Miniature Solenoid Valves
Item Code: 2-Way-Miniature-Solenoid-Valves
FLOCON: 2-way midget type and miniature solenoid valves with a compact design for automatic control of Gas Air, Water & Steam and other corrosive media. These direct operated valves work from 0 pressure to their maximum rated pressure. SPECIFICATIONS:Normally Closed: Inlet & Outlet get connected when Solenoid is energised. Normally Open: lnlet & Outlet get connected when Solenoid is De-energised. FDC Series Valves are supplied only in normally closed configuration with flow control. VALVE :
1) Forged Brass, S, Steel 304 & 316 & Aluminium Body 2) Resilient Or Teflon Seating for tight shut - off 3) Pipe Connection -1/8", 1/4" & 3/8 BSP/NPT connection SOLENOID :
1) General purpose solenoid enclosure : IP - 20 & IP - 40 2) Weather proof IP55 3) Water tight, IP66, IP67 & flame proof as per IS-2148 of 1981 for group I, II AS IIB 4) Continuous duty epoxy moulded coils 5) Class F&H Insulation 6) All Solenoid parts in contact with fluid are made of 300 & 400 series S. Steel COIL VOLTAGES :
24, 48, 110,230,440 V AC, 50 Hz 12, 24,48, 110, 230 V DC Installation : Mountable in any position. Features:
Direct operated Packless Tight Shutoff Can be mounted direct on pipe.
TYPE
|
FDC 200/2 Way Direct Operated Midet Type SOLENOID VALVE WITH Flow Control Arrangement.
|
SIZE
|
1/8", 1/4" NPT/BSP.
|
MEDIUM
|
Air, Water, Steam.
|
PORT SIZE
|
3mm.
|
OPT.PRESSURE
|
0 to 15 Kg./cm2.
|
BODY MATERIAL
|
Forged Brass.
|
FLUID TEMP
|
150°C. Max.Valve supplied with flow control arrangement.
|
 | |  |
|
|
 |
|
2-Way-Direct-Operated-Solenoid-Valves
Item Code: 2-Way-Direct-Operated-Solenoid-Valves
FLOCON: 2-Way direct operated solenoid valves have cast Bronze bodies and soft resilient seating which gives complete tight shut off.These Valves are equipped with powerfull Solenoids that provide higher efficiency and flow capacities than most comparable valves. SPECIFICATION: OPERATION: NORMALLY CLOSED : Valve open when Energised close when De-Energised. APPLICATION : (1) Gas Fired Burners (2) Furnaces (3) Boilers (4) Ovens (5) Heating Plants Valve:
1. Direct Operated 2. Pipe Connections Suitable for 1",1 1/2",2" BSP (F) / NPT (F). 3. Cast Bronze body. 4. Soft resilient seating. SOLENOID:1.General Purpose Solenoid Enclosure Nema type 4, IP20, IP40. 2. Dust Proof,Watertight Solenoid Enclosure IP55, IP65. 3. Flame Proof as per IS2148 of 1981 for Group, I,IIA & IIB. 4. Class F, Class H Insulation. 5. Standard Voltages- 24,48,110,220,440 Volts 50 C/s AC. 24,48,110,220, VDC. 6. Ambient-5°C to 50°C. FEATURES:
1. Packless. 2. C. Bronze body. 3. Complete tight shutt off. 4. Continuous duty moulded coil. 5. Silent in Operation. 6. Solenoid capable of being turned 360°. 7. No minimum Operating press required. FLOCON: Valves are made from quality materials and rigorously tested for leakage and performance. Each Valve is subjected to twice the rated voltage plus 1000 Volts at 50 C/s for seconds for insulation test. FLOCON: Valves are guranteed for free replacement against any manufacuturing defect.
TYPE
|
FD 200/2 Way Direct Operated SOLENOID VALVES Full Port Normally Closed only.
|
SIZE
|
1" to 2" BSP/NPT.
|
MEDIUM
|
Air, Water, L.D. Oil, Gas.
|
PORT SIZE
|
Fully Port.
|
OPT.PRESSURE
|
0 to 0.3Kg./Cm2.
|
BODY MATERIAL
|
C.Bronze.
|
FLUID TEMP
|
80°C.Max.
|
 | |  |
|  |
|
 |
 |
|
 |
 |
Servo Operated Solenoid Valves
Item Code: 2-Way-Servo-Operated-Solenoid-Valves
FLOCON: Two way servo operated solenoid valves have compact brass forged bodies and soft seating for complete tight shut off. These valves are equipped with powerful solenoids that provide higher operating pressures and flow capacities than most comparable valves now available. SPECIFICATIONS: OPERATION :
A) Normally Closed: Valve closed when De-energised; open when De-energised. B) Normally Open : Valve opens when energised; closed when De-energised. VALVE :
1) Servo operated with inlet fluid pressure. 2) Pipe connections suitable for 1/4" 3/8" ,1/2" and 3/4" BSP / NPT. 3) Forged brass body. 4) Resilient or Teflon seating. SOLENOID :1) General purpose solenoid enclosure NEMA TYPE 1 2) All solenoid parts made of 300 and 400 series stainless steel. 3) Continuous duty coil. 4) Class F insulation and moulded class B insulation 5) Standard Voltages : 24, 48,110, 220, 440 VA-C.50c/s 24,48,110,220VD-C. 6) Ambient; 5°Cto50 FEATURES:
• Packless. • Forged brass • S.S. valve body • Complete tight shut off. • Compact size. • Continuous duty moulded coil. • Silent in operation. • Full-flow conditions. • Solenoid capable of being turned 360° FLOCON: Valves are made from quality materials and rigorously tested for leakage and performance. Each valve is subjected to twice the rated voltage plus 1,000 Volts at 50C/S for 60 seconds lor Insulation Test. FLOCON: valves are guaranteed for free replacement against any manufacturing defect.
TYPE
|
FS 200/2 Way Servo Operated SOLENOID VALVES Normally Closed and Normally Open.
|
SIZE
|
1/8" to 3/4" BSP/NPT.
|
MEDIUM
|
Air, Water, Inert Gas, L.D. Oil & Steam.
|
PORT SIZE
|
Full Port.
|
OPT.PRESSURE
|
0.3 to 10 Kg./cm2.
|
BODY MATERIAL
|
Forged Brass,S.S. 304, S.S. 316.
|
FLUID TEMP
|
150°C. Max. Higher pressure upto 20 Kg./Cm2 on request.
|
 | |  |
|
|
 |
|
Angle Type Valves
Item Code: 2-Way-Direct-Operated-Valves
FLOCON: 2/2-Way direct operated angle type valves with pneumatic actuator. SPECIFICATION : OPERATION :
A) Normally Closed - In normal position valve is closed by the spring action and the fluid pressure.When the actuator is pressurised, the piston and the plug is lifted up and the valve is open. B) Normally Open - In normal position valve is opened by the spring action and the fluid pressure. When the actuator is pressurised, the piston and the plug is lowered down and the valve is closed. SIZE AND CONNECTION -1/2" BSP (F) / NPT (F) to 2" BS (F) / NPT (F) PRESSURE & TEMP. RATING - as per ANSI class 300.
CONSTRUCTION - Body and Bonnet investment casted, ASTM 351 CF8 (SS304)/CF8M(SS16) SEALING - Soft seated buna nitrile as STD. Optional - Viton, Teflon for max. operating fluid temp, up to 180°C. LEAKAGE - Better than class IV bubble tight, Tight shut-ff class IV in teflon sealing as per ANSI B 16. 104, 1976. STEM AND TRIM - SS 304 / SS 316 GLAND PACKING - Self adjusted, spring loaded teflon v-seals and graphite wiper seals. CHARACTERISTICS - On-Off, Normally closed, Normally open. ACTUATOR - Spring return type Pneumatic cylinder. BODY AND FLANGE - Aluminium - Silicon Alloy solution treated. ACTUATOR SPRING - Spring Steel duly plated. ACTUATOR SIGNAL PRESS - 2.5 to 6 Kg/cm 2 ACCESSORIES - For main Valve 1) Non-return valve 2) Strainer 3) Air lock relay 4) Solenoid Valve 5) Proximity Switch
TYPE
|
FCY 200/2 Way Pneumatically Operated Control Valves Normally Open & Normally Closed.
|
SIZE
|
1/2" to 2" BSP/NPT.
|
MEDIUM
|
Air, Water, Oil, Gas, Steam.
|
PORT SIZE
|
Full PORT.
|
OPT.PRESSURE
|
0 to 10 Kg./cm2.
|
BODY MATERIAL
|
S.S. 304, S.S. 316.
|
FLUID TEMP
|
180°C. Max.
|
 | |  |
|  |
|
 |
 |
|
 |
 |
Diaphragm Operated Valves
Item Code: 2-Way-Diaphragm-Operated-Valves
FLOCON: 2 Way diaphragm operated valves are for normally closed and normally open operation. These valves are ideally used for handing light oils ad fluids upto 300s.s.u. viscosity. NO MINIMUM OPERATING PRESSURE REQUIRED Special valves available for • dry air-gas • continous cycling • exceptionally long life • heavy duty operation • clickless and quiet (noA-C hum operation. APPLICATIONS :
These 2 way valves are extensively used in • Oil furnaces, • Compressors • Pumps • Laundry • Water treatment plants. SPECIFICATIONS OPERATIONS:-:
Two types are available : a) Normally Closed : Valves closed when de - energized, open when energized b) Normally Open : Valves closed when energized, open when de-energized. VALVE :
• Body material • Forged brass • Cast gunmetal • Stainless Steel (300 series) Aluminium • Pipe sizes : 1/4" to 2" BSP / NPT • Seats and discs : Neoprene or Teflon • Operation Pressure : 0 to 10 Kg/cm 2 SOLENOID :
• General purpose enclosure NEMA type 1 • Watertight and dustproof NEMA type 2 & 3R • All solenoid parts in contact with media are made of 300 and 400 series stainless steel. • Continuous duty moulded coil. • Class F insulation • Fluid temperature 95°C. • Electrical Voltages 24,48,110,220,440,Volts 50 C/S 12,24,48,110,220 Volts DC. FETURES :
1. Packless 2. Forged brass body 3. Complete tight shut off 4. Silent in operation 5. Continuous duty mouided Coils 6. Can be mounted in any position 7. Solenoid capable of being turned 360° Installation : A/C Valves can be mounted in any position but DC Valves must be mounted with Solenoid vertical upright. FLOCON: Valves are made from quality materials and rigorously tested for leakage and performance.Each valve is subjected to twice the rated voltage plus 1,000 volts at 50 c/s for the period of 60 seconds for insulation test.
TYPE
|
FSD 200/2 Way Diaphragm Type Pilot Arrangement SOLENOID VALVES Normally Open & Normally Closed.
|
SIZE
|
1" to 2" BSP/NPT.
|
MEDIUM
|
Air, Water, Oil, Gas, Steam.
|
PORT SIZE
|
Full PORT.
|
OPT.PRESSURE
|
0.3 to 10 Kg./cm2.
|
BODY MATERIAL
|
Forged Brass,S.S. 304, S.S. 316.
|
FLUID TEMP
|
80°C. Max.Teflon,Viton Diaphragm can be supplied for higher temperature upto 150°C
|
 | |  |
|
|
 |
|
3 Way Valves
 |
|
 |
FLOCON: Latest 3 way valve design eliminates the orifice connection in the solenoid - all connections are now in the valve body providing in - line piping. This concept with orifice and pipe connections in the body permits coil replacement without opening pipe connections - now necessary on all other 3 Way valves. These valves are commonly used to apply pressure to and vent pressure from cylinders and diaphragms or for selection and diversion of pressure. They also used for automatic control of all gases and liquids non-corrosive to brass and stainless steel. IMPORTANT - NO MINIMUM OPERATING PRESSURE REQUIRED.
SPECIFICATIONS: Operation : Three Types are available : (a) Normally Closed - Applies pressure when Solenoid is eneregised; exhausts pressure when solenoid is de-energised. (b) Normally Open - Applies pressure when solenoid is de-energised; exhausts pressure when solenoid is energised. (c) Universal - For Normally closed or Normally open operation. Selection or diversion of pressure can be applied at 1, 2 & 3 without change of springs or making other adjustments.
VALVE : • ForgedBrass/Aluminium/Stainless steel body. • Resilient or teflon seating for tight shut-off. • Pipe connection suitable for 1/8", 1/4" & 3/8" BSP / NPT / (3/8" available with adapters)
SOLENOID: • General purpose solenoid enclosure (NEMA 1) Weather proof solenoid inclosure(NEMA2&3R) • Continuous duty moulded coil • Class F insulation • All solenoid parts in contact with the • fulid are made of series 300 and 400 stainless steel.
COIL VOLTAGES: Standard. 24,48, 110,230,440VAC 24, 48,110, 230 V DC FREQUENCY OF OPERATION : 650 CYCLES PER MINUTE.
INSTALLATION: Mountable in any position without affecting operation.
FEATURES: • Direct operated • Packless • Complete tight shut off • Compact size • Silent in operation • Solenoid capable of being turned 360° • Can be mounted directly on pipe
FLOCON: valves are made from quality materials and are rigorously tested for leakage and performance. Each valve is subjected to twice the rated voltage plus 1,000 volts at 50C/S for 60 seconds for insulation test.
 | |  |
|  |
|
 |
 |
 |
|
Exhaust Valves
Item Code: 3-Way-Solenoid-Valves
FLOCON: 3 Way quick exhaust valves are versatile. They are internally pilot operated type and incorporate an over size orifice for fast venting of cylinders and diaphragms. These 3 way valves control the flow of gases and liquids by applying pressure to and venting pressure from cylinders and diaphragms. They are used in applications such as pilot operators, single acting cylinders, air compressors, air motors and instrumentation. SPECIFICATIONS:Operation: (a) Normally closed-applies pres sure when solenoid is energised; (b) Normally open-applies pressure when solenoid is de - energised; exhausts pressure when solenoid is energised. VALVE :
• Forged Brass / Aluminium body Internal pilot operated. • Oversize exhaust orifice for fast venting. • Resilient or teflon seating for tight shut off • Pipe connections suitable for 1/4" and3/8"BSP/NPT. • Operating pressure from 0.8 Kg/cm 2 to 15 kg/cm 2 SOLENOID :
• General purpose solenoid enclosure (NEMA1). • Weather proof solenoid enclosure (NEMA2&3R). • All solenoid parts in contact with fluid are made of series 300 and 400 stainless steel. • Continuous duty moulded coil Class B & F insulation • Coil Voltages : Standard : 24,48, 110, 220,440 VAC. 24,48, 110, 220 V DC. FREQUENCY OF OPERATION 250 Cycles per minute. FEATURES:• Packless • Can be mounted in any position without affecting operation • Silent in operation • Compact size • Can be mounted directly on pipe quick Exhaust FLOCON: Valves are made from quality materials and are rigorously tested for leakage and performance. Each valve is subjected to twice the rated voltage plus 1,000 volts at 50 c/s for 60 seconds for insulation test.
TYPE
|
FPQ 300 / 3 Way Pilot Operated SOLENOID VALVES, Normally Closed and Normally Open.
|
SIZE
|
1 / 4" to 1 / 2" BSP/NPT.
|
MEDIUM
|
Air, Water, L.D. OIL.
|
PORT SIZE
|
6mm.
|
OPT.PRESSURE
|
0.8 to 15 Kg./cm2.
|
BODY MATERIAL
|
Forged Brass.
|
FLUID TEMP
|
85°C.Max.A minimum Operating pressure differential must be maintained between inlet and exhaust port 3/8" & 1/2" BSP/NPT Valves will be supplied with suitable adaptor.
|
 | |  |
|  |
|
 |
 |
|
 |
 |
4 Way Solenoid Valves
Item Code: 4-Way-Solenoid-Valves
Our range of 4 way valves is available in wide variety of specifications as per the requirements of clients and area of application. It has the ability to bear temperature up to 80 o C. fabricated making use of the best quality brass and aluminum to ensure high durability and quality. Our range has the following features: FP 400
- Type: FP 400 4 way 5 position single and double solenoid valves direction control for double acting cylinder.
- Size: ¼” BSP/NPT.
- Med.: Air, Water, Light-Oil.
- Port size: 1.5 mm., 2 mm.
- OP. pressure: 0.5 to 10 Kg./Cm2.
- Body material: Forged Brass.
- Fluid temperature: 800C
FSP 400
- Type: FSP 400 4 way 5 port 2 position single solenoid & 3 position double solenoid valves full port for direction control of double acting cylinders.
- Size: ¼” BSP/NPT.
- Med.: Air
- Port size: 6 mm.
- OP. pressure: 1 to 15 Kg./Cm2.
- Body material: Aluminum/Brass
- Fluid temperature: 80oC Max.
FPA 400
- Type: FPA 400 4 way 5 port 2 position single and double solenoid valves full port for high volume actuators and cylinders.
- Size: ¼” to 3/8” BSP/NPT.
- Med.: Air, Water, L.D. Oil.
- Port size: 6 mm.
- OP. pressure: 1 to 15 Kg./Cm2
- Body material: Brass and Hard Anodized Aluminum.
- Fluid temperature: 80oC.
FPA 410
- Type: FPA 410/4 way 4 port 2 position & 3 position high capacity solenoid valves.
- Size: 3/8” to ½” BSP/NPT.
- Med.: air, water, l.d. Oil.
- Port size: 12 mm.
- Op. Pressure: 1 to 15 kg./cm2.
- Body material: Bronze
- Fluid temperature: 80oc. Max.
 | |  |
|
|
 |
|
Flocon Solenoid Valves
 |
|
 |
FLOCON: Aluminium cast 2 way valves are high flow, diaphragm operated angle body specially designed lor reverse jet type dust collectors. The designs have a springless construction with only one moving part, high flow long life and fast opening combine to offer a superior design for the dust collector systems. The high speed operation not only saves the compressed air but it provides the kind of shock wave necessary to free the dust from filter bags. OPERATION : Pulse valve is either operated by internal Solenoid Operator or remote pilot solenoid valve. When the pilot solenoid valve is energised, the air trapped above the diaphragm is quickly exhausted through the pilot solenoid valve causing very fast opening of the main valve. When the pilot solenoid valve is de-energised air supplied through the bleed hole is trapped above the diaphragm, causing to close the valve. CONSTRUCTION :
The Valve body and cover is made out of aluminium alloy castings. The diaphragm and sealing components are made of nitrile rubber. Pipe connection suitable for 1/2", 3/4", 1" and 11/2" BSP(F)/NPT(F). Operating pressure 1 to 10kg/cm2. SOLENOID :
1. General purpose solenoid Nema type 1, IP20. Water tight and dust proof Nema 2 & 3 R, IP55, IP56, IP66, 1P67. 2. Explosion proof as per IS 2148 group I, IIA, IIB approved and certified by C M R S, Dhanbad. 3. All solenoid parts coming in contact with fluid media are made of series 300 and 400 stainless steel. 4. Continuous duty moulded coil for class 'F' & 'H' insulation. 5. Fluid temperature up to 80°C. 6. Coil voltage : 24, 48, 110, 240, 440 Volts 50 C/S AC 12, 24, 48,110, 220 DC. INSTALLATION:
Valves are mountable in any position without effecting their operation, but as a general practice, we recommend to fit the valve keeping solenoid upright and above the header tank. This prevents scale and water entering the valve. The valves are provided with normal BSP female threads. FLOCON: VALVES ARE MADE FROM QUALITY MATERIALS AND ARE RIGOROUSLY TESTED FOR LEAKAGE AND PERFORMANCE. EACH VALVE IS SUBJECTED TO TWICE THE RATED VOLTAGE PLUS 1,000 VOLTS AT 50c/s FOR 60 SECONDS FOR INSULATION TEST.
TYPE
|
FSDA 200/2 Way Pilot Operated Dust Collector SOLENOID VALVES, Normally Closed.
|
SIZE
|
1/2" to 2" BSP/NPT.
|
MEDIUM
|
Air
|
PORT SIZE
|
Full Port.
|
OPT.PRESSURE
|
0.6 to 8.5 Kg./Cm2.
|
BODY MATERIAL
|
Die Cast Aluminium.
|
FLUID TEMP
|
80°C.Max.Teflon,Viton, EPDM,Polyurethane diaphragm can be supplied on request.
|
 | |  |
|  |
|
 |
 |
|
 |
 |
Pressure Regulators
 |
|
 |
APPLICATIONS : FLOCON: 'S latest air filter combination pressure regulator is specially designed to provide precise degree of regulation and flow to operate efficient functioning of pneumatic instruments. The filter element effectively removes the water vapour and other contaminating particles generally present in compressed air supply system. FLOCON: Filler combination pressure regulator is a compact and precise unit to provide clean, dry and regulated air to be used for pneumatic process control instruments, diaphragm control valves, air cylinders and pneumatic tools. FLOCON: In all pressure regulators as the flow is increased the reduced pressure drops from the original reduced pressure setting. The deviation between set pressure and actual pressure is called 'regulator drop'. FLOCON: Minimizes this drop by utilizing an efficient aspirator and separate diaphragm chamber. With increased flow rates the aspirator reates a lower pressure under the diaphragm thus, greater force is applied to the stem and the valve opens further allowing greater air flow to offset the pressure drop. FEATUERS:
1. Suitable for primary pressure up to 15 Kg/ cm 22. Four optinal secondary pressure (0 to 1.4 Kg/ cm 2, 0 to 2.5 Kg/cm 2, 0 to 4 kg/cm 2 and 0 to 7 kg/cm 2.) 3. Choice of ceramic and sintered bronze filter. S. Bronze - 2 to 50 micron Ceramic - 50 micron. 4. Manual drain cock for liquid draining. 5. Rugged aluminium bar stock body. 6. Neoprene diaphragm for sensitive regulation. PRESSURE TEMPERATUREMaximum supply pressure 15 Kg/cm 2Maximum operating temperature 55°C ACCESSORIES & OPTIONS : 1. Pressure gauge 1/4" NPT x 55 mm dia. (Specify suffix 'G') 2. L Bracket (Specify suffix 'L') for field mounting 3. S.S. Internals. (Valve and Spring)
TYPE
|
FCPB Filter Combination Air Filter Regulator for Instrument Air Aluminium Bar Stock Body.
|
SIZE
|
1/4" BSP/ NPT.
|
FILTER
|
Ceramic 50 micron/Sintered Bronze 5 to 50 mircrons.
|
INPUT
|
15 Kg./cm2.
|
OUTPUT
|
0 to 2.5,4,7,10 Kg./cm2.
|
MAX FLOW
|
10 Nm3/hr.
|
 | |  |
|
|
 |
|
 |