1
Have a requirement?
Chat with us
1
Have a requirement?
Chat with us
Water Management Devices
FEATURES
Saves Electricity & Water wastage.
24hrs uninterrupted water supply.
No deposition on level sensors for life time.
No more dry running & burnouts of pumps.
5 year guarantee.
Interested in this product?
Get Best Quote
Usage/Application | Dewatering System |
Voltage | 12 V DC |
Brand | Electronic Guard |
Maximum Fluid Temperature | 45 Degree C |
Maximum Flow Rate | 30 L/min |
Maximum Output Pressure | 0.55 bar |
Auto Booster Pump Controller cum Level Indicator
Model-AB Premier
- 3 level indication (high, med ,low) of overhead and underground / sump tank.
- Alram gets On when water goes below low level in Sump or Overhead Tank
Description
This model automatically switches on the pump when water is the overhead tank goes below the ½ level and switches OFF the pump when water reaches the full level. The pump gets ON only if the water in the sump tank is above height ¼th level and the pump would go off if the water in the sump tank goes below the low level of the tank. ODD start push button is available for starting the pump at any stage but pump would switch OFF automatically.
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Brand | Electronic Guard |
Type | Digital |
Material | ms |
Packaging Type | box |
Number Of Pieces Per Packet | 1 |
Phase | 3 |
I Deal In | New Only |
Drain Tank Models
Model-LC 21
• 2 level indication of the tank (high & low).
Model - LC 51
• 5 level indication of the tank
• Selectable pump start level with the help of selector switch.
Description
This unit automatically switches ON the pump when the water level reaches the high / starts level of the tank and switches OFF the pump when water goes below the low level of the tank.
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Model-LS
Description
This model senses the water in the main line and switches ON the pump as water supply comes in the line. When water supply goes off, the pump stays ON for the ‘OFF time delay’ (20 seconds) period, if water supply comes back before the completion of 'OFF time delay', then the pump continues to stay ON and timer gets reset. Once OFF time delay is complete then the pump gets ON only after rest time of 20 seconds to avoid frequent switching.
Description
This model senses the water in the main line and switches ON the pump as water supply comes in the line. When water supply goes off, the pump stays ON for the ‘OFF time delay’ (20 seconds) period, if water supply comes back before the completion of 'OFF time delay', then the pump continues to stay ON and timer gets reset. Once OFF time delay is complete then the pump gets ON only after rest time of 20 seconds to avoid frequent switching.
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Brand | Electronic Guard |
Type | Digital |
Material | MS |
Size | Compact |
Packaging Type | Box |
Number Of Pieces Per Packet | 1 |
I Deal In | New Only |
Fill Tank Models
Model - LC 22
• 2 level indication of the tank (high & low).
Model - LC 52
• 5 level indication of the tank
• Selectable pump starts level with the help of selector switch.
Description
This unit automatically switches on the pump when the water level goes below the start level (low level) and switches off the pump when the water level reaches the full level (high level) of the tank.
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Level Indicator
Model - LI
Indicates five different water levels in the tank i.e. low, 1/4th , 1/2 th, 3/4 th and Full. Alarm gets On when water goes above "Full" level or goes below "Low" level of the tank. Push Button is provided on top of the unit to switch off the Alarm.
Model - LI
Indicates five different water levels in the tank i.e. low, 1/4th , 1/2 th, 3/4 th and Full. Alarm gets On when water goes above "Full" level or goes below "Low" level of the tank. Push Button is provided on top of the unit to switch off the Alarm.
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Function Description
This unit is to control the boiler operation. The heater gets on when water touches the "Low" level of the boiler. The pump gets ON when when water goes below the pump start level, after the set on time delay, adjustable with the help of a linearly caliberated knob, provided on top of the unit. The Pump gets "OFF" when water touches the Pump Stop (Top) level of the boiler.
Dimensions
This unit is to control the boiler operation. The heater gets on when water touches the "Low" level of the boiler. The pump gets ON when when water goes below the pump start level, after the set on time delay, adjustable with the help of a linearly caliberated knob, provided on top of the unit. The Pump gets "OFF" when water touches the Pump Stop (Top) level of the boiler.
Dimensions
Height 105 mm, Width 51mm, Length 102mm
Burden
Voltage Supply : 5 VA (Max.) Current Supply : 1 VA (Max.)
|
Additional Information:
- Item Code: BC-22
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Features:
For more details please refer the pdf. file:
- Saves Electricity & Water wastage.
- 24hrs uninterrupted water supply.
- No deposition on level sensors for life time.
- No more dry running & burnouts of pumps.
- 5 year guarantee.
For more details please refer the pdf. file:
View Complete Details
Yes, I am interested!
Tell us what you need, and we’ll help you get quotes
Tell us what you
need
need
Receive seller
details
details
Seal the deal
Pay with IndiaMART