The Remote indication panel is installed in security rooms, fire stations, which will repeat fire/fault indications registered in the Main fire alarm panel.
The response indicator enables auxiliary indication for Smoke detectors that are located in closed spaces (ie., not Visible), for example, above false ceilings inclosed rooms.
FEATURES : Fully confirms IS 2189 Modular construction Battery backup with build-in-charging Low battery/battery fail warning audio/visual indication AC fail audio / visual warning Charger fail audio / visual warning Relay output for actuators. Lamp test facility One man Walk Test facility Compatible to all types of conventional detectors Twin RED LED indication for fire Zone isolation facility with loop voltage out off 24 V DC output for External notification devices (sounder, Bell, etc..,) User, Installer & maintenance facility TECHNICAL SPECIFICATIONS :
No. of Zones
4 to 64 Zones
Primary power
230V AC, 50 Hz
Standby power
24v DC
Zone input
2 wire loop with 4k7 End of Line Resistor [ EOL ]
Standard indication
System On/Ac/ On/Battery/ Charge On/Walk Test/Auxiliary Trip/Earth fault
FEATURES : Fully confirms IS 2189 Modular Construction Battery backup with built-in-charging Error free Fire/Fault status in unambiguous colored LED indication 20 x 4 LCD Dot Matrix display Low battery/battery fail warning audio/visual indication Charger ON indication AC fail audio/visual warning Relay output for actuators Output for remote repeater panel Lamp test facility One Man Walk Test facility Compatible to all types of conventional detectors Separate Twin LED indication for fire Zone Isolation facility with loop voltage out off Password Protected authorized access 24 VDC output for External notification device (Sounder, Bell, etc.) Optional Loop Sounders Optional Twin LED for MCP activation
LCD DISPLAY :
Alpha numerical 4 x 20 characters illuminated display indicating major events, alarm, trouble etc.
TECHNICAL SPECIFICATIONS :
No. of Zones : 4 to 64 Zones
Primary power : 230v AC, 50 Hz
standard Power : 24v DC (2 Nos. of 12v,7AhS.M.F Battery)
Zone input : 2 wire loop with 4k7 End of line resistor [EOL]
Standard indication : system on/AC on/Battery on/ Low battery/ charger on/ walk Test/ Auxiliary Trip
operating voltage : 24v Dc
Normal Loop Voltage : 20.4v DC [Approximately]
operating current : 80mA plus 4.2 mA per Zone
open Threshold current : 4.2 mA
short circuit Threshold current : 40 mA
standby Threshold current : 8.2 mA (EOL current + Detectors current)
FEATURES : Fully confirms IS 2189 Modular construction Battery backup with build-in-charging Low battery/battery fail warning audio/visual indication AC fail audio / visual warning Charger fail audio / visual warning Relay output for actuators. Lamp test facility One man Walk Test facility Compatible to all types of conventional detectors Twin RED LED indication for fire Zone isolation facility with loop voltage out off 24 V DC output for External notification devices (sounder, Bell, etc..,) User, Installer & maintenance facility Optional loop sounders Optional Rs 232 communication facility Optional Rs 485 communication facility for remote annunciation panel
TECHNICAL SPECIFICATIONS :
No. of Zones
4 to 64 Zones
Primary power
230V AC, 50 Hz
Standby power
24v DC (2Nos. of 12v, 7Ah S.M.Battery)
Zone input
2 wire loop with 4k7 End of Line Resistor [ EOL ]
Standard indication
System On/Ac/ On/Battery/ Charge On/Walk Test/Auxiliary Trip/Earth fault
FEATURES : Fully confirms IS 2189 Modular construction Battery backup with build-in-charging Low battery/battery fail warning audio/visual indication AC fail audio / visual warning Charger fail audio / visual warning Relay output for actuators. Lamp test facility One man Walk Test facility Compatible to all types of conventional detectors Twin RED LED indication for fire Zone isolation facility with loop voltage out off 24 V DC output for External notification devices (sounder, Bell, etc..,) User, Installer & maintenance facility Optional loop sounders Optional Rs 232 communication facility Optional Rs 485 communication facility for remote annunciation panel
TECHNICAL SPECIFICATIONS :
No. of Zones
4 to 64 Zones
Primary power
230V AC, 50 Hz
Standby power
24v DC (2Nos. of 12v, 7Ah S.M.Battery)
Zone input
2 wire loop with 4k7 End of Line Resistor [ EOL ]
Standard indication
System On/Ac/ On/Battery/ Charge On/Walk Test/Auxiliary Trip/Earth fault
The Euro Series Ionization smoke Detector has a moulded Fire retardant grade plastic case with wind resistant smoke inlets. The smoke detector senses both visible and invisible smoke particles of combustion with early response to fires in the incipient stage.The built in LED flashes every 8 seconds to indicate the healthy function of the Detector.
The Ionization Chamber system is an inner reference chamber contained inside and an outer smoke sensing chamber. These chambers are placed in series, the outer chamber in contact with the atmosphere. When smoke reaches the smoke sensing chamber, the potential at the junction of the chambers change which cause the Detector to change in to the Alarm state. The built in flashing LED goes into the Steady state, Which indicates the Fire Condition.
ADR-3000TM is a state of the art fire alarm control panel. Based on Tele fire's fire com TM technology and using intelligent analog addressable techniques, it monitors and controls input and output devices, offering the very best in capacity, capability and reliability in fire alarm systems. The ADR-3000TM is bridging the gap between conventional fire alarm systems and existing large analog addressable systems, enabling even small fire alarm installations to
benefit from the latest technologies at a very cost-effective price. Furthermore, an ADR-3000TM system can supervise a wide range of smoke, heat and gas detectors, call points, alarm bells, automatic extinguishers, etc., offering an outstanding ability for quick response to dangerous situations.
Features
Modularity
1 to 128 loops, each with 127 addresses;
Flexible capacity
Starting with 127 and up-to 16,256 addresses - in a frame of a multi-unit networked system;
Small Basic Unit
Configurable 1 to 4 loops;
Networking Capability
Linking up-to 32 control panels;
Advanced Activation Matrix (AAM)
Activates any output device according to specific logical manipulation of input devices/zones/control panels;
Alarm Response Time
Less than 1 sec;
PC Control
Devices programming, system control, maps display and maintenance based on Telefire's proprietary software, through a standard RS-232 interface;
Programming Ability
All parameters directly from the front panel (a PC is not a must);
Remote Programming
Software up-date and control (optional);
Protected Access
Protected authorized access through passwords;
Integral Modem
For remote controlling and programming (optional);
Distributed Intelligence
Embedded signal processing in the detector & control panel;
The Euro Series Heat Detector has a moulded Fire retardant grade plastic case with Fire resistant heat inlets. Heat Detector has the two function of Rise Temperature and Fixed Temperature.Heat Detector contains pair of negative Temperature coefficient thermistors. One thermistor is exposed to the surrounding air and responds quickly to changes in air temperature. The other thermistor is insulated from the surrounding air and responds slowly.
When the air temperature increases rapidly, the temperature difference develops between the thermistors. The ratio of the resistance of the thermistors is monitored electronically and a fire alarm is initiated if the ratio exceeds a factory preset level;. This feature illustrates the Rate of Rise function of the Detector. When the air temperature increases slowly, the two thermistors reduced its resistance to a predetermined value, then the fixed resistance will initiate a Fire alarm. This feature illustrate the fixed temperature function of the Detector.
Applications : Fumes from burning alcohol and other clear burning liquids. Suitable for surveillance of premises where fire risks spreading quickly. Applicable whenever the level of ambient smoke, dust or fumes produced by a process may cause unwanted alarms from smoke Detectors.