Oil Field Chemicals Division

 

Since our inception, we are engaged in formulating and supplying a wide assortment of Oil Field Chemicals Divisions, which is widely used in several industries like chemical, petrochemical, pharmaceutical, steel, paper and cement. Formulated using premium grade ingredients, our range meets international quality standards & norms. Further, our team of quality controllers checks the final output on several parameters to ensure quality. Our range includes the following:

 

Oil Field Chemicals Division


Acid Corrosion Inhibitor Grade

Acid Corrosion Inhibitor Grade

Acid Corrosion Inhibitor that we formulate is chemically composed using mixture of organic alophatic. Stable upto 120ºC, our inhibitors are widely used in oil and gas wells to stimulate the flow of oil or gas from the well. Apart from this, our inhibitors are also used for eliminating incrustations in the wells. In addition to this, hydrochloricn acid, which is preferabily high in demand, is forced under high pressure via the hole into the rock formation to make fracture around the hole. For creating such fractures, 10-15 % of hydrochloric acid is used for producing these fractures and to provide complete security to equipment & tools from corrosion. Moreover, our range has pour point of 12.0 ºC (max) and is quality tested for negative presence of arsenic. Our entire range is known for its homogenous, organic liquids and free from visible impurities features.


Physical properties:

Color

Dark Blue.

Odor 

Ammoniacal odor

Specific Gravity

1.06 - 1.08

Solubility

Soluble by forming some haziness in 15% HCl


 
 

Drilling Mud Detergent

Drilling Mud Detergent

 

We are offering our clients Drilling Mud Detergent that finds application in almost all water based drilling fluid systems. It is used for the purpose of reducing the surface tension and it is a powerful wetting agent. This promotes the setting of mud pH and reduces the balling of shale cutting and causes an increase in penetration rate. It is also a good emulsifier & lowers the torque and drag.

 

Some of the specifications are as follows:

  • Physical State : The material is a soapy liquid
  • Density at 25˚C gm./ml. : 1.0 to 1.10
  • Surface Tension 0.25%(v/v) solution of the sample in distilled water at 25˚C dynes/cm : 35.0(max)
  • pH of 1%(v/v) solution of the sample in distilled water : 7.5 to 10.5
  • Emulsion Stability Test : To 485 ml. of distilled water 15 ml. of HSD oil is added slowly.
  • While stirring at medium speed, in Hamilton Beach Mixer 1ml. of the sample is added while stirring and stirring is continued for 5 minutes, after addition is complete. Transfer the contents to 500 ml. measuring cylinder and observe phase separation
  • Immediate separation : shall be nil of HSD oil
  • HSD oil separation after 24 hrs. at room temp. : shall be 5 ml (Max)
  • Mud Lubricity Test : It shall be 0.20 (Max)
  • Foaming Tendency Test : Rise in volume due to foaming : 5% max
  • Dosage : It is advised to use 0.02 to 0.04 U.S. gallons per barrel of mud depending on the properties required
  • Packing: 200 Liters HDPE sea – worthy barrels
  • Handling & Precautions: Liquidet DRS is a slightly alkaline liquid and is safe to handle. However, it is advised to use gloves, aprons and goggles while handling it. If it is spilled on hands accidentally, it is advised to wash it away with cold water

 


 
 

Gas Line Corrosion Inhibitor (H2S)

Gas Line Corrosion Inhibitor (H2S)

p { margin-bottom: 0.21cm; }

Our clients can avail from us, a wide assortment of Gas Line Corrosion Inhibitors (H2S), which is a type of an Oil soluble water dispersible semi-polar organic inhibitor. In this, the organic inhibitor is very effective for sweet carbon dioxide (CO2) or sour (H2S) gas condensate wells, sweet and sour oil wells. In addition to this, our chemical is available in different size of packaging to fulfill the requirements of the clients.

 

Some more information related to the chemical are as follows:

 

  • Physical state:

The material is a free flowing homogenous liquid, which is free from visible impurities and suspended solids

 

  • Compatibility & emulsification tendency:

The material is compatible with untreated crude oil mix, which is prepared by mixing 140 ml of crude oil with 60 ml of AR grade xylene and brine corrodent, shall not form emulsion at 24 ± 2ºC. In addition to this, the interface sludge pad thicknesses will not be more than 5% after 5 hours

 

  • Stability:

The material is heated in a well sealed glass stoppered measuring cylinder at 120 ± 2ºC for 2 hours. In a laboratory oven, neither precipitation nor heterogenous layers are observed, on cooling to ambient temperature and mixing after one hour

 

We conduct various performance tests under dynamic conditions (wheel test) on our range of chemicals:

 

a.) Corrodent Media:

  • It consists of 3.2 % sodium chloride ( LR Grade ) solution in distilled water, having dissolved carbondioxide (CO2) content in the range of 1250 ± 50ppm at 24 ± 2ºC
  • Take 140 ml. untreated crude oil add 60 ml. of AR Xylene to the crude oil
  • 1450 + 50 ppm of Hydrogen Sulphide gas is generated by taking 1gm of sodium sulphide of 35% purity and to this 4ml. of 8.5 - 9 % (W/V) hydrochloric acid is added, so that over all pH of complete corrodant media remains between 3.0 - 4.0
  • Total composition of corrodent shall be 86 ml. of (a) + 10ml. of (b) + 4ml. of 8.5 - 9% HCl + 1gm. Of Na2S of 35 % puriyt. Total volume of test shall be 100ml

 

b.) Metal Coupons:

N -80 steel coupons of sizes 25mm x 25mm x 3 to 4 mm (thickness) approx. and polished to 300 emery grift, free from pits and scratched, (total surface area of all sides taken together shall be 15 ± 1 sq.cm of the coupon)

 

c.) Test Temperature:

50 ± 2ºC

 

d.) Corrosion Inhibitor Dose (W/V) PPM:

200


e.) Exposure Period:

24 hrs

 

f.) Results Required:

  • Inhibitor Efficiency: 80 (Min)
  • Condition of test coupon after test : the test coupons will be free from pits and scratches on visual inspection

 

g.) Dosage:

  • Continuous method: 50 PPM in oil production, which generally do not exceed 250 PPM
  • Small batch for tubing: Mix 8 to 20 liters of CORONIL 35 preferred fluid & batch down the tubing. Frequency of treatment depends upon the severity of problems
  • Dump boiler method: 8 to 20 Liters initial dosing followed by 8 to 20 liters every 2 -3 weeks. Well should be shut for 2 – 3 hrs, after treatment
  • Circulation and park method: Batch 35 -70 liters of product down annulus & circulate around to leave inhibitor in annulus
  • Squeeze method: Average concentration of 100000 PPM per barrel of lease crude or other hydrocarbon solvent
  • Tubing displacement of large batch method 10% coronil 35 to be used

 


 
 

Oil Line Corrosion Inhibitor

Oil Line Corrosion Inhibitor

 

We have gained expertise in providing our clients with a comprehensive range of Oil Line Corrosion Inhibitors, which is formulated using organic specified amines with dispersants. As in almost all oil processing companies corrosion in pipelines, drillings and flowlines is found regularly. For this, we have developed an advanced range of non-corrosive coronil-ol that gives a tough film in the pipeline. In pipelines, if the velocity of flow is less then required for turbulent flow, liquids will not contact top area. For this, in most cases free liquid moves along the bottom of pipe, which depends upon velocity the layer that may be both condensate and water or as discrete layers of oil and water.

 

Specification:
Color 

Light yellow to Dark brown viscous liquid

Specific Gravity

1.00  1.05

Solubility

Soluble in water, sea water & formation water in Proportion.

Toxicity  Low

 

 


 
 

Scale Inhibitoer

Scale Inhibitoer

our clients can avail form us scale inhibitor. Salt content of sea water on an average of 3. 5%. In addition to this, sea water contains about 13 ppm strontium, 65 ppm bromine and trace amount of many. Strontium forms a sparingly soluble compound with sulfate solubility of stantium sulfate in water is 114 mg/lit at the temperature of 25ºc. That is less than calcium sulfate, which is 2630 mg/ht. Expressed as 2h2o, caso4 and more than barium sulfate that has solubility of 2. 3 mg/lit.

 

specifications of scale inhibitor:

1.

physical requirement

will be free flowing liquid at  ambient temperature(18 - 30ºc) free from foreign matter.  

2.

miscibility with sea water

will be completely miscible and compatible with sea water and formation water.

3.

compatibility test 

will pass compatibility test when used in combination with other water flood  chemicals such as polyelectrolytes, defoamers, oxygen scavengers, corrosion  inhibitors and bactericides.

4.

performance test

 
(i)

calcium carbonate scale 

solution a & b (compo-  sitions given below)  containing scaling ions are mixed in presence of   10mg/litre of scaled  inhibitor and placed for   18 hrs. At 65ºc,  percentage scale inhibition should be 98% min.

(ii)

strontium sulphate scale 

when two incompatible solutions a & b (composi- tion given below) containing scaling ions, are  mixed in presence of 10 mg per litre of scale inhibitor,  placed for 18 hrs. At 65 ºc , the percentage scale inhibition  will be 98% (min) for  strontium sulfate incompatible  solutions are :

5. packing

lacquer coated m. S. Drums, capacity 55 gallons each drum.

 

 


 
 

Water Injection Corrosion Inhibitor (WIN)

Water Injection Corrosion Inhibitor (WIN)

p { margin-bottom: 0.21cm; }

We are offering our clients a wide range of Water Injection Corrosion Inhibitors (WIN) that are widely used in oil field for flooding purposes. Generally, oils contain about 3 – 3.2 % water for which sodium chloride is mixed with water that makes it highly corrosive. To prevent this corrosion almost all industries use coronil 505.

 

Some more information about these chemicals is as follows:

 

  • Physical State:

Our chemical are a clear free flowing homogenous liquid at ambient temperature (24 ± 2°C), which is free from foreign matter

 

  • Miscibility with sea water:

Our chemical has viscosity of neat and cab be completely miscible in and compatible with sea and formation water

 

  • Corrosion Inhibitor:

For the excellent working of our chemical, the viscosity of product should not be more than 200 CPS at 300 RPM at ambient temperature 24 ± 1 °C with fan V.G. Meter

 

  • Corrosivity of Neat Product:

Under the open condition, when chemical is exposed for 7 days, our corrosivity of neat product will not be more than 1.0 MPY with API steel material at ambient temperature.

 

Some tests on which our chemicals are check at our premises are as follows:

 

  • Compatibility Test:

Our chemicals pass all the compatibility tests, while tested with other water food chemicals like polyelectrolytes, defoamers, oxygen scavengers, scale inhibitors and bactericides.

 

  • Stability Test:

Stable upto 90 ± 5 °C

 

  • Performance Test:

 

a.) Static Test :

When Sea water containing less than 0.1 PPM dissolved oxygen is treated with 20 mg/liter of corrosion inhibitor, the percentage inhibition should be 80% min at 50°C after 7 days exposure in a system isolated from atmosphere under static condition

 

b.) Dynamic Test :

When Sea water containing less than 0.1 PPM dissolved oxygen is treated with 20mg/liter of corrosion inhibitor the percentage inhibition should be 80% min after 24 hrs. exposure in a system isolated from atmosphere under dynamic test condition (RPM : 24 ± 2)

 

In our chemicals, the exposed coupons (API - 5LX - Gd.B) will be free from pits and scratches on visual inspection in both static and dynamic tests. 

 


 
 

 

Related Product Catalogs

Altret Performance Chemicals Gujarat Private Limited
Manufacturer and supplier of rust prevention chemicals, corrosion inhibitors, fluid corrosion inhibitors, gas corrosion inhibitors, descalent chemicals, cleaning chemicals, marble cleaner, hand wash, dairy cleaner, pharma cleaner and multipurpose cleaner.

View more details

Usha Chemical Company
Supplying and manufacturing rust preventive such as rust prevention chemical, automotive rust prevention chemical, industrial rust preventives, water soluble rust preventives and non flammable rust preventives.

View more details

Chitra Engineering
We are a company of 10 employees, leading supplier and manufacturer of wide range of rust preventive oils.

View more details

Suggested Companies


Related Categories
Search Suppliers
CompanyProductsTrade Leads
OR


IndiaMARTCompaniesProductsTrade LeadsTendersTrade ShowsTravel
© 1996-2012 IndiaMART InterMESH Limited. All rights reserved worldwide.