AE was founded in 1942 by the late Mr.M. G. Bhat and the late Mr. L. R. Aneja. At present, the Company is managed by professional Board of Directors, headed by Mr. S. D. Bal and Mrs. V. S. Bal. From its inception has been a pioneer in the field of Electrical AE Instruments, Power Systems and Instrument Transformers in India.
|
 | Moving Iron Ammeters & Voltmeters | | |
| Moving Iron Instruments are protected from damage or breakage under adverse condition due to its spring loaded jewel & pivot system. These Instruments are free from external magnetic field influences because of magnetic shielding & are 'CE' certified. These instruments have a very efficient oil damping system, which gives almost a deadbeat movement to the pointer, without irksome oscillation. The movement is light yet sturdy and has a large torque to weight ratio which assures long life to instruments.
| FEATURES | | • | Scale | Non-linear. | | • | Suppression | Initial suppression for Voltmeter & End suppression upto 6 times for Ammeter. (on request) | | • | Scale Colour | Special colour scales and marks for different ranges, (on request). | | • | Housing | Engineering plastic. | | • | Terminal Protection | Shrouded terminals to protect from accident, (on request). | | • | Glass | Anti - glare. (on request) |
|
 | Moving Coil Ammeters & Voltmeters | | |
Moving Coil Instruments are protected from damage or breakage under adverse conditions due to spring loaded jewel & pivot system. These Instruments are free from external magnetic field influences because of centre magnet system and are "CE" certified. Voltmeters are made upto 600V for direct connection and upto 1200V with / without external multiplier with sensitivity 1000 ohms / V. Higher sensitivities are available. Scale printed for other variables viz. Speed, Temp, pH, kW, kVAR, Hz or Cos ¢ (p, etc. can be supplied on request. | ELECTRICAL SPECIFICATIONS | | • | TYPE | Moving Coil Slide in scale. | | • | OPERATING VOLTAGE | 50mV to 600V. | | • | OPERATING CURRENT | l00nA to 30A. & Above 30A external shunt. | | • | ACCURACY | Class 1.5. | | • | DIELECTRIC TEST | 2kV RMS for 1 min. | | • | OVERLOAD CONTINUOUS | 1.2 times. | | • | OVERLOAD SHORT TIME | 2 times VN / 10 times IN for 5 seconds. | | • | OPERATING TEMP. | -10°C to 55°C. | | • | STORAGE TEMP. | -20°C to 70°C. | | • | HUMIDITY | up to 95% RH | | • | CONFORMS TO | I.S. 1248 / I.E.C. 60051 (Part 2). | | FEATURES | | • | SCALE | Linear. | | • | SCALE COLOUR | Special colour scales & marks for different ranges, (on request). | | • | GLASS | Anti-glare, (on request). | | • | HOUSING | Engineering plastic. | | • | TERMINAL PROTECTION | Shrouded terminals to protect from accident, (on request).
| | |
 | Digital Panel Voltmeter / Ammeter / Frequency Meters | | |
| Digital Panel Meters operate on the principle of dual slope integration. It is available in two types i.e. 3½ digit & 4½ digit. Digital frequency meter incorporates microcontroller with crystal oscillator to display the frequency. It is available in 4 digit type.
| FEATURES | | • | Low cost. | | • | Seven segment red & green colour LED display with 0.5" & 1 " size. | | • | AC current input is incorporated with builtin CT of 1Amp or 5Amp for isolation. | | • | High accuracy. | | • | AC / DC signal measurement |
|
 | Digital Power Factor Meter | | |
It incorporates solid state circuitry with micro-controller to measure Power Factor of single phase and three phase system.
| FEATURES | | • | The Meter does not require external transducer, hence panel wiring is reduced. | | • | Absence of current is indicated by "Err" | | • | Negative sign indicates lagging P.F. | | ELECTRICAL SPECIFICATIONS | | • | TYPE | Single phase/Three phase single element | | • | OPERATIG VOLTAGE | 63.5V/110V/240V/440V., 2VA. | | • | OPERATING CURRENT | 1A/5A, 0.5VA. | | • | RESOLUTION | 0.001 | | • | RANGE | 0.1 Lag - 1 - 0.1 Lead | | • | ACCURACY | ± 2° | | • | AUXILIARY SUPPLY | 110V / 240V ±10%, 50 / 60 Hz, 3VA. | | • | INSULATION RESISTANCE | Greater than 20 Mohms at 500V DC | | • | DIELECTRIC STRENGTH | 2kV RMS for 1 minute. | | • | OPERATING TEMP. | 0°C to 55° C. | | • | STORAGE TEMP. | -20°C to 70°C. | | • | HUMIDITY | Up to 95% RH. | | • | DISPLAY COLOUR | Red |
| |
 | Power Line Transducers | | |
| AE transducers convert various electrical power line parameters viz. Voltage, Current, Frequency, Power Factor, Active power, Reactive power, Apparent power into load independent DC current or voltage output. These are used in various electrical, thermal, chemical & other power plants to monitor processed data either locally or remotely, using various devices such as indicating meters, data loggers, recorders, SCADA systems.
| FEATURES | | • | Open & short circuit protected. | | • | Current and Voltage output are indendent of load impedance. | | • | Measurement of DC parameters. |
|
 | H. V. Tester | | |
Every electrical apparatus or machine Is provided with insulation between live part and earth or between two different sections of live parts. This insulation is required to be tested at high voltage values recommended by applicable relevant standards. The standard Specification for various electrical apparatus specifies Power Frequency Voltage withstand test at different levels depending upon working voltage of electrical apparatus. It is observed from the various standards for electrical equipments that the minimum power frequency voltage withstand test level for electrical insulation is 2kV for one minute. We have, therefore, standardized on manufacture of'AE' High Voltage Breakdown Testers with rated voltage of 5KV. High Voltage Tests Sets of higher voltage upto 600kV are also manufactured against specific requirement. The standard voltages are 10kV, 15kV, 20kV, 25kV, 30kV, 50kV,100kV, 150kV, 200kV & 300kV. The test sets uplo 30kV are manufactured in Air Cooled design while the sets of 50kV & above are manufactured in Oil Cooled design. The output of these high voltage testers is single phase 50/60Hz. The standard H.T. current rating of air-cooled design as also of oil cooled design upto 150kV is 100mA for 30 minutes. For voltages ranges above 'AE' make 5kV A.C. (with 2.5kV tap) High Voltage Breakdown Tester is portable, sturdy & plug in to start type construction & requires minimum table space. It broadly consists of 3 main sections. 1) High Voltage Transformer 2) Variable Voltage Source 3) Control Circuit | |
 | Current & Potential Transformer | | |
| RANGE OF MANUFACTURE :
- Tapewound ring type current Transformers with and without mounting arrangements.
- Tapewound ring type CTs with sealing arrangements.
- Tapewound wound primary CTs (WPL)
- Resincast (epoxy) BPL CTs.
- Resincast (epoxy) wound primary (WPL) CTs.
- Bushing CTs (Fibreglass taped).
|
 | A C Voltage Stabilizers | | |
| Servo - Controlled Automatic AC Voltage Stabilizers of 'AE' make are of 'Electro - Mechanical (EMS) type. The purpose of voltage stabilizer is to receive a fluctuating AC voltage of large amplitude & deliver an almost constant voltage, which remains within a very narrow band (± 1%) of the nominal voltage - quality of the AC voltage remains unchanged. The voltage variations, which have become a common phenomenon in current power supply system, cause havoc in modern complicated & sophisticated equipments. The voltage stabilizers are meant to take care of this problem & protect the equipments. They ensure longer life of the equipments & also drastically cut down electricity consumption of equipments leading to continuous reduction in electricity bills. Thus, they play an important role in energy conservation which is need of the day. | |
|
 Product Showcase View all our products / services as a slide show. play now

|