We are offering Vibrating Screens and Separators:

ll circular vibratory screener mr model is used to separate solids from liquids or dry material particle sizes up to 33 microns.

Easy to install, can achieve up to 5 separations with networks assembled in a single separator. the diameter of the networks varies from 440 mm to 1. 800.

The ring network is easy and fast to change and can be equipped with cleaning systems such as balls, kleeners, starbrush, cip and the innovative ultrasound system.

The separator can be built upon customer request in stainless steel aisi 316, aisi 304 stainless steel, carbon steel. on request: atex certification, fda procedures, iq-oq, gmp

The mr model can be modified and adapted to customer needs.

View Details & Send Response
Vibrating Screens and Separators

Offering Odour Measuring Device:
  • Continuous odour measurement
  • Redundant sensory measurement in 2 sensor arrays with each time 5 sensors
  • Basis device – complete with gas conditioning
  • Simple assembly:
    • RITTAL system case (3-parts)
  • Analog outputs:
    • 4 ... 20 mA
  • Digital outputs (potential-free)
  • max. 4 measuring points
  • Structure and measuring principle
    The odour measurement by means of the OMD 1.10 is based on the evaluation of the sensor signals. For this sensors with a low selectivity and a high sensitivity are required. In the OMD 1.10 several metal oxide sensors are used. The sample air is sucked in at the measuring gas entries via dust filters, conditioned and then led into the measuring chambers in an alternating way. In the measuring chambers there is each time a sensor array adjusted to the respective case of application. The compensated sensor signal shows a functional correlation to the olfactory determined odour concentration according to experiences. The calibration of the device is done by olfactory reference measurements after VDI 3881.

    View Details & Send Response
    Odour Measuring Device

    Offering Odour Measuring Device:
  • Continuous odour measurement
  • Redundant sensory measurement in 2 sensor arrays with each time 6 sensors
  • Simple assembly:
    • Simple assembly in the analysis cabinet (19"-cabinet)
  • Analog outputs:
    • 4 ... 20 mA
  • Digital outputs adjustable (potential-free)
  • Max. 7 measuring points
  • Tasks
    Due to the increasing sensitiveness of the people odour nuisances from industry, agriculture and waste recycling are tolerated less and less. By means of the odour measuring device OMD 98 the possibility is given to record odour concentrations under industrial conditions continuously. Between the output signals of the sensors and the odour concentrations a functional correlation can be determined by olfactory calibration. As result a continuous statement of the odour concentration as well as a statement of the kind of odour is possible.
    The OMD 98 consists of single modules constructed as 19'-rack and allows on this way the adjustment to different applications. The basic module consists of 2 sensor chambers, the control unit and an automatic pre-dilution. As output a serial interface as well as 2 standardized and freely programmable analogue outputs are available. In addition digital inputs and outputs are offered. The recording of measuring signals can be done on PC with a special software (including automatic pattern identification.

    View Details & Send Response
    Odour Measuring Device

    Offering Gas Flow Measuring Devices:
  • Basic device consisting of probe and control unit
  • Simple assembly:
    • Control unit: wall assembly
    • Probe: Special flange DN 80, PN 6, Di=100 mm
  • Analog outputs:
    • 4 ... 20 mA
  • Digital outputs (potential-free):
    • Limit value 1 (adjustable)
    • Limit value 2 (adjustable) / maintenance request
    • Failure
    • Maintenance
  • Combined device – simultaneous measurement of exhaust gas velocity or flow as well as exhaust gas temperature (optional exhaust gas pressure)
  • Use without control unit possible
  • Application and function
    For the operation of a facility with streaming gases (e.g. hall exhaust air, exhaust gases etc.) the continuous registration of the exhaust gas velocity respectively the flow as well as the temperature are often of substantial importance. In case of continuous emission measurements the mass of pollutants has to be disclosed additionally (mass flow [kg/h]).
    The flow measuring device FMD 99 is a measuring device for the continuous registration of gas velocity and temperature of gas flows in pipelines. Moreover it is possible to display respectively provide the flow in operational or norm state. The use of the dynamic pressure and Pt100-measuring principle guarantees a device simply to install and handle as well as a timely monitoring of the measuring parameters.
    The dynamic pressure probe FMD 99 can be cleaned with the probe cleaning system PCS 03 in case of high dust contents.

    View Details & Send Response
    Gas Flow Measuring Devices

    Offering Multi Gas Analyzer :
  • 19“-rack for the application in e.g. continuous emission measuring systems after gas cooler
  • Cold measurement
  • Measurement of max. 3 infrared components (CO, CO2, NO, SO2, CH4) and Oxygen O2 at the same time
  • Simple assembly in analysis cabinet
  • Analog outputs:
    • Max. 4 x 4 ... 20 mA
  • Digital outputs (potential-free):
    • Limit value 1 (adjustable)
    • Limit value 2 (adjustable) / maintenance request
    • Failure/Error
  • Measuring ranges adjustable
  • Low in maintenance due to automatic calibration with ambient air
  • Check with test gas only every 6 to 12 months
  • View Details & Send Response
    Multi Gas Analyzer

    Offering Oxygen Measuring Device:
  • Compact device consisting of probe
  • Simple assembly:
    • Probe: 1“-sleeve (DIN 2986)
  • Analog outputs:
    • Oxygen: 4 ... 20 mA
  • Digital outputs (potential-free):
    • Limit value 1 (adjustable)
    • Limit value 2 (adjustable) / maintenance request
    • Failure/Maintenance
  • Online line diagram
  • Display in Vol%
  • Fields of application
    The O2MD 04 can be applied for the measurement of the oxygen concentration in smoke, process and cover gases as well as for the mixture and production of special inert gases. Then the concentration of the free oxygen is measured.

    Application and function
    The oxygen measuring device O2MD 04 consists of an in-situ-probe with evaluation electronics and measuring value display in the probe head. The measuring gas flows through the measuring chamber of the probe rod. The core piece of the oxygen measuring device O2MD 04 is a potentiometric ZrO2-sensor. The probe is equipped with a regulated sensor heating and a high-quality electronic which provides the sensor signal (= oxygen concentration) as standard signal.

    View Details & Send Response
    Oxygen Measuring Device

    Offering Dust Measuring Devices:
  • Basic device consisting of probe and control unit
  • Combined device – measurement of dust, exhaust gas velocity or flow as well as temperature (option pressure) at the same time
  • Simple assembly:
    • Control unit: Wall assembly
    • Probe: special flange DN 80 PN 6, Di=100 mm
  • Analog outputs:
    • 4 ... 20 mA
  • Digital outputs (potential-free):
    • Limit value 1 (adjustable)
    • Limit value 2 (adjustable) / Maintenance request
    • Failure
    • Maintenance
    • Measuring range (automatic measuring range change-over)
  • Display dust content in mg/m³ i.N.dr. possible
  • Fields of application
    The dust concentration measuring device PFM 97 is used for the continuous measurement of dust contents, especially for the emission measurement according to TI Air, 13th and 27th BImSchV as well as for the dust concentration measurement in process monitoring. Parallel to the dust measurement flow and temperature of the smoke gas are registered.

    Function principle
    The special probe of the PFM 97 consists of 2 tribo probes and a dynamic pressure probe: The tribo probes register redundantly the raw signal of the dust concentration. In order to correct the velocity influence at the triboelectric measurement the gas velocity is measured by means of a dynamic pressure probe. The synchronous determination of the gas temperature allows the calculation of the dust concentration in norm state.In case of high dust contents the dynamic pressure probe of the PFM 97 can be cleaned with the PCS 03.

    View Details & Send Response
    Dust Measuring Devices


     

    Related Product Catalogs

    Lakshmi Cooling Utility Engineers Private Limited
    Supplying chillers, water cooling tower, water chiller, process chillers, cooling systems, industrial chillers and industrial cooling systems.

    View more details

    Shradhha Enterprise
    Manufacturing and exporting ice making equipment that includes ice making plants, high speed ice making plants, water ice making plants and industrial ice making plants.

    View more details

    Vinita International
    Manufacturer and supplier of electrical air conditioning, water chillers, water coolers, water dispensers, window air conditioner, samsung window air conditioner and central air conditioning.

    View more details

    Suggested Companies


    Related Categories
    Search Suppliers
    CompanyProductsTrade Leads
    OR


    IndiaMARTCompaniesProductsTrade LeadsTendersTrade ShowsTravel
    © 1996-2012 IndiaMART InterMESH Limited. All rights reserved worldwide.