These CADEL MAKE DIGITAL ENERGY METERS are used for sub metering at lower levels in the distribution system. Due to its numerous features these are widely applicable in energy management and various other industries.
|
Power & Power Factor Meters Digital Load Managers, Energy,POWER & POWER FACTOR METERS - Crisp, bright 3 row, 12.5 mm LED displays
- A single 3 Element Meter caters to 3 Wire / 4 Wire measurement
- Automatic scaling of display optimises readings
- Auto Scroll / Hold facility in multi-parameter models
- Cumulative Data retention for indefinite period in the absence of
- auxiliary supply
- Automatic correction of reverse power flow for Energy computation
- All editing functions are password protected
- Unique service support
- Over-the-counter free replacement within warranty
- Reduced rate replacement outside warranty (Optional)
|
 |
Send Enquiry Frequency Meters - AC & DC Digital Voltage, Current, Frequency Meters - AC & DC - Field Settable Full Scale including Decimal Point placement
- Built-in Auto Scroll / Hold facility in 3 phase models
- Wide Auxiliary Supply Range : 85 - 270 V AC or DC
- Crisp, bright, 12.5 mm LED display
- Slide and Lock mounting clamp makes panel mounting simple and
- quick
- Unique service support
- Over-the-counter free replacement within warranty
- Reduced rate replacement outside warranty (Optional)
|
 |
Send Enquiry


DIGITAL DEMAND ANALYZERS, Incoming Managers & Generator Monitors User selectable Billing Cycle facility to synchronize with EB billing cycle (Auto & Manual billing cycle modes) - Synchronous recording of Maximum Demand with date and time of occurrence,
- Average PF and Energy Consumption for previous billing cycle
- Demand Utilization Index (DUI) synchronized to billing cycle provides value info!
- Low battery warning ensures safe use of the product in a critical application
- User selectable demand integration parameter (W or VA)
- Demand data retention during demand interval even if auxiliary supply fails
- Built-in Relay Output ensures facility to trip on Target Demand being reached
- Upto 2 additional independently programmable 10 A Relay Outputs provide
- advance annunciation based on Minutes to Trip or % of Target Demand reached
- Unique freely user settable % of Target Demand provision for external relays
- Display of Current Demand, Elapsed Minutes, Minutes-to-trip and Excess /
- Spare Load allows correct & timely user action optionally for demand control
- 9 digit Energy reading practically eliminates roll-over of reading
- User selectable display grouping (Electrical / Demand / All parameters)
- Automatic scaling for Kilo and Mega units with automatic decimal placement
|
 |

Send Enquiry Digital Demand Controller


DIGITAL DEMAND CONTROLLER - Energy Monitoring System (EMS) - CD 781
The CD 765 and CD 675 are state-of-the art Digital Electrical Demand Analyzers.Housed in a 96 x 96 mm bezel size casing, these are the smallest and mostadvanced such products in the market today and offer many first time features like: · User synchronized Billing cycle.· Displays Current Demand, Elapsed Minutes, Minutes to Trip, Excess /Spare Load, Maximum Demand & Target Demand. Informs when TargetDemand is likely to be exceeded & how much load is to be shed to avoid this.· Demand Utilization Index (DUI) .· Power Supply Interruption recording.· Intelligent parameter display grouping.· Predictive demand monitoring.· Old Maximum Demand, Average PF & Energy Consumption.· Last three relay trip records with relay identification & trip time. These advanced features deliver not just demand control but also empower usersto systematically move towards objective management of Electrical Demand.
The value of these products is superbly enhanced by the graphical software“CADEL DEMAND VIEW PLUS (CS D01)” that displays all the information in theDemand Analyzer plus running demand curve (another first time feature) in a singlescreen on a standard desktop PC. Combined with user-centric features like simpleproduct configuration, clear display of electrical and demand parameters, reducedkeyboard, automatic resolution selection, etc., these products deliver exceptionallyhigh value for users interested in electrical demand management rather than meredemand control. |
 |

Send Enquiry


DIGITAL LOAD MANAGER, Energy, Power &Power Factor Meters | Digital Energy, Power and Power Factor Meters | | Model Number | Parameters | | CD 613 CD 617 CD 619 | WH (includes VAH & APF) W PF | | CD 603 CD 605 CD 607 CD 609 CD 611 | V, I, W, VA, VAR, PF, WH I, W, VA, VAR, PF, APF, WH, VARH I, W, VA, VAR, PF, APF, WH, VAH V, I, W, VA, PF, APF, WH V, I, W, VAR, PF, APF, WH | | CD 667 | I, W, VA, VAR, PF, WH | | CD 651 CD 653 CD 657 CD 641 CD 631 | V, I, Hz, W, WH V, I, Hz, W, PF W, VA, VAR, PF, WH V, I, Hz, W W, VA, PF | | CD 625 | I, WH | | Technical Specifications | | Configuration | 3 Phase, 3Element, 3/4Wire | | Input Voltage | User selectable from Rear Panel | | Nominal | 415V LT or 110V through PT (line to line) | | Range | 80% to 120% of Nominal | | Input Current | Factory Set | | Nominal | 5A or 1A through CT | | Range | 1% to 120% of Nominal | | Input PF Range | 0.5 Lag to Unity to 0.5Lead | | Computation | True RMS for all power & energy Parameters | | ACCURACY | ± (0.5% of FS + 0.5% of Rdg + 1digit) ± 0.2% for Frequency ± 1.0% for FS for Current | | DISPLAY | 3 simulataneous display for 3 digit, 12.5mm, 7 segment, super-bright LEDs | | Isolation | 2000V AC for one minute | | SAFETY | Measurement Category III Pollution Degree 2 as per EN1010-1 First Edition | |
 |

Send Enquiry


Digital Voltage, Current, Frequency Meters - Field Settable Full scale including Decimal Point placement
- Built-in Auto Scroll/Hold facility in 3phase models
- Wide Auxiliary Supply Range : 85-270V AC or DC
- Crisp, bright 12.5mm LED display
- Slide and Lock mounting clamp makes panel mounting simple and quick
- Unique service support
- Over the counter free replacement within warranty
- Reduced rate replacement outside warranty (Optional)
| Input | As per Product Selection Chart overleaf | | Computation | Average Sensing | | ACCURACY | ± (0.5% of FS+0.5% of Reading) + 1digit) ±0.2% for Frequency ±1% of FS for current | | Resolution |
| | Volts | 1 Volt | | Kvolts/Amps | Field settable through Full Scale and Decimal Point Modules | | FREQUENCY | 0.1Hz | | DISPLAY | 12.5mm,7segment, super-bright LEDs | | Aux Supply | 85-100V AC or DC/150-270V DC or Dc for Cd 221 and CD 223 | | Isolation | 2000 V AC for one minute | | SAFETY | Measurement category III, Pollution Degree 2 as per EN61010-1 First Edition | | BURDEN | 0.1VA typical per Voltage/Current input CD221/CD223: 2VA typical on Aux. Supply | | Ambient | Temp 0-50°C, Humidity<95% non-condensing | | Weight | CD221/CD223: 400-450gms, model dependent other models: 170-210gms, model dependent | | Dimensions | CD221/CD223: 96x96mm (Bezel) x91mm Other models : 96x48mm (Bezel)x76mm | | Panel Cutout | CD221/CD223: (90(mm x (90)mm Other models : (90) mm x (44) mm | | Mounting | Slide and Lock clamp | | Warranty | 15 months from date of manufacture OR 12 months from date of sale, whichever is earliet | |
 |

Send Enquiry Digital Voltage, AMP, HZ Meters


Digital Voltage, Current, Frequency Meters AC & DC - Field Settable Full scale including Decimal Point placement
- Built-in Auto Scroll/Hold facility in 3phase models
- Wide Auxiliary Supply Range : 85-270V AC or DC
- Crisp, bright 12.5mm LED display
- Slide and Lock mounting clamp makes panel mounting simple and quick
- Unique service support
- Over the counter free replacement within warranty
| Input | As per Product Selection Chart overleaf | | Computation | Average Sensing | | ACCURACY | ± (0.5% of FS+0.5% of Reading) + 1digit) ±0.2% for Frequency ±1% of FS for current | | Resolution |
| | Volts | 1 Volt | | Kvolts/Amps | Field settable through Full Scale and Decimal Point Modules | | FREQUENCY | 0.1Hz | | DISPLAY | 12.5mm,7segment, super-bright LEDs | | Aux Supply | 85-100V AC or DC/150-270V DC or Dc for Cd 221 and CD 223 | | Isolation | 2000 V AC for one minute | | SAFETY | Measurement category III, Pollution Degree 2 as per EN61010-1 First Edition | | BURDEN | 0.1VA typical per Voltage/Current input CD221/CD223: 2VA typical on Aux. Supply | | Ambient | Temp 0-50°C, Humidity<95% non-condensing | | Weight | CD221/CD223: 400-450gms, model dependent other models: 170-210gms, model dependent | | Dimensions | CD221/CD223: 96x96mm (Bezel) x91mm Other models : 96x48mm (Bezel)x76mm | | Panel Cutout | CD221/CD223: (90(mm x (90)mm Other models : (90) mm x (44) mm | | Mounting | Slide and Lock clamp | | Warranty | 15 months from date of manufacture OR 12 months from date of sale, whichever is earliet | |
 |

Send Enquiry
|