Current Transformers Our range of outdoor oil cooled current transformers has the following specifications:
| ![]() | |||||||||||||||||||||||
Voltage Transformers Direct measurement of voltage in high voltage system is not possible because of insulation problem in measuring instruments. It is not possible to use voltage through the system directly for protection purpose due to its high value & high insulation problem. In such conditions voltage transformers are used. It has the following features:
| ![]() | ||||||||||||||||||||||||||
Resin Cast Current Transformers H.T. metering cubicals are incorporated with current transformers and potential transformers using resin developed insulating material system, having graded siliceous material and are bonded together with polymer resin system. These moldable materials facilitates integrated design to current carrying and voltage grading components. They can be classified as having:
| ![]() | |||
Resin Cast Potential Transformers We offer potential transformers that are used in current carrying and voltage grading equipment. These are good conductors of electricity and are used in numerous industrial applications. These are available in diverse designs and specifications to suit varying requirements.
| ![]() | |||||||||||||||||||
Relay Testing Equipment The relay testing equipment is a portable apparatus, which is designed for checking the operating characteristics of protective relays on site. Since a relay in the system is called into action to deal with a fault only in a long while, its failure to operate correctly on that occasion means unavoidable damage to plant or waste of money spent on installation. Periodic field testing is the best way of ensuring the integrity of the protective relays, but the position is complicated because of the fact that the protective relay is solely concerned with fault conditions, and hence it cannot readily be tested under normal operating conditions. Specifications : Phase angle regulation
415 volts, 3 phase wire, 50 hz Output I A.C. voltage source with phase shifting arrangement Voltage regulations 0 - 200 volts continuously variable at a max. capacity of 20 V Output II D.C. Voltage source. Range 110 volts with / - 20% with fine control Capacity 250 MA. Instrument digital D.C. Voltmeter, 0 200 volts. Output III D.C. Current source. Range 0 - 1000 ma. Regulation 0 - 1000 ma. continuously variable | ![]() | |||
Voltage Test Kits The knee point voltage test kit is a portable apparatus which is designed for checking the knee point voltage of protection class current transformers having secondary current ratings of 1 A and 5 A. There is a possibility of occurrence of faults in every day operations of electrical power system. Since protection class current transformer in the system is called into action to deal with a fault once in a long while, its failure to operate correctly on that occasion means avoidable damage to plant or waste of money spent on installation. Periodic field testing and testing prior to commissioning of the current transformers is the best way of ensuring the integrity of the electrical power system, since it cannot be readily tested under normal operating conditions. Hence this test kit is a must for every substations. The knee point voltage test kit are voltage injections sets which provide the necessary voltage for both 1 A and 5 A secondary rated protection class current transformers, to check whether their operating characteristics are within the prescribed maximum exciting current limits and do not go into saturation at the prescribed maximum knee point voltage levels of the protection current transformers. A digital current ammeter and voltmeter is provided to record the test values. The test kit is designed to ensure the testing set output without any distortions. Specifications: Input voltage Single phase 230V AC, 50c/s. Output voltage
0 - 100% Duty cycle 5 minutes "ON" and 5 minutes "OFF". | ![]() | |||
Oil Test Sets Oil test set is an equipment designed to test the dielectric strength of insulating oils as per relevant specifications viz. IS 6792. It is a useful equipment for transformer switchgear manufacturing units, oil filtering agencies, repair shops and electrical maintenance. Safety features:
Resin encapsulated H.T. transformer Construction: In a naturally air cooled, portable sheet metal casing (60 KV) models Optional: Motorised version, to uniform increase the output test voltage between 0 - 60KV / 0 - 100KV @ 2KV / Sec. Approx. Specifications: Input 240V Single Phase, 50Hz. A.C. Output 0 - 100KV / 0 - 60KV center top earthed Capacity 2 / 1KVA. Intermittent Indication Mains 'ON' and H.T. 'ON' Lamp Metering 72mm / size back of panel mounting A.C. Voltmeter to monitor output voltage. Protection Electronic, fast acting over current tripping device sensing HT current directly ISS reference IS / 6792 / 1972 latest | ![]() | |||
Current Injection Sets These are low voltage high current A.C. power supplies, output isolated from input. Output may be single range or multi range involving series parallel connections of secondary windings of loading transformer. The primary current injection sets are useful for testing current operated devices such as relays, current transformers etc. This is an asset for electrical testing laboratories, power houses, sub-stations etc. Portable models can be easily taken to the field for on site testing. Accessories: A digital time internal meter with 3.1/2 digit L.E.D. indication in two ranges 0 - 10/100 sec. supply voltage for time internal meter 200 V, 1 phase, Hz A.C. Electrical specifications: Input 240 V, 1 phase, 50Hz A.C. or 415 V, 1 phase, 50Hz A.C. Output 0.1000/2000/3000/4000/6000 AMPS. sleeplessly variable. Capacity 2/4/6/8/10 KVA. Indication Neon lamp Metering 96 mm2 or 144 mm2 size moving iron type ammeter to monitor output current Protection Fuse rewireable / HRC on input lines. MCB in Brush arm of continuously variable voltage auto-transformer. Addititional facility 240 V 1 Ph. supply with switch, fuse for time internal meter. Construction Two piece construction, part I consisting of control and indicating components and part II, consisting of transformer in naturally air-cooled sheet metal casing With covering lid and carrying handles. For laboratory use two sections can be kept side by side on a table. | ![]() | |||
Meter Testing Benches The meter testing benches are designed to work from 3 phase 50 c/s. having voltage 400 to 440 volts between the phases. The test bench is suitable for testing meters under balanced and unbalanced condition of load against rotating sub-standard meters of 5 Amp 240 volts giving accuracy not worse than 0.5. The loading arrangements is based on phantom load principle separate circuit being provided for supplying current and voltage. The bench is provided with indicating instruments of accuracy not worse than 1.5 to indicate Amp and Volts respectively. It is suitable to test 20 Nos. 3 phase meters at a time. Specifications: Current range : 0.5, 1,2.5,10,20,50,100,120 Amps. Voltage range:
The test bench is suitable for testing electricity meters of the following ratings :
| ![]() | |||
Metering Cubicals We offer metering cubicals that can be installed electrically in the incoming supply point and in step down transformers at the consumers installation. These comprises of rigid welded structural frame enclosed completely by M.S. angle of minimum size 50x50x5mm. To ensure the safety of the equipment we enclose all the compartments of the cubicle from inside and with detachable covers and components are bolted. We ensure that the cubicle is compact enough to prevent the ingress of water. All doors and removal covers are gasketed all around with neoprene gaskets and the cubicle meets the requirements of IP-55 protection as per IS-12063, if the air vents are closed. Electronic lock (optional): A dynamic electronic locking system for the cubical shall be offered as optional item. The dynamic lock consist mainly of:
| ![]() | |||