As it is not possible to use line current directly for measurement and protective relays due to its high value & insulation problem. Current transformers are used to:

  • Reduce the line current to a value (e.g 1 amp.)which is suitable for standards measuring instruments, relays etc.
  • To isolate the measuring instruments, meters, relays etc. from direct line.
  • To protect measuring instruments against short circuit current.

    Principal of operation:-Current transformer works on the principal of variable flux. In the ideal current transformer, the secondary current would be exactly equal to(multiplied by turns ratio) the primary current. But in practice, some of the primary amp-turns are used for magnetizing the core.This causes an error, which is termed as current (ratio)error and phase error.



Summation Current Transformers
Summation Current Transformers
We?manufacture resin cast summation CTs which summates the current in a number of feeders in association with feeder current transformers.'When current flows in more than one feeder is required to be metered summation current transformer are used. These CTs are provided with more than one primary winding and one common secondary. The standard primary & secondary currents are 5 or 1 amp. Summation current transformers are generally manufacture-confirming to ISS 6949.


Specifications:

Primary Current :?5 to 1 A
Secondary Current : 5 or 1
Accuracy Class : 0.2, 0.5,1 A
Burden : 1.25 to 30 VA
Mounting : Threaded inserts for floor mounting.


Send Enquiry


Zero Sequence Current Transformers
We manufacture Core balance or Zero sequence (Tape or Resin Cast ) CTs. These are  for sensitive earth leakage protection and earth fault protection. These are suitable for Bus bar of panels/ bus duct and cables etc.These are ring or rectangular type CTs & suitable for the measurement of the sum of three phase currents in a 3-ph cable. Under normal operating conditions this sum is zero. In the event of an earth-fault the sum of the current is equal to the zero sequence current. It is necessary to specify leakage current to be detected along with minimum setting of the relay and size of cable at the time of ordering CT.

Primary Current :

300 mA to 10 A
Zero Sequence Current Transformers
Send Enquiry



Wound Primary Current Transformers
Wound Primary Current Transformers
We manufacture wound primary CTs (Tape and Resin Cast) designed for large burdens and better accuracies (Metering, Protection and Special protection PS Class). Secondary terminal with threaded insert and primary with brass plated studs suitable for precision measuring test apparatus. Multiratio C.T. available in the portable wooden case to be used as laboratory standard.

Specifications:

Primary Current : 1 to 100A

Secondary Current : 5, 1, 5/rt3, 1/rt3A

Accuracy Class :

For Metering : 0.1 to 1 A
For Protection : 5P, 10P accuracy limit factor 5,10,15,20
For PS Class :    Knee point voltage (VK), secondary resistance
                           and magnetizing current is required.
Burden :             5 to 60 VA

Mounting :          Threaded inserts for floor mounting.



Send Enquiry


Interposing Current Transformers
We manufacture Interposing CTs (Resin Cast ) for matching of ratio with main C.Ts in different protection scheme.

Specifications :

Primary Current
: 5 to 1A
Mounting : Threaded inserts for floor mounting.


Interposing Current Transformers
Send Enquiry



Control Transformers
Control Transformers
We manufacture control transformers that are designed with very low temperature rise and ensure excellent voltage regulation. These also ensure extreme overload capacity of high momentary in-rush current demand by the contractors, relays and solenoids. The output voltage drop under high momentary in-rush current is also very low, which ensures satisfactory operation of contactors, relays and solenoids.

Specifications :

Input Voltage :
  380 V to 415 V
Output Voltage :
110 V to 220 V
Burden : 50 VA to 2500 VA 
Type : Air Cooled
Send Enquiry
{short description of image}




Contact us

Mr. Ajay Mahajan (Manager)
No. 2310, MIE Bank Road
Bahadurgarh, Haryana - 124 507, India

Contact via E-mail

Contact via Mobile

Contact via SMS






Member IndiaMART.com © Eltech Engineers. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry