Probe: 1"-sleeve (DIN 2986) optionally flange DN 25 PN 6
Analog output:
Dust: 4 ... 20 mA
Digital outputs (potential-free):
Limit value 1 and 2 (adjustable)
Failure (power failure)
4 Measuring ranges adjustable:
in relation 0,33 : 1 : 3,33 : 10
Application and function The filter controller PFM 92 serves the qualitative monitoring of dusty emissions. In particular it is often used for the registration of the clean gas dust content behind de-dusting facilities. The measuring principle is based on the use of the triboelectric effect (charge transfer at colliding or passing of particles on leading surfaces). The filter controller consists of an isolated probe which is installed in the clean gas channel. The charge transferred by contact and triboelectric processes is derived as current, converted in the evaluation unit, amplified and provided as norm signal 4 ... 20 mA. Via a limit value detector the exceeding of the allowable emission limit value can be signalised optically or acoustically.
Combined device – measurement of dust, exhaust gas velocity or flow as well as temperature (option pressure) at the same time
Simple assembly:
Control unit: Wall assembly
Probe: special flange DN 80 PN 6, Di=100 mm
Analog outputs:
4 ... 20 mA
Digital outputs (potential-free):
Limit value 1 (adjustable)
Limit value 2 (adjustable) / Maintenance request
Failure
Maintenance
Measuring range (automatic measuring range change-over)
Display dust content in mg/m³ i.N.dr. possible
Fields of application The dust concentration measuring device PFM 97 is used for the continuous measurement of dust contents, especially for the emission measurement according to TI Air, 13th and 27th BImSchV as well as for the dust concentration measurement in process monitoring. Parallel to the dust measurement flow and temperature of the smoke gas are registered.
Function principle The special probe of the PFM 97 consists of 2 tribo probes and a dynamic pressure probe: The tribo probes register redundantly the raw signal of the dust concentration. In order to correct the velocity influence at the triboelectric measurement the gas velocity is measured by means of a dynamic pressure probe. The synchronous determination of the gas temperature allows the calculation of the dust concentration in norm state.In case of high dust contents the dynamic pressure probe of the PFM 97 can be cleaned with the PCS 03.
Combined device – simultaneous measurement of exhaust gas velocity or flow as well as exhaust gas temperature (optional exhaust gas pressure)
Use without control unit possible
Application and function For the operation of a facility with streaming gases (e.g. hall exhaust air, exhaust gases etc.) the continuous registration of the exhaust gas velocity respectively the flow as well as the temperature are often of substantial importance. In case of continuous emission measurements the mass of pollutants has to be disclosed additionally (mass flow [kg/h]). The flow measuring device FMD 99 is a measuring device for the continuous registration of gas velocity and temperature of gas flows in pipelines. Moreover it is possible to display respectively provide the flow in operational or norm state. The use of the dynamic pressure and Pt100-measuring principle guarantees a device simply to install and handle as well as a timely monitoring of the measuring parameters. The dynamic pressure probe FMD 99 can be cleaned with the probe cleaning system PCS 03 in case of high dust contents.
Multi Gas Analyzer For Extractive Gas Component Measurement
19“-rack for the application in e.g. continuous emission measuring systems after gas cooler
Cold measurement
Measurement of max. 3 infrared components (CO, CO2, NO, SO2, CH4) and Oxygen O2 at the same time
Simple assembly in analysis cabinet
Analog outputs:
max. 4 x 4 ... 20 mA
Digital outputs (potential-free):
Limit value 1 (adjustable)
Limit value 2 (adjustable) / maintenance request
Failure/Error
Measuring ranges adjustable
Low in maintenance due to automatic calibration with ambient air
Check with test gas only every 6 to 12 months
Fields of application By means of the gas analyser MGA 23 up to 4 gas components can be measured at the same time: maximum 3 infrared-active gases as e.g. CO, CO2, NO, SO2, CH4 as well as O2 with an electrochemical measuring cell.
The gas analyser MGA 23 can be used in emission measuring facilities as well as in systems of process and analysis measuring technology.
For measurements of CO, NO, SO2 and O2 according to 13th respectively 27th BlmSchV and TI Air TÜV-approved versions of the MGA 23 are available.
Smallest TÜV-approved and permitted measuring ranges:
1- and 2-component-analyser
CO2: 0 to 150 mg/m³
NO2: 0 to 250 mg/m³
SO2: 0 to 400 mg/m³
3-component-analyser
CO2: 0 to 250 mg/m³
NO2: 0 to 400 mg/m³
SO2: 0 to 400 mg/m³
All higher measuring ranges are also allowed.
For use in non-potentially explosive atmospheres.
Special configurations: The MGA 23 with 2 IR-components without pump and with or without oxygen is also available with 2 separate gas ways. This allows the measurement of 2 measuring points or e.g. at the NOx-measurement the state before and after converter.
Application examples
Optimisation of small firing systems
Monitoring of exhaust gas concentration from firing systems with different types of fuel (oil, gas and coal) as well as operational measurements in thermal incineration plants
Room air monitoring
Monitoring of air in fruit stores, greenhouses, fermenting cellars and warehouses
Monitoring of process control functions
Ø Monitoring of atmosphere during heat treatment of steel
DESCRIPTION : A heat exchanger is a device in which energy is transferred from one fluid to another across a solid surface. Exchanger analysis and design therefore involve both convection and conduction. Radioactive transfer between the exchanger and the environment can usually be neglected unless the exchanger is uninsulated and its external surfaces are very hot.
SS-316, 304 and 302 stainless steel (Non-corrugated) heat-exchanger to suit the environment to which the material will be subjected in its lifetime.
DESCRIPTION This system is specially designed for giving the Instant cooling effect of any used media during the testing process.
TECH. SPECIFICATION : 1. Compact size- 1200x600x400 MM. 2. Standard powder coated colorful body. 3. Stainless steel water tank capacity-125 or 60 liters. 4. Standard cooling cooper coil 5. Standard cooling Fan motor. 6. Condenser. 7. Water circulation pump flow 1200LPH 8. Auto filling magnetic valve. 9. Powerful PID controller for all safety precaution. 10. Standard manual operated valve.
APPLICATION 1. Conveyer belt cooling process. 2. Chemical cooling process. 3. Industrial use etc.
Redundant sensory measurement in 2 sensor arrays with each time 6 sensors
Simple assembly:
Simple assembly in the analysis cabinet (19"-cabinet)
Analog outputs:
4 ... 20 mA
Digital outputs adjustable (potential-free)
Max. 7 measuring points
Tasks Due to the increasing sensitiveness of the people odour nuisances from industry, agriculture and waste recycling are tolerated less and less. By means of the odour measuring device OMD 98 the possibility is given to record odour concentrations under industrial conditions continuously. Between the output signals of the sensors and the odour concentrations a functional correlation can be determined by olfactory calibration. As result a continuous statement of the odour concentration as well as a statement of the kind of odour is possible. The OMD 98 consists of single modules constructed as 19''-rack and allows on this way the adjustment to different applications. The basic modul consists of 2 sensor chambers, the control unit and an automatic pre-dilution. As output a serial interface as well as 2 standardised and freely programmable analogue outputs are available. In addition digital inputs and outputs are offered. The recording of measuring signals can be done on PC with a special software (including automatic pattern identification) as well as with any kind of measuring value recording or a process control system.
DESCRIPTION : We offer a wide range of Pt100 -rtd sensors, which are known for their best performance. These sensors have long service life. Available in different types, these sensors are also available at market leading prices.
TECH. SPECIFICATION : 1. Teflon shields three core coil type wires. Platinum 100 ohms. 2. body material SST 316 3. Temp. Range up to 350 degree Celsius. 4. Element accuracy: 0.00385 and 0.00375 ohms/C.ALPHA/ TCR 5. Class B (+/-0.12%@C),class A (+/-0.06%@C). 6. Standard transition fitting (200 Celsius or 400 Celsius).
APPLICATION : 1. Water, fluid, chemical and air temperature sensing process etc..
Sancheti International Wholesaler of a wide range of air conditioner parts & refrigeration system spare parts, air conditioner spare parts, from India.