 Showroom View all our products / services as a slide show. play now
 |
 |
Electrical Equipment
|
Being a reputed manufacturer, supplier and exporter of precision engineering equipment, we offer a variety of electrical & electronic equipment and components that are used in diverse industries. Available in a wide range of options, these precision engineered electrical & electronic equipment and components are supplied as per the national standards and customized as per the requirements of our clients. Our vast range includes:
|
| | Panel We are trusted name in manufacturing all types of electrical panels which are widely used in various industries. Types:
-
- Drawout & non-drawout panel.
- Power factor improvement panel
- Plc control panel.
- Synchronizing panel (lt/ht) 11kv
to 132 kv.
- Starter panel [thyrostor]
- Annunciation panel.
- 11kv to 132kv control& relay panel.
Features: -
- Siplex & duplex pattern.
- Degree of protection :-ip-52 to
ip-65.
- Painting: - powder coating, spray
paint, epoxy paint.
- Compartmentalized design
eliminates risk to maintenance personal.
- Sufficient space for incoming and
outgoing cables.
- Separate busbar and cable
chambers.
- Fabricated with 2/2.5/3mm crca
sheet steel.
- Provided with buzzer & hooter for emergency.
Application
:- They
are widely used in :-
- Control
& monitoring of entire electrical system of a plant / industry.
- Protect
against various electrical faults.
- Better
& smooth trouble free electrical life of various machines.
| | Request for Quotation |
| | Control & Relay Panel Our range of control & relay panel improves power factor to increase energy efficiency. All the specifications and requirements of the clients are taken into account and well complimented. Features
:-
- Siplex
& Duplex pattern.
- Degree
of Protection :-IP-52 to IP-65.
- Electromechanical
Relay / Numerical Relay.
- Painting:
- Powder Coating, Spray Paint, Epoxy Paint.
- Compartmentalized
design eliminates risk to maintenance personal.
- Sufficient
space for incoming and outgoing cables.
- Separate
Busbar and Cable chambers.
- Servicing
& maintenance of Relay available.
- Fabricated
with 2/2.5/3mm CRCA sheet steel.
Application
:-
These
are widely used for:
- Protection
and Control for Transformers.
- Protection
and Control for Transmission and distribution lines.
- Protection
and Control for Bus Section and Bus Coupler.
| | Request for Quotation |
| | Control Desk We offer a comprehensive range of control desks completely designed and manufactured by us for all types of Process Control Industries. Features
:-
- Available
in Floor mounting type.
- Degree
of Protection :-IP-52 to IP-65.
- Painting:
- Powder Coating, Spray Paint, Epoxy Paint.
- Compartmentalized
design.
- Designed
to accept 3-phase, 4 wire input volt.
- Provided
with buzzer & hooter during emergency.
- Provided
with 12/24 window annunciator for fault indication.
Application
:- These
are widely used for :-
- Control
& monitoring of various electrical motors, loads etc. of an
electrical system.
- Protect
against various electrical faults.
- Better
& smooth trouble free electrical life of various electrical
machines.
- Control
Desk may save energy of an electrical system.
| | Request for Quotation |
| | Motor Control Centers The motor control center offered to customers is capable to feed larger
loads as it comes with multiple power stabs that support high capacity
industrial motor. Followign are the features & applications of our product: Features
:-
- Simplex
& Duplex pattern.
- Degree
of Protection :-IP-52 to IP-65.
- Painting:
- Powder Coating / Spray Paint / Epoxy Paint.
- Compartmentalized
design eliminates risk to maintenance personal.
- Sufficient
space for incoming and outgoing cables.
- Provided
with buzzer & hooter during emergency.
- Separate
Bus bar and cable chambers.
- Motor
Control Center shall have hinged door with lockable arrangement
- Motor
Control Center shall have detachable gland plates of 2-3mm thick
- Motor
Control Center Available with Aluninium / copper bus bar.
- Fabricated
with 2/2.5/3mm CRCA sheet steel.
- Motor
Control Center is suitable for use on 415V, 3Phase, 4 wire, 50H.z
Application
:- These
are widely used for :-
- Protection
against electrical Short Circuit, overload and earth fault of the
system.
- Control
& monitoring of the entire electrical system of an industry /
plant.
- Systematic
power catering to various load of an electrical system.
- Normally
used in Hospitals, Multi-storied buildings, steel industries, cement
industry, open –cast mines, shopping mall etc.
| | Request for Quotation |
| | Power Control Center We manufacture power control centres which can design as per the requirement of the client at most competitive prices. Features
:-
- Simplex
& Duplex pattern.
- Degree
of Protection :-IP-52 to IP-65.
- Painting:
- Powder Coating, Spray Paint, Epoxy Paint.
- Compartmentalized
design eliminates risk to maintenance personal.
- Sufficient
space for incoming and outgoing cables.
- Separate
Busbar and Cable chambers.
- Fabricated
with 2/2.5/3mm CRCA sheet steel.
- Panel
shall have hinged door with lockable arrangement
- Power
Control Center shall have detachable gland plates of 2/3 mm thick.
- Power
Control Center is suitable for use on 415V, 3Phase, 4 wire, 50Hz.
- Provided
with buzzer & hotter for emergency.
Application
:- These
are widely used for :-
- Protection
against electrical Short Circuit, overload and earth fault of the
system.
- Control
& monitoring of the entire electrical system of an industry /
plant.
- Systematic
power catering to various load of an electrical system.
- Normally
used in Hospitals, Multi-storied buildings, steel industries, cement
industry, open –cast mines, shopping mall etc.
| | Request for Quotation |
| | Power Distribution Board We manufacture power distribution boards that not only save installation costs but also cost of equipment storage, handling and field testing. Following are the features & application of our product: Features
:-
- Degree
of Protection :-IP-52 to IP-65.
- Painting:
- Powder Coating / Spray Paint / Epoxy Paint.
- Compartmentalized
design eliminates risk to maintenance personal.
- Sufficient
space for incoming and outgoing cables.
- Provided
with buzzer & hooter during emergency.
- Separate
Bus bar and cable chambers.
- Power
Distribution Board shall have hinged door with lockable arrangement
- Available
with Aluninium / copper bus bar.
- Fabricated
with 2/2.5/3mm CRCA sheet steel.
- Power
Distribution Board is suitable for use on 415V, 3Phase, 4 wire,
50Hz, AC supply system.
- Available
in Cubicle and Pedestal type.
Application
:- These
are widely used for :-
- Protection
against electrical Short Circuit, overload and earth fault of the
system.
- Control
& monitoring of the entire electrical system of an industry /
plant.
- Systematic
power catering to various load of an electrical system.
- Normally
used in Hospitals, Multi-storied buildings, steel industries, cement
industry, open –cast mines, shopping mall etc.
| | Request for Quotation |
| | Junction Box We offer to our clients a wide range of junction boxes that are
manufactured in a variety of metal boxes and non-metallic combinations.
Our product features & application include: Features
:-
- Available
in Floor Mounting & Wall Mounting.
- Degree
of Protection :-IP-52 to IP-65.
- Painting:
- Powder Coating / Spray Paint / Epoxy Paint.
- Junction
Box shall have hinged door with lockable arrangement
- Available
with Aluninium / copper bus bar.
- Fabricated
with 2/2.5/3mm CRCA sheet steel.
Application
:- These
are widely used for :-
- Joining
/ Connection of various electrical wires coming from field and panel
side.
- Junction
Box ensures connectivity of electrical & electronics of a
system.
| | Request for Quotation |
| | Battery Charger Battery Chargers are used to charge rechargeable batteries time and
again. These batteries are available at various current
levels. Designed and fabricated with precision, our battery
chargers provide a constant voltage and current to charge batteries. Features
:-
- Accurate
float charge to eliminate the possibility of batteries getting
overcharged.
- A
Change over contactor of emergency lighting and an under voltage
alarm is provided in the charger unit.
- Step
less control for charging is being provided to ensure quick charging
of batteries if discharged during emergency.
- Indication
lamp LED type for mains on charging on float/trickle/boost with
Voltmeter and Ammeter provided to indicate charging voltage and
current.
- Degree
of Protection :-IP-52 to IP-65.
- Painting:
- Powder Coating, Spray Paint, Epoxy Paint.
- Compartmentalized
design eliminates risk to maintenance personal.
- Rubber
mat provided for protection against acid spillage.
- The
sealed construction, incorporation of the filter float plug ensures
that the atmosphere is absolutely acid free.
Types
:-
- Float
cum boost battery charger.
- Float
cum boost with Trickle battery charger.
- Manually
operated battery charger with multiple voltage & current.
Applications
:
- To
charging a battery, specially dry cell unit and to ensure accurate
voltage of an electrical system.
- Uninterrupted
working of machines & equipments.
| | Request for Quotation |
| | CT & PT Current Transformers
A current transformer (CT) is a type of instrument transformer designed to provide a current in its secondary winding proportional to the alternating current flowing in its primary. They are commonly used in metering and protective relaying in the electrical power industry where they facilitate the safe measurement of large currents, often in the presence of high voltages. The current transformer safely isolates measurement and control circuitry from the high voltages typically present on the circuit being measured. Current transformers are used extensively for measuring current and monitoring the operation of the power grid. The CT is typically described by its current ratio from primary to secondary. Often, multiple CTs are installed as a "stack" for various uses (for example, protection devices and revenue metering may use separate CTs). Similarly potential transformers are used for measuring voltage and monitoring the operation of the power grid.
The accuracy of a CT is directly related to a number of factors including:
- Burden
- Burden Class /Saturation Class
- Rating factor
- Load
- External electromagnetic fields temperature and
- Physical configuration.
Potential Transformers
Protective Current Transformers are designed to measure the actual currents in power systems and to produce proportional currents in their secondary windings that are isolated from the main power circuit. These replica currents are used as inputs to protective relays which will automatically isolate part of a power circuit In the event of an abnormal or fault condition therein, yet permit other parts of the plant to continue in operation. Satisfactory operation of protective relays can depend on accurate representation of currents ranging from small leakage currents to very high over currents, requiring the protective current transformer to be linear, and therefore below magnetic saturation at values up to perhaps 30 times full load current. This wide operating range means that protective current transformers require to be constructed with larger cross-sections resulting in heavier cores than equivalent current transformers used for measuring duties only. For space and economy reasons, equipment designers should however avoid over specifying protective current transformers ITL technical staff are always prepared to assist in specifying protective CT's but require some or all of the following information:-
- Protected equipment and type of protection.
- Maximum fault level for stability.
- Sensitivity required.
- Type of relay and likely setting.
- Pilot wire resistance, or length of run and pilot wire used.
- Primary conductor diameter or bus bar dimensions System voltage level.
| | Request for Quotation |
| | Insulators Our company has all the facilities to manufacture quality electrical insulators with high mechanical strength and outstanding electrical properties. Types:
- Disc
Insulators Antifog 45 KN B&S, 45 KN T& C.
- LT
GUY Insulators
- Pin
Insulators.
- Post
Insulator.
- Barrel
Insulators.
Features
:-
- Highly
popular for their capability to bear voltage fluctuations.
- Combined
Eletro Mech. Strength 45KN to 90KN.
Application
:- They
are widely used in :-
- Low
Tension Electrical Distribution Power lines.
- Low
Tension Electrical service connection power lines.
- Barrel
Insulators are also used in Construction of Electrical Panel Board.
- Insulators
are used to protect electrical hazards.
| | Request for Quotation |
| | Drum Controller & Master Controller Air break drum controllers are manufactured in accordance with customer specification. They are suitable for controlling A.C & D.C motors used in E.O.T cranes, haulages in mines, winches, steel works. Mainly three sizes are manufactured, 40 Amps, 60 Amps, 150 Amps. Provided with stator reversing contacts. A star wheel and roller arm give definite step location. The crank type-operating handle is provided with off position trigger to prevent accidental starting or unwanted reversing. Operating handle is provided with deadman handle if required by the client Auxiliary contacts are provided for Electrical inter locking. Arc Shields:Arc shields are provided on both D.C and A.C. type controllers. Cable Entry:Standard cable entry is through a base plate, other type of fittings, can also be provided as per clients desire. Construction:Robust construction, top & bottom made of M.S. Plate. The fingertips are made of Hard drawn copper, grinding finish. Removable front cover made of sheet steel. Drum: The contact segments are of Hard drawn Electrolytic copper, turned after assembly to maintain concentricity. The contact assembly of controllers fixed on to insulated M.S. Shaft.
Concepts in switching technology with miniaturization & sophistication for used in automatic control circuit like master control switch where mechanical positions is translated into electrical signals for controlling remote starters, contactors and work in highly contaminated atmosphere and extremely high shock and vibrating condition. Every Limit Switch goes under rigorous testing before it is supplied. A wide variety to afford a high degree of versatility is available. The range includes:-
-
Grab differential limit switch.
-
Spindle type rotary geared limit switch.
-
Heavy duty lever type limit switch.
-
Roller lever.
-
Counter weight.
-
Forked lever.
-
V-shaped lever.
-
Double Roller lever
-
Foot Pedal
-
Heavy duty cam operated Rotary Geared Limit Switch.
-
Push rod limit switch.
-
Heavy duty pull cord switch.
-
Explosion proof limit switch for Hazardous atmosphere.
-
Heavy duty snap action limit switch.
Technical Specification & Features
-
Utilisation category: AC 11 & DC 11 as per IEC IS 6875.
-
Thermal current 10 amp to 40 amps.
-
Insulation voltage 600 V AC & 240 DC.
-
Operating temperature – 20ºC to 110ºC.
-
Mechanical life – 20 million cycle.
-
Contact life: 10 million cycles.
-
Terminal capacity: 2.5 mm2.
-
Operating Torques: 6.804 to 14.968 KLS depending on switch size and cam selected.
-
Enclosure: IP 67
-
Characteristics
-
Oil tight, Water tight & Dust proof.
-
Time tested, extremely reliable design
| | Request for Quotation |
| | Resistance Box
We are engaged in manufacturing grid resistance boxes of motor and crane control resistors, load banks, resistance banks, neutral grounding cubicles / resistors and a variety of custom built power electrical resistors and associated control panels.
Stainless steel grid resistances are highly recommended for use on crane and other machines due to its high mechanical, loss temperature co-efficient of resistance, high resistively, easy adjustability, requirement of less space, long life etc.
Resistance Boxes
Our range of resistance boxes & starting resistors are used for both AC and DC applications. It is widely used for controlling and developing higher torque and have extensively applicable in:
-
E.O.T Cranes
-
Rolling Mills
-
Steel Plants
-
Flour Mills
-
Cement Plants
-
Power Plants
-
Coil Mines
The grids of our starting resistors are made from stainless steel and punched steel sheet and are suitable for maximum temperature rise of 375 degree C as per BSS standards.
| | Request for Quotation |
|
 |