We offer a wide range of energy saving equipment that are the result of intensive research and have enabled us to come up with a better range of standard and fabricated products. We have a complete knowledge and understanding of the evolving market that assists us in understanding the prevalent trends and requirements. We are supplying as per the specifications of clients and strive to give our best to them. Our products solar water heaters, hydropneumatic systems, power quality analysis, energy audit and power conditioning systems.
 |
|
 |
Electronic Ballast We provide our customers with premium quality Electronic Ballast which gives solution for over voltage problems and also facilitates with auto trip protection and spike protection. Its specifications are as given below:
Features:-
. Up to 40% Energy Saving.
. Wide voltage range 90-300 V AC.
. No EMI/RFI.
. Up to 50% increases tube life.
. Auto trip protection.
. Low current crust factor.
. Safety shut down at faulty lamp
condition.
. Higher power factor-0.98.Less than 10%
total Harmonic distortion (T.H.D)
. Conformation to IS Std 13021 Part I & II
. Over voltage protection.
. Spike protection.
| Model | Lamp Detail | Operating Voltage | AMP | Watt W | P.F. | | Digital | 1*36/40 W | 90-300 V | 145 | 33 | 0.99 | | Ultra | 1*36/40 W | 90-300 V | 145 | 33 | 0.98 | | Plus | 2*36/40 W | 90-300 V | 260 | 56 | 0.98 | | Ultra H.D. | 1*36/40 W | 90-300 V | 145 | 33 | 0.98 |
|  |
 |
|
|
|
 |
 |
Energy Saving Street Light We provide our customers with Energy Saving Street Light/Energy Saving Light which are highly efficient as it saves up to 60% energy. Along with it, it lights instantly and is easily installed and has minimum maintenance cost. Its features are given as under:
. Confirmation to IS 10322 Specifications
. Confirmation to IP-65 Protection
. Higher power factor - 0.98.
. Operating Voltage 90-300 V AC
. Free from Rain, Dust and Insects
. Daylight performance
. Lights weight
. No tripping, Hence wont get off
. Single piece Aluminum body
. Easy install and maintenance
| Model | Lamp Detail | Number of Ballast | AMP mA | Watt W | P.F. | Compare with HPSV/MV* | | USL-3 | 3*36 W | 3 | 390 | 97 | 0.98 | 250 W | | USL IP-3 | 3*36 W | 3 | 390 | 97 | 0.98 | 250 W | | USL IP-4 | 4*36 W | 4 | 555 | 120 | 0.98 | 250 W |
|  |
|
 |
 |
|
|
|
 |
 |
|
 |
Energy Saving High-Bay We offer our customers with high performance oriented Energy Saving High-Bay, which are light weight and easy to handle. Some of its technical features are:
Features
. Up to 60% Energy saving
. Higher power factor - 0.98.
. Operating voltage 90-300 V AC
. Free From Dust and Insect
. Light weight
. Daylight performance
. Low temperature hence useful for AC
Plants
. Lights instantly
. No tripping, Hence won't get off
. Single piece Aluminum body
. Easy install and maintenance
| Model | Lamp Detail | Operating Voltage | AMP mA | P.F. | Watt W | | UHB-4 | 4*36 W PL-L | 90-300 V | 555 | 0.98 | 120 W | | UHB-5 | 5*36 W PL-L | 90-300 V | 675 | 0.98 | 150 W |
|  |
 |
|
|
|
 |
 |
|
 |
Power Quality Analysis We also offer clients our services in the field of conducting quality analysis for ensuring optimum performance of the power equipment, we provide. The power quality analysis helps in analyzing the quantity of electrical power being utilized. It also enables us to know the value of the Voltage and other PQ parameters including the harmonics and the individual harmonic THDs as a percent of the nominal Values. The parameters it includes are:
Electrical System Design Errors.
RMS Voltages, Transient Voltages, Wave shape, Voltage Imbalance, flickers.
Grounding Errors.
Electrical System Design Errors.
Load Interactions.
Harmonics.
Further the job for conducting system harmonic study and analysis allow us to analize online measurement of reactive power & total harmonic distortion at plants input mains and at subsequent important feeders by power quality analysers. It helps us in identifying the quantum of the harmonics with parameters including:
System Voltage RMS.
System Current RMS.
Total Harmonic distortion in voltage & current of system and at individual distribution centres.
In addition to these methodology, we also check the design and structuring aspects of the power conditioning systems and ensure their meeting the prevailing load condition demands of voltage,current, power factor, harmonic levels, and KW.
|  |
 |
|
|
|
 |
|