IndiaMART.com
Company Directory  > Electronics & Electrical  > Electronic Components & Spares  >
Share:

Cooper Safety

Bengaluru, Karnataka

Year of Establishment: 1900
IndiaMART Member Since: 2009
Products [98]
Phone: +(91)-(80)-41303378

HOME

ABOUT US

PRODUCTS & SERVICES

CONTACT US

SEND ENQUIRY


Products & Services

Addressable Products (32)

Bi Wire (21)

Conventional (31)

Smoke & Heat Detectors (14)

Addressable Products

CF3000 and CF1000 Range User Interface

The main element of the user interface is a large (120mm
x 90mm visible area) touch screen display, which provides
comprehensive user information as well as acting as a
multifunctional keypad providing clear and precise user
controls and system information.

Comprehensive ‘help’ information is provided throughout the
menus to assist end users/system operators unfamiliar with
the panel operation.

To provide fast, simple text changes within the system, the
touch screen display reconfigures to a full QWERTY keyboard
when certain text functions are selected (for example, if the
change device text menu option is selected).

As well as a large format LCD display providing full system
status information, the panel incorporates 96 (CF3000 range)
or 16 (CF1000 range) zone indication LEDs to provide
information on the status and spread of any fire, even to a user
who is completely unfamiliar with the system. In addition there
are a number of system status LEDs designed to give clear
indication of the panel and system condition.

CF2000 User Interface

The user interface on the CF2000 is a graphic display which
provides comprehensive user information.

As well as the graphic display providing full system status
information, the panel has six ‘push to operate’ control
buttons which provide the various panel functions.
The panel also has 32 traditional zone indication LEDs to
provide clear information about the status and spread of
a fire even to a user who is completely unfamiliar with the
operation of the system. In addition there are a number of
system status LEDs designed to give clear indication of the
panel and system condition.

Printer (Optional on CF3000 range)

Access to printer, when fitted, is via a separate locked access
door. Paper can be changed by non skilled engineer without
exposure to any live components.

The printer can either be set to print on demand or
to automatically print all system events as they occur.

Detection Capacity

Up to 200 addresses per loop can be installed, which
can be a mixture of call points, detectors, interfaces or
loop sounders.

Addressable Products


230V Relay I & O Unit & Interface

230V Relay I & O Unit & Interface
230V Relay I/O Unit/Interface

 
 

4 Way Sounder Controller & Interface

4 Way Sounder Controller & Interface
4 Way Sounder Controller/Interface

 
 

Base Sounders

Base Sounders
The CAS380 is a loop-powered integrated sounder and
sensor mounting base. It can be used with any analogue
sensor or as a standalone sounder with the optional
CASC cover plate

 
 

CAB300 Common Detector Base

CAB300 Common Detector Base
This is the common mounting base for our analogue sensors.

 
 

CAS381 Wall Sounder

CAS381 Wall Sounder
The CAS381 range of loop-powered addressable wall
sounders offers a highly efficient, low current sounder
option. Sounder volume and tone are set at the analogue
panel avoiding the need to access each sounder
individually to alter settings.

 
 

CAS382 & LED Beacons

CAS382 & LED Beacons
The CAS382 loop-powered addressable beacon offers
high efficiency LED technology together with a low profile
design for a discreet installation. The beacon is designed
to provide a visual indication in areas of high ambient
CASBB384 noise or where people may be hard of hearing.

 
 

CASB383 & Sounder Beacons

CASB383 & Sounder Beacons
The Cooper Fire range of loop-powered addressable
wall-mounted sounder beacons offer a highly efficient,
low current sounder beacon option. Sounder volume
and tone are set at the analogue panel avoiding the need
to access each sounder individually to alter settings.

 
 

CASBB384 & Sounder Beacons

CASBB384 & Sounder Beacons
The CASBB384 is a loop-powered, integrated
sounder/beacon and sensor mounting base. It can
be used with any analogue sensor or as a standalone
sounder with the optional CASC cover plate.

 
 

CBG370 Callpoints

CBG370 Callpoints

The Cooper range of addressable callpoints are available
as surface, flush and weatherproof versions.
All callpoints have integral short circuit isolators and have
a status LED fitted as standard. To simplify replacement
of glass element callpoints are fitted with fast fit clip on
front covers.

Features

  • Approved to EN54 pt11
  • Soft addressing
  • Integral short circuit isolators
  • Glass or re-settable elements
  • Weatherproof version IP67

 
 

CF1000 Panel

CF1000 Panel

The Cooper CF1000 range of analogue fire detection
panels are available as 1 and 2-loop configured panels.
They provide sophisticated ‘touch screen’ functionality
yet achieve a simple end user interface operation within
a compact panel design.


The CF1000 range of panels provide a large (120mm x 90mm)
touch screen display as the main user element, eliminating the
need for dedicated system push buttons. The user interface is
menu-driven, automatically reconfiguring to suit the chosen
menu option. To enable text updates directly at the panel, the
display converts to a full QWERTY keyboard, enabling
comprehensive text insertion.

The panel also has 16 zone fire LEDs providing additional
information about the extent of any fire activation as well as a
comprehensive set of system status LEDs providing additional
visual information for the end user.

The CF1000 range supports a complex cause and effect
programming ability which, together with a wide range of user
controllable functions, makes the panel suitable for a wide
range of projects.

As with all Cooper analogue panels the CF1000 range uses
‘spur tolerant’ soft addressing thereby minimising installation
time and removing the potential for errors often associated with
other forms of system addressing.

As with the entire range of Cooper analogue panels, the
CF1000 range of panel system components have been
specifically designed to operate as part of an integrated system;
this provides an assurance that the panel, sensors, interfaces
and other ancillaries are all fully compatible with each other
and that the full range of system functionality is supported by
each device.

Features

  • Large versatile touch screen display
  • 1 and 2-loop panel versions
  • Spur tolerant soft addressing
  • Short circuit isolators incorporated into every loop device
  • Up to 200 addresses per loop
  • Network capable with CF3000 and CF2000 range fully monitored up to 126 panels
  • Integral power supply
  • Large selection of compatible ancillaries
  • Compliant to EN54 parts 2 & 4

 
 

CF2000 Panel

CF2000 Panel

The Cooper CF2000 panel is an entry level two-loop
analogue fire detection panel which can be configured
for 1 or 2-loop operation.


The panel has a 126mm x 64mm graphic display which
provides a simple yet comprehensive, menu-driven, end
user interface.

With the panel’s ability to support complex cause and effect
programming and a wide range of user controllable functions it
makes the panel suitable for a varied range of projects from
small warehouses to small/medium office developments as well
as many small industrial applications.

As with all Cooper analogue addressable panels, the CF2000
uses ‘spur tolerant’ soft addressing to minimise installation time
and remove the potential for errors often associated with many
forms of manual addressing.

All of the CF2000 fire detection system components have been
specifically designed to operate as part of an integrated system;
this provides an assurance that the panel, sensors, interfaces
and other ancillaries are all fully compatible with each other
and that the full range of system functionality is supported by
each device.

Features

  • LPCB and BOSEC 3rd party approved to EN54 pts. 2 and 4
  • Choice of 1 or 2-loop panel operation
  • Menu-driven graphic screen
  • Spur tolerant soft addressing
  • Short circuit isolators incorporated into each loop device
  • Up to 200 addresses per loop
  • Network compatible with CF1000 and CF3000 fully monitored up to 126 panels

 
 

CF3000 Panel

CF3000 Panel
It combines sophisticated functionality, yet simple panel
operation with a very aesthetically-pleasing design.

The large capacity, ability to support complex cause and effect
programming and wide range of user-controllable functions
make this panel suitable for a wide range of projects from
sheltered housing to large office developments as well as many
industrial applications.

The CF3000 range of panels provide a large (120mm x 90mm)
touch screen display as the main user element, eliminating the
need for dedicated system push buttons. The user interface is
menu-driven, automatically reconfiguring to suit the chosen
menu option. To enable text updates directly at the panel, the
display converts to a full QWERTY keyboard, enabling
comprehensive text insertion.

The panel also has 96 zone fire LEDs providing additional
information about the extent of any fire activation as well as
a comprehensive set of system status LEDs providing
additional visual information for the end user.

The panels use ‘spur tolerant’ soft addressing to minimise
installation time and remove the potential for error normally
associated with manual addressing.

All of the CF3000 fire detection system components have been
specifically designed to operate as part of an integrated system;
this provides an assurance that the panel, sensors, interfaces
and other ancillaries are all fully compatible with each other
and that the full range of system functionality is supported by
each device.

Features

  • LPCB 3rd party approved to EN54 pts. 2 and 4
  • VdS, BOSEC, CNBOP
  • Choice of 1, 2 and 4-loop panel options
  • Large multi functional touch screen
  • Spur tolerant soft addressing
  • Short circuit isolators incorporated into each loop device
  • Up to 200 addresses per loop
  • Fully monitored network capable up to 126 panels
  • Network compatible with CF1000 range and CF2000 range of panels
  • Optional integral printer

 
 

CIO351 3 Channel I O Unit Interface

CIO351 3 Channel I O Unit Interface
CIO351 3 Channel I/O Unit/Interface

 
 

CSI350 Spur Isolator Unit & Interface

CSI350 Spur Isolator Unit & Interface
CSI350 Spur Isolator Unit/Interface

 
 

CSUM355-Interface

CSUM355-Interface
CSUM355/Interface

 
 

CZMU352 Zone Monitor Unit & Interface

CZMU352 Zone Monitor Unit & Interface
CZMU352 Zone Monitor Unit/Interface

 
 

LED Repeater PCB

LED Repeater PCB
  • Can be loop connected or network connected
  • Each LED can be programmed to operate by zone or
    by address for fire or fault indication using PC repeater
    download software
  • Up to 5 different zones can be programmed per LED
  • General fire, fault, local power fault & system fault
    LED provision
  • Test lamp button

 
 

Loop Splitter

Loop Splitter
  • Unit is loop connected
  • Splits each connected loop into 4 smaller loops
    (max 50 devices per loop)

 
 

MCIM-C Single Input Module

MCIM-C Single Input Module
MCIM-C is a compact input module used to accept input
signals from external equipment such as beam detectors,
flow switches, valve monitor switches etc

 
 

MCOM-S Single Output Module

MCOM-S Single Output Module
MCOM-S is a compact output module used to control or
signal external equipment such as access control systems,
lift positioning etc

 
 

Remote Indicator

Remote Indicator

The MRIAD provides remote indication of a detector. It is commonly
used if a detector is out of sight for example in a locked room.

  • High Brightness LED
  • Easy to install

 
 

Repeater Panels

Repeater Panels

The Cooper analogue system repeater panel is
available as a loop-connected panel (CF3000PRG)
or as a network-connected panel (CF3000PRGNC).


When connected to a panel loop, the host panel text
information is downloaded manually at time of system
commissioning using ‘site installer’ software. If the repeater is
network connected all text is transmitted via the network and
is automatically updated should any changes be made to
any of the network panels.

Both repeater panels are fully compatible with the extensive
range of Cooper analogue panels.

Features

  • 2x40 backlit LCD display
  • Loop or network connected
  • Silence alarm, evacuate and reset
    commands from repeater

 
 
Other products & services we offer
4 To 20mA PCBs
4 to 20mA PCBs
4 To 20mA Relay Outputs
4 to 20mA Relay Outputs
LED Output PCB
LED Output PCB

Relay Output PCB
Relay Output PCB

DF6000NETKIT/Interface
EC400/Interface
EC405MD/Interface
EC450/Interface
EC540/Interface
EC700/Interface

 

Related Product Catalogs

Brass Grip, India
Manufacturer and exporter of electronic component which includes brass electronic components, industrial electronic components, precision electronic components and engineered electronic components.

View more details

Cendrop Multilub System Private Limited
Manufacturing and exporting electronic timers, adjustable electronic controllers timer, electronic controllers timer, precision adjustable electronic controllers timers and lubrication system electronic timer.

View more details

Shirke Electro Private Limited
Manufacturer and supplier of electronic starter which includes power electronic starter, automatic electronic starter, customized motor starter,, fully automatic electronic starter, manual star delta electronic starter and electric motor starter.

View more details

Suggested Companies


Related Categories
Search Suppliers
CompanyProductsTrade Leads
OR


IndiaMARTCompaniesProductsTrade LeadsTendersTrade ShowsTravel
© 1996-2012 IndiaMART InterMESH Limited. All rights reserved worldwide.