
Accuracy: 0.25 to 1.00% of FSD for Current, 0.10 to 0.25% of FSD for Voltage
Cycling :Charge-Rest-discharge-Rest, Discharge-Rest-Charge-Rest, programmable
Charge/ Discharge Termination : Programmable by preset Voltage/ preset time.
Display : By 7 segment LED, voltage, Current, Temprature-3 ½ digits. Real time, Elapsed Time, Cycles and Ampere-Hr.-4digits.
Data Logging: the data’s of voltage, Current AH and temperature with respect to time logged at selected time interval. Charge/discharge log time can be independently programmable. After the completion of the test, Logged datas can be printed out with the help of external printer. Data’s of up to six different voltages, one total voltage, one current, one temperature and one AH can be logged.
RS-232 Serial port: the logged data’s in the memory can be transferred to any IBM PC through RS-232 Serial port. The required software will be supplied.
Mains: 230V + 10% AC 50Hz./400V + 10% AC 3 phase 50 Hz.