We are engaged in manufacturing and supplying Ampere Hour Meters, programmable amp-hour meters, programmable amp-minute meters etc that are widely appreciated by our clients from all over the world. These include Programmable Amp-Hour Meter, Programmable Ampere Hour & Minute Meter and Ampere-Hour & Minute Meter. Some of these are available with separate displays to properly meet the requirements of our clients. Our range of programmable amp-hour meters, programmable amp-minute meters etc encompasses following:

Ampere-Hour/Minute Meter - Model 804AH

We are engaged in manufacturing Ampere-Hour & Minute Meters Model 804AH, that are designed and developed aesthetically with membrane switches for the front panel. These are offered with shunt calibration programmable of up to 9999 for 75 mV. We also offer separate displays for current and ampere-hours per min. Following are some of the features and specifications of our Ampere-Hour & Minute Meter Model 804AH:


  • Ampere-Hour/Minute selectable

  • Cumulative Ampere-Hour stored on power failure

  • Settable limit for Ampere-Hours

  • Dual time relays with on time settable

  • Rear calibration lock to prevent tampering with settings


Specifications:

 

<!-- @page { size: 8.5in 11in; margin: 0.79in } P { margin-bottom: 0.08in } -->

Display

  • 4 Digit 7 Segment Red LED display for Current

  • 6 Digit 7 Segment Red LED display for Ampere-Hours/Mins

  • 2 Red LEDs to indicate status of the 2 Relay contacts

Shunt Calibration

  • Maximum 9999 Amps corresponding to 75mV settable from front panel

Set Point

  •  
    • Settable from 0-999999

Resolution

  •  
    • 1AH/0.1AH/1AM/0.1AM

Totaliser

  •  
    • 6 Digits for Ampere-Hour or Ampere-Minutes

Time Relays

  • 2 relay contacts with individual time settings in Min.:Sec.

Contact Rating

  • NO-P-NC @ 5Amps/220V AC

Memory

  • Settings and Ampere-Hours saved in solid state EEPROM

Lock

  • By rear jumper to prevent accidental tampering with settings

Supply

  • 220V AC  10% @ 50/60Hz

Size

  • Front Fascia 96 mm x 99 mm Depth 135mm. Cut Out: 91 mm x 91 mm.

Weight

  • 800 grams


Ampere-Hour/Minute Meter - Model 804AH

Send Your Enquiry

Programmable Amp-Hour Meter - Model 800AH

Programmable Amp-Hour Meter - Model 800AH

We offer Model 800AH Programmable Amp-Hour Meter, that is used for electroplating thickness control and testing battery Amp-Hr. These meters are available with 6 RED 7 Segment LEDs of 0.56” character height. However, the current display is fixed at Max 9999 Amps using a shunt of current & 75mV for user programmed. Following are some of the features of our Model 800AH Programmable Amp-Hour Meter:


  • Shunt calibration programmable

  • Stores cumulative Amp-Hour

  • Instantaneous current display

  • Settable Limit for Amp-Hr/Min

  • Front membrane switches for easy operation

  • Non-volatile memory for storing settings, hence no battery required


Further, our Model 800AH Programmable Amp-Hour Meter has below mentioned technical specifications:


  • Amp-Hour: Max 9999 A-H for each preset cycle. (Amp-Hour range is selected by shorting Pin 17-18 at the rear)

  • Amp-Minute: Max 9999 A-Min for each preset cycle. (Amp-Minute is selected, opening the link between Pin 17 & 18).

  • Max shunt: Max value of 9999 Amp corresponding to 75mV

  • Totalize: 6 Digits for Amp-Hour or Amp-Min. i.e. 99, 99, 99. (readable for 10 sec by going into ‘total’ mode)

  • Limit: Up to 9999 AH or Amin. Setting (In limit mode using incr. & decr. switches).

  • Relay Contact: One NO-P-NC of 5 Amp rating.

  • Trigger start: By pressing front panel switch or closing a rear external contact.

  • Battery Back-Up: Not required. Programmed values & readings, including A-H stored in EEPROM.

  • Lock: Electronic lock for calibration (open link between Pin 1 & 2 to lock CAL) Low Volt.

  • Trigger: Set at 10.5V internally, for testing 12V Battery AH. (With Pin 3 & 4 shorted)

  • Increased Res.: 0.1AH or 0.1AMin facility by shifting internal jumper

  • Supply: 220V AC  10%

  • Size: Front Fascia 96 mm x 96 mm, Depth 135 mm, Cut Out: 91 mm x 91 mm.

  • Weight: 800 grams

Send Your Enquiry

Programmable Ampere Hour/Minute Meter - Model 803AH

We provide Programmable Ampere Hour & Minute Meter Model 803AH, that is in sync with set industrial benchmarks. These meters are perfect for ensuring electroplating thickness by presetting AMP-HOUR. Owing to the quality, these are considered to be valuable for checking Amp-Hour of rechargeable batteries using voltage limit. Further, our Programmable Ampere Hour & Minute Meter Model 803AH is offered with different displays for Voltage, Current and Amp-Hour. Following are some of the features and specifications of our Programmable Ampere Hour & Minute Meter Model 803AH:


  • Programmable for AH/0.1AH/AMin/0.1AMin

  • Usable with any shunt by setting ‘Calibration’ for Amp-75mV

  • Calibration factor lockable from rear

  • 4 Digit Amp-Hour and 6 Digit cumulative Amp-Hour display

  • Attractive front panel membrane switches in rugged Aluminum cabinet.

  • In case of power failure, the current status of selected parameters, the current Amp-Hour and Cumulative Amp-Hour is saved.


Technical specifications:

<!-- @page { size: 8.5in 11in; margin: 0.79in } P { margin-bottom: 0.08in } -->

Displays

All of 0.56in character height Red 7 Segment displays are:

  • 3 Digits to display voltage 0 – 99.9V

  • 4 Digits to display current 0 – 999.9Amps

  • 6 Digits to display Amp-Hour (4 Digit) and cumulative Amp-Hour (6 Digit)

Max. Shunt

  • Max. Value of 999.9 Amps corresponding to 75mV. User programmable from front in ‘CAL’ mode. (Max. value of 9999Amps also available on request)

Selection of Amp Hour/Min

  • Short Pin 17-18 for Amp-Hour

  • Open link of Pin 17-18 for Amp-Minute

0.1AH/AMin

  • Higher 0.1 resolution by shifting internal jumper by opening cover

Totalize

  • 6 Digit readable in ‘Total’ Mode

Limit

  • Up to 9999 AHR/AMIN settable in limit mode using increment/decrement switches

Relay

  • NO-P-NC of 5 Amp at 220V AC contact rating

Start

  • Pressing front panel switch or momentarily shorting rear Pins 5 & 6 by wiring an external switch.

Memory

  • Non-volatile EEPROM solid state memory. Stores programmed value of shunt, preset value, current Amp-Hr and the current Cumulative Amp-Hr to preserve current status on power failure

 