|
Audio Communication Equipment
Engaged in manufacturing and supplying of industrial process instrumentation and audio communication systems. Detailed of our product range is given below:-
|
  | Public Addressing System Public address system and conference systems with power amplifiers, speakers, microphones (wired and wireless), mixing consoles, signal processors and other accessories are chosen to provide sound reinforcement for various applications. We, at Elixir Electronics design and develop the sound reinforcement system for installation in commercial complexes, schools, conference halls, auditorium, sports stadium, places of worship, etc.
1a. Professional Audio Products: We offer designing of sound equipments products for professional applications such as for auditoria, stadium and commercial complexes.
1b. Multi Channel Background Music Selector System: System elements comprising of channel selector modules are available for use in multi channel music system, language selection system, etc. The other audio system elements includes amplifiers, signal processors, microphones, speakers , etc, that can be supplied to make a complete system. 1c. Custom Built Audio Systems: We have the expertise to design and supply custom built audio systems and professional audio racks complying our customer specifications and requirements.
Request for full product details and quotation |  
  | Industrial Paging System Elixir Electronics manufactures and supplies a wide range of industrial PA and communication Systems. 2a. Industrial Paging & Talk Back System PPT9000 HS – Wall mounting type handset station- provided with a noise cancelling type handset for full duplex communication; audio page output power – 15 W rms. PPT9000 PP – Wall mounting type pilfer proof station – provided with an inbuilt mic and speaker, suitable for simplex communication; audio page output power – 15 W rms. PPT9000 DS – Indoor typed desktop handset station – with a desktop unit for indoor usage. Connected with extension amplifier model – PPT9000 EA, the rated audio page output power is 6 W rms. All the systems can be hooked up with existing EPABX system for one way communication. All the units have provision to operate on 110 VAC / 230 VAC / 24 VDC Supplies. Features: - Alert tone
- Page power 15 W rms.
- Frequency response 200 Hz – 10 kHz
- THD better than 1%.
- Enclosure LM6 aluminium alloy
- Power supply AC mains / 24 VDC
Technical Specification: | MICROPHONE: | | | Type | Dynamic, Noise Canceling | | Internal Impedance | 300 O @ 1 Khz | | Sensitivity | -56 dB @ 1 KHz relative to 1V/Pa | | RECEIVER | | | Type | Dynamic | | Internal Impedance | 300 O @ 1 Khz | | S.P.L. | 108 dB @ 1 Khz | | LINE AMPLIFIER SECTION | | | Input Sensitivity | 1 mV to 5 mV (adjustable) | | Input Impedance | 4.7 K (resistive) | | Load Impedance | 250 O, Balanced (Resistive) | | Output | 2V RMS, 10 MW | | Distortion | < 1% @ 1 Khz | | Residual Noise Level | - 50 dB | | Frequency Response | 200 Hz - 10 Hz, /- 3 dB | | Gong tone Frequency | 600 Hz /- 100 Hz | | Gong tone Duration | 1.5 Secs (app.) | | POWER AMPLIFIER SECTION: | | | Input Sensitivity | 770 mV RMS @ 1 Khz | | Input Impedance | 250 O (Resistive) | | Distortion | < 1% @ 1 Khz | | Residual Noise Level | - 60 dB | | Frequency Response | 200 Hz – 10 kHz, /- 3 db | | Output Power | 15 w RMS @ 1 kHz | | | 11 v @ 8 O &16 V @ 16 O | | Protection | Short Circuit, Open Circuit, Overload & Oscillations. | | POWER SUPPLY | | | Supply voltage | 240 V AC (or) 110 V AC, 50 Hz /- | | | 10% or 24 v dc | | Power Consumption | 35 VA | MECHANICAL SPECIFICATIONS | Enclosure | LM6 Aluminum Alloy | | Finish | Light Grey, Shade 631 of IS5 | | Dimensions | 280 mm (h) x 230 mm (w) x 110 mm | | Weight | 7.6 kg (app.) | | Cable Entry | 19 mm Dia, 3 Nos. Cable glands | | Mounting Arrangement | Vertical | Request for full product details and quotation |  
  | Eight Channel Partyline System Elixir make 19” rack mountable intercom system provides 8 party channels 1 page channel to operate in the simplex mode. The party channels are selectable by mechanically inter locked latching type switches. The common page channel is always available in receive mode irrespective of the voice channel selected. AGC circuitry provided for even output. The intercom unit is modular in construction and all modules are replaceable from front panel for easy maintenance. The unit has an elegant anodized front panel and neatly engraved for all controls. It is closed from all sides to reduce entry of dust and suitable provision is made for ventilation to dissipate internal heat. The unit is designed to with stand the operating temp range up to 50 ºC. Automatic gain control unit (AGC) provides a constant output of 250mV – 500mVpp, which can be adjustable with internal threshold level preset provided internally). Output power of the external page amplifier (receive) is 6W RMS @ 8Ω resistive load. Unit can be set to operate on 30 VAC / 110 VAC / 24VDC. These settings can be carried out by authorized personnel only. Front Panel: - Gain control
- 3 Nos. of 5pin socket
- Mechanically interlocked latching type selector switches
- Page channel selection switch
- Built in speaker to monitor channel conversation
- Mute switch for the monitor speaker
Rear panel: - Signal line connector
- Recording Output
- Operation on AC mains / external DC
Accessories: - Power cord with connector – 1 No.
- Mating connectors – 5 Pin 240 º. Metal lockable male connector – 3 Nos.
- 25 Pin ‘D’ type male mating connector with 5 mtrs. Length of 10 pair flexible cable – 1 No.
- Page loud speaker output connector – 1 No.
- Operating and service manual containing complete block and wiring diagrams, circuit diagrams of each module with component layouts and detailed list of components
Request for full product details and quotation |  
  | Operator Console System Elixir make micro controller based oerator console system consists of a phone type operator console and a micro controller operating unit. It is intended for use in industrial public address system wherever the field paging stations are connected to the operator for passing on instructions during the process of manufacture. The system includes two sets of operator consoles with the required relay units. Each operator console has a dedicated group of field stations from where the operator is often consulted for suitable instructions during the process. In addition, there is a group of field stations which are common to both the operators in the sense that this group of field stations require to contact both the operators for instructions and vice versa. Each operator system consists of a relay unit accommodated in a 19” sub rack; a power supply unit and a desk mounted telephone type operator console also known as Master Console Desk (MCD). The master control desk (MCD) is normally connected to the relay unit of the system through 8 core and 7core cables. The master control desk is powered with 5volt supply from the relay unit. The balance 6 core is used to carry Logic to HS, logic to E3, 24V for relay operation in MCD, Analog Ground, and Rxd Txd for data. The relay unit has two channels page and private. When a call is made between master control desk & any of the stations, both the channels get connected. Normally the operator can speak on page line using ‘Page’ key or can converse on private channel with duplex facility.
Features: Selective call, conference call, group call, all call, emergency siren, can communicate with the stations in different groups, automatic date and time updating facility, standby mode operation, compact and easy to handle, alert tone, to accommodate 20/40 field stations with display of calling station id.
Request for full product details and quotation |  
  | Train Announcement System Elixir make DGPAS provides the audio inter communication between driver and guard and announcement to passenger by driver/guard. The system consists of amplifier, console with switch panel, microphone, ceiling speakers switch panel and microphone are the parts of console. The console and amplifier are connected to the ceiling speaker (4 watts rms) in the trailer and motor coaches. Console is the central unit of the system which connects the switch panel, microphone, amplifier and speakers. Public Mode: Announcement from either driver or guard to passengers shall function on first come first serve basis. Private Mode: Communication between driver and guard can be initiated by either one of them. Driver or guard should press the push button in switch panel; a chime tone is heard in the other cabin attracting his attention. The other person presses the microphone switch and the private mode switch simultaneously to converse. Music Mode: The music mode has the least priority and can be played by the driver or guard. If not required, it can be reset. Features: - Zone indicator
- Local/Remote
- Volume control
- Music reset
- Three priority level
- Priority 1: Private Mode – Communication between driver & guard or vice versa;
- Priority 2: Public Mode – announcement by driver or guard to the Public;
- Priority 3: Music Mode – can be played either by the driver or guard. When the system is in music mode of operation, the public mode will override the music. When a call is initiated by driver / guard in the private mode, this will override the public mode in operation.
Request for full product details and quotation |  
  | Emergency Evacuation System The automatic emergency evacuation announcement system provides emergency mass notification and evacuation. With its modular construction, the system is a highly versatile stand-alone product. It is easy to install, and the system is a network of voice transmission with emergency siren. The system provided with a facility for remote activation of emergency evacuation announcement; includes a 100 W rms amplifier unit. It can operate even during Failure of mains power. An emergency evacuation system to meet specific needs with additional features can be designed and supplied.
Request for full product details and quotation |  
  | Public Safety Announcement System Item Code: Megaphone Waistband megaphone is provided with an inbuilt voice recorder circuitry to record and play safety announcements specially by mobile personnel on railway platforms. The maximum duration of recording and playback of voice message is limited to 8 minutes. Facility for Repeat play of message provided. Audio output of 5 W is available through the built in speaker. Features: - Available with Tie - Clip condenser gooseneck microphone
- Operates on 6 Nos. Ni Cd rechargeable batteries.
- Built in battery charging facility for rechargeable cells
- Can also recharge by AC adapter
Request for full product details and quotation |  
  | 2 - 4 Wire Audio Interface Unit Elixir make audio interface unit ECS503 is used to interface bi-directional voice lines to a commercially available standard fiber optic multiplexer system which requires 4 wires inputs. The aim of the configuration is to interface 2 wire high signal low impedance termination for a 4 wire conversion, and vice versa. The unit feeds 2 wire audio to the 8 channel communication network wired with copper cable medium.
4 Wire Tx: Variable audio signal (2 – 16 Vpp level) is fed to the hybrid circuit of 2 wire voice line of impedance 100 - 300Ω. Half the level of the input signal is obtained at the 4 wire Tx terminals of the hybrid network. This goes through an amplifier stage and an AGC circuit. The AGC output is fed to a mute logic circuit to mute the 4 wire receiver amplifier input so that the leakage of the transmitter output into the receiver circuit is kept to the minimum. 4 Wire Rx: The output of the fibre optic converter is fed to the 4 wire Rx terminals through a coupling transformer. The output of the transformer is fed to the buffer stage and then to an amplifier stage. The output of the amplifier stage is fed to a coupling transformer to the 4 wire Rx of the hybrid network. Additionally the buffered output of 4 Wire Rx is fed to the AGC circuit and the output of AGC circuit is fed to the comparator and this output is used for muting of 4 Wire Tx output when it is present. Specifications: Number of channels to support: 8 (with required slot provision), has dual power supply with 230VAC 10%, 50 Hz input fed from main 1 and main 2. Provision to automatically changeover to 24 DC operation is provided (when an external DC battery is connected). An LED blinker indicates the activity of 4 Wire Tx and Rx port upon selection available. An LED glows when 4 Wire Rx (hybrid) leakage exceeds a set value of 100mvpp. Probe monitoring provision for 4 Wire Rx level is available on the front panel. The interface chassis has one module / channel totaling 8 modules supporting 8 channels. I/P & O/P connections are made through BNC connectors.
Request for full product details and quotation |  
  | PH Meter/Transmitter a. Lab PH Meter Elixir make lab ph meter is a reliable meter to determine the actual ph of sample solution. High input impedance of the circuitry ensures accurate reading. The meter is compatible to all types of ph electrodes with electrical null point at 7.00 ph. Calibration facility for A.P. and slope are provided in the front panel. Special Features: - Measurement of pH and other mV potentials
- Covers 0 – 14 pH / 0 1999 mV.
- 31/2 Digit LED display
- Easy to use and maintain
- Designed for continuous use.
- Accuracy better than 0.01 pH./ 1 mV.
- Auto / Manual Temp. compensation.
b. Online pH Transmitter Elixir make pH Transmitter is an inexpensive, reliable transmitter for converting the output of pH and redox electrode to a standard current signal for measurement and control purposes. High impedance input is provided to pH electrode input. The transmitter is mounted in weather proof enclosure suitable for field mounting. Span and range can be easily set by means of special miniature dip switch on the circuit board. Calibration is simple, using wide range asymmetry and slope correction. Current output from the transmitter is selectable for 0-20mA or 4- 20 mA. Automatic temperature compensation can be applied - 10ºC and 150º C by connecting pt 100 resistance thermometer Special FeaturesMeasurement of pH/ redox, selectable 0- 20 mA or 4- 20 mA output signal, easy installation, maintenance and adjustment, splash- proof enclosure, automatic Temp. Compensation with Pt. 100, accuracy better than 0.01 pH AccessoriesSensor, temperature compensation, indicators & point controllers, electrode holder assembly, extension cables, data acquisition, wireless telemetry. c. Online Conductivity Transmitter Elixir make Online conductivity transmitter is a solid state unit with universal applications. It will provide excellent performance in any conductivity measuring system at low cost. It is easy to install, easy to adjust and requires negligible maintenance. Exceptional stability is achieved with the ICs and other solid state components mounted on the single pc board in a durable, inert, splash-proof case. The unit is suitable for operation at ambient temperature from - 20ºc to 55ºc. Features: Different frequencies for high and low conductivity ranges, temperature compensation with either a reference cell or a NTC transducer. Output: 0- 20 mA or 4- 20 mA, selectable, as required. A comprehensive series of measuring ranges which meet all requirements, including a special range that can be adjusted for any non-standard measurement. Ease of mounting and ready accessibility to selectors and switches ensure simplicity of operation and adjustment. We also supply high accuracy 2 wire process transmitter such as : - Temperature transmitter
- Pressure transmitter
- Differential pressure transmitter
- Flow transmitter
- Level transmitter & accessories
Request for full product details and quotation |  
  | Card Frame & Equipment Rack We supply 19” card frame rack and equipments rack designed and manufactured out of finest raw materials for instrumentation equipments. These are designed by our design engineers catering to meet the demands and expectation of the customers and the industry. The card frame racks comprises of the following offered at competitive prices. These are: - Front profile 84 T
- Rear profile 84 T
- Side frames - 2 U, 3U etc.
- Facia plates - 6 T, 12T, 18T, etc
- Pull out handles and other accessories
Our manufactured equipments rack is suitable for instrumentation and other equipments installed in the control room of an industry. The equipment rack consists of number of slots as per the requirement with a main power supply unit for the whole rack and also provided with separate power supply for each equipment in the rack. Additionally, the rack is provided with acrylic front door, metal rear door, castor wheels, side frames with ventilations, cooling fans and other accessories. Request for full product details and quotation |  
  | Wireless Telemetry Wireless systems for monitoring/ networking of parameter of instrumentation / utilities provide a competitive edge in terms of product quality, capital cost, laying, maintenance and accidental disruption of cable, etc. The wireless system is available in the universal ISM band for most applications. System consist of - Data converter,
- Transmitter and
- Receiver
- Display unit / Annunciation panel
The received data can be displayed and can also be used for subsequent processing. For this system we offer transducer, signal conditioner with wireless transmitter and receiver and display unit. The data acquisition system components such as : - Analog to digital boards
- Digital to analog boards
- Communication boards &
- Accessories
Request for full product details and quotation |  
  
| Design and Consultancy Services We undertake design and consultancy services for audio and instrumentation systems of premium quality. With modern technology, we continue to be the most trusted name in the designing, consultancy, installation and audio system commissioning service provider. Our technically competent team of engineers, technicians and other professionals configure, design, manufacture, supply, install, commission and also provide effective backup service during and beyond guarantee period.
Request for full product details and quotation |  
|
 

|
 |