Size: 1/2 to 4 Valve body: AVP 4 / Aluminium Primary regulation: screw brass Secondary regulation shaft: AISI303 Electric control support: iron Push rod: brass Max. Operating pressure: 500 mbar Max. Fluid temperature: 60°C
Applications Valve for air and gas flow regulation. The port is used to adjust the flow. Throttle valve with leak in FULL-CLOSED configuration is less than 5percent
16 to 1500 kW Turndown range 10:1 Fuel: Natural Gas/Propane/LPG/Coke Oven/BF /Producer Gas Max. Air pressure at the burner 70.4 mbar Operation with Preheated air up to 450°C Burner's refractory block operating temperature up to 1750°C Low Nox Levels
Applications
Annealing furnace Zinc Melting Pot furnace Cone and Pit furnace Reheating furnace Aluminium Melting furnace
Size : ¾inch. to 4inch. Valve body : cast iron Valve seat : cast iron Piston and rising stem : galvanized AVP Cap aluminium O ring seal Max operating pressure : 350 mbar Fluid temperature : 30°C to 180°C
Applications
Manual adjustment valve even at reduced flows. Non sealing valve. Recommended for non-corrosive gases such as Natural Gas, LPG, Air, Nitrogen
Size Range ½” to 6” Skid Mounted Pre-Piped, Pre-Wired & Pre-Tested Assembly. Suitable for Natural Gas / Propane / LPG. Suitable for gas pressures upto 4 bar, high pressure options available on Request. Standard or Tailor Made to suit your Specific applications. Built as per most stringent global standards such as EN/IRI guidelines. Higher sizes can be made available on request. Gas and Air Train can be mounted on Single skid if required. Leak test and Functional Test conducted before dispatch. Components used are of highest quality standards and safety.
10 to 3750 kW. Turndown range 10:1 Fuel : Natural Gas/Propane/LPG/Coke Oven/BFG/ Producer Gas. Air and gas pressure at the burner - 44 mbar Operation with Preheated air upto 450°C Burner's refractory block operating temperature up to 1750°C Separated gas and air inlet, no flashback
Applications
Reheating furnace Continuous galvanising/Annealing furnace Melting furnace Forging furnace Heat Treatment furnace High Temperature furnace Laddle Heating
1 to 525 kW Can burn any standard fuel gas at mixture pressures ranging from 2.54 mm WC to 1524 mm WC, easily lighted at stated mixture pressures. Long annular orifice reduces back firing even at lower mixture pressures. Shorter flame length & higher heat release (On Standard Blocks) Pilot tip edge is screwed in the body to ensure permanent and correct location of pilot flame. Integral flanged units are available for pressurized furnaces.
30 to 300 kW Turndown range 10:1 Fuel: Natural Gas/Propane/LPG/Producer Gas Air & Gas pressure at the burner 45 mbar Electrodes can be easily replaced. Operation with Preheated air upto 450ºC Separated gas and air inlet, no flashback
Size : 1.1/4inch. to 6inch Flange construction : No pipe union required. Construction: Cast Iron Fuel: Natural Gas/Propane/LPG Internal pipe and orifice : SS 304 High capacity with low pressure drop
Applications Mixer for high capacity premix burner
Size: 1/2 to 6 Threaded flange : Cast Iron Welded flange : Iron Orifice Port : Iron Max. Operating temperature : 400° C Max. Operating pressure : 350 mbar
Applications To measure flow of air and gas To measure pressure drop for calibration of burner.
Centrifugal air blower 5 H.P to 150 H.P Volume range: 100 to 20,000 m³/hr Stage: single/twin/multi stage. Type of drive: Direct driven/V-belt driven/coupling driven
Applications
It is used for supplying combustion air, atomizing air and dilution air for industrial combustion system
Size: 3/4inch. to 8inch. Economical manual flow control valve. For most fuel gases and air. Double bearing shaft positive alignment O ring sealed shaft. Thumb screw lock holds disc position. Adjustable limit stops both high and low flow. Disc position indicator on name plate. Cast iron body and steel disc. Large, easy grip dial handle
Voltage : 115 / 230 VAC, 50/60 Hz Voltage by request : 24 / 12 VAC / VDC Size: 3/8inch. to 4inch. Max. operating pressure 200 mbar or 360 mbar. Optional G-1/8 connection for closed position. Other gauge points on request. Indicator micro switch (on request from ¾ to 6) Large range for inlet outlet connection. Protection : IP 54
Applications Suitable for gas burner Suitable for gas blocking and releasing controls gas burner
Specially configured control panels can be designed and manufactured to meet the demands for any type of standard and customized application for Industrial Combustion Systems and Thermal process equipments. Creative design with consideration for type of duty, varied painting and end finish requirement, also provide very good safety features as per systems. Panels are Pre-wired and Pre-tested. Standard IP44 / IP52 enclosures (IP54/IP55 enclosures with options of double door can be provided on request) Panels can be designed with front rear access, cable entry or any other combination Offer complete range of Panels such as Customized Relay Panels, Tailor made Burner Ignition Panel, MCC and Instrument Panel, VFD Panel and PLC Panel with Scada System. Standard voltages 115 / 230 / 415 VAC, 50 Hz
16 to 1700 kW. Turndown range 10:1 Fuel : Natural Gas/ Propane/LPG/Coke Oven/BFG Air pressure at the burner - 25 mbar Gas pressure at the burner - 10 mbar Operation with Preheated air upto 450°C Burner's refractory block operating temperature upto 1750°C Separated gas and air inlet, no flashback Over 800percent excess air
Applications
Heat treatment furnace Low Temperature furnace Annealing furnace Stress Relieving furnace Hot Air Generator Laddle Heating
30 to 600 kW Turndown range 10:1 Preheated Air up to 400 º C Fuel: Natural Gas/Propane/LPG Excess Air Over 400percent. Separated gas and air inlet, no flashback. Optional: Refractory burner block available
Supply voltage: 115 or 230 VAC, 50/60Hz Working temperature: 0 ºC to 60ºC. Storage temperature: -20 ºC to 80 ºC. Panel seating: IP 54. Mounting position: vertical (via M4 threaded holes) Not suitable for corrosive and explosive environment. Flowrate temperature compensation model available
Applications Measurement of differential and relative pressure. Measurement of flow through calibrated orifice with temperature and pressure compensation. Resetable totalizer
Spectral response : 185-260 nm Peep sight connection : ø ¾” gas Discharge starting voltage : (with UV radiation) 280V Recommended operating Voltage : 400V (max) Recommended discharge current : 100µA Average discharge current : 1 mA Max. Peak current : 30mA Operating temperature : 20°C to 60°C Life service with continuous discharge: 10,000 hours
Integrated Electrolife System Established in 1997 we are a leading manufacturer and exporter of on-line ph meters, ph transmitters, combined ph electrodes and water level transmitters.
Analab Scientific Instruments Private Limited Manufacturer and supplier of ph meters, digital meters, digital ph meters, electronic meters, flame photometers, electronic digital pH meters and micro digital pH meters.