AMF Panel For 15-437 KVA AMF Panel

AMF Panel for 15-437 KVA AMF Panel

If you have a generator at your industry or home as alternate source of electrical supply. What do you do when Main Supply fails Just you go to your generating set in dark to turn it on then you go to your manual changeover and change it to generator supply, when main supply comes again you changeover load to main supply and shut off the genrator. Don't you sometimes fed up from this exercise and want this to be automatic Our AMF Panel is there to help you. Auto Mains Failure (AMF) panel starts Generating set when mains fails then your load is transferred to generator's supply. When Mains supply resumes, it transfers load to Mains supply again and shut off the Generator, everything automatically. AMF panel contains set of relays for automatic start stop of generator, set of electrically operated breakers (Contactors or Air Circuit Breaker depending upon rating of Generator), safety devices for protecting of your Generator from over load and short circuit protection, meters to observe electrical parameters (Voltage, Current, Wattage Energy etc.) and indicating lights to check status of generator and Mains supplies.

Control Panel For 1000-1250 KVA DG

Control Panel for 1000-1250 KVA DG

STANDARD CONTROL PANEL FOR 1000-1250 KVA DG SET Bill Of Material For Our Standard Panel (Rating of switchgears are suitable for Panel KVA Rating. Additional Components can also be provided depending upon Customers requirement) Item 1000 KVA 1250 KVA Ammeter ,96 sq. mm Make - AE/IMP 1600/5, C.T. TYPE 2000/5, C.T TYPE Voltmeter, 96 sq. mm Make - AE/IMP 0-500V 0-500V Frequency Meter, 96 sq. mm Make - AE/IMP 45-55HZ 45-55HZ KW Meter, 96 sq.mm Make - AE/IMP 1600/5 2000/5 PF Meter, 96 sq.mm Make - AE/IMP 1 No. 1 No. Hour Meter, make - Kaycee 41/2 digit 230Vac 41/2 digit 230Vac Voltmeter Sel. Switch Rotary type 10A Make -Kaycee/Salzer R-Y-B-OFF R-Y-B-OFF ACB, 3-pole, Manual Fixed type with O/L Short Circuit Protection, Make L&T 1600A MF 2000A MF Item 1000 KVA 1250 KVA Current Tranformer Tape Wound Type make - MDC/Kappa 1600/5 3 Nos. 2000/5 3 Nos. Control Fuse HRC type Make- S&S/FTC, 6A, 4 nos. 6A, 4 nos. Indicating Light (L.E.D. Type) 230V AC, 24V DC make-FTC 7 nos. 7 nos. Priming Pump Starter (DOL) with O/L Make - L&T 3 HP 3 HP Aux. Relays, Make PLA 5 Nos. 5 Nos. Push Button Make Vaishno 5 Nos. 5 Nos. Hooter 24V DC Make Hella 1 No. 1 No. Dimensions of Standard Control panel in mm Panel Type Height (H) Width (W) Depth (D) Meter Height Cable Connection Clearance 1000-1250 KVA 2000 1200 1350 1750 1000

Control Panel For 15-45 KVA DG Set

Control Panel for 15-45 KVA DG Set

Standard Control Panel are for Generating set of 15-1250 KVA capacity. These Panel contains Circuit breaker (MCB/MCCB/ACB) to protect your Generating set from over load and short circuit protection and meters such as Voltmeter, Ammeter, Hour meter, KW meter, Power Factor meter and Energy meter etc to measure various electrical parameters of your Generating set.STANDARD CONTROL PANEL FOR 15-70 KVA DG SET Bill Of Material For Our Standard Panel (Rating of switchgears are suitable for Panel KVA Rating. Additional Components can also be provided depending upon Customers requirement) Item 15 KVA 25 KVA 30 KVA 40 KVA 62 KVA 70 KVA Ammeter ,96 sq. mm Make - AE/IMP 30A, direct type 40A, direct type 50A, direct type 60A, direct type 100/5, C.T. TYPE 100/5, C.T. TYPE Voltmeter, 0-500V 0-500V 0-500V 0-500V 0-500V 0-500V Frequency Meter, 96 sq. mm Make - AE/IMP 45-55HZ 45-55HZ 45-55HZ 45-55HZ 45-55HZ 45-55HZ Voltmeter Sel. Switch Rotary type 10A Make -Kaycee/Salzer R-Y-B-OFF R-Y-B-OFF R-Y-B-OFF R-Y-B-OFF R-Y-B-OFF R-Y-B-OFF MCB, 3-POLE MAKE- Protec/Havell's 20A 40A 50A 63A X X MCCB, 3-pole Make-Havells X X X X 100A 100A Current Tranformer Tape Wound Type make - MDS/Eltech X X X X 100/5 3 Nos. 100/5 3 Nos. Control Fuse/MCB HRC type Make- S&S/FTC/Protec or Havell's, 6A, 4 nos. 6A, 4 nos. 6A, 4 nos. 6A, 4 nos. 6A, 4 nos. 6A, 4 nos. Indicating Light (L.E.D. Type) make-FTC 2 nos. 2 nos. 2 nos. 3 nos. 3 nos. 3 nos. Dimensions of Standard Control panel in mm Panel Type Height (H) Width (W) Depth (D) Meter Height Cable Connection Height 15-40 KVA 930 520 250 820 175 50-70 KVA 990 560 300 880 100

Control Panel For 50-200 KVA DG

Control Panel for 50-200 KVA DG

STANDARD CONTROL PANEL FOR 75-437 KVA DG SET Bill Of Material For Our Standard Panel (Rating of switchgears are suitable for Panel KVA Rating. Additional Components can also be provided depending upon Customers requirement) Item 75-110 KVA 125-140 KVA 160-180 KVA 200-250 KVA 320-437 KVA Ammeter ,96 sq. mm Make - AE/IMP 150/5, C.T. TYPE 200/5, C.T TYPE 300/5, C.T TYPE 400/5,C.T. TYPE 600/5, C.T. TYPE Voltmeter, 96 sq. mm Make - AE/IMP 0-500V 0-500V 0-500V 0-500V 0-500V Frequency Meter, 96 sq. mm Make - AE/IMP 45-55HZ 45-55HZ 45-55HZ 45-55HZ 45-55HZ KW Meter, 96 sq.mm Make - AE/IMP X X 300/5 400/5 600/5 Hour Meter, make - Kaycee X 41/2 digit 230Vac 41/2 digit 230Vac 41/2 digit 230Vac 41/2 digit 230Vac Voltmeter Sel. Switch Rotary type 10A Make -Kaycee/Salzer R-Y-B-OFF R-Y-B-OFF R-Y-B-OFF R-Y-B-OFF R-Y-B-OFF MCCB with Shunt trip Make-Havells (3-pole) 125/150A 200A 250A 300A/400A 630A Current Tranformer Tape Wound Type make - MDC/Kappa 150/5 3 Nos. 200/5 3 Nos. 300/5 3 Nos 400/5 3 Nos 600/5 3 Nos. Control Fuse HRC type Make- S&S/FTC, 6A, 4 nos. 6A, 4 nos. 6A, 4 nos. 6A, 4 nos. 6A, 4 nos. Indicating Light (L.E.D. Type) make-FTC 3 nos. 3 nos. 3 nos. 3 nos. 3 nos. Dimensions of Standard Control panel in mm Panel Type Height (H) Width (W) Depth (D) Meter Height Cable Connection Clearance 75-140 KVA 1400 560 370 1280 150 160-380 KVA 1700 600 460 1580 350 437.5 KVA 1900 900 600 1750 450

Control Panel For 500-750 KVA DG Set

Control Panel for 500-750 KVA DG Set

STANDARD CONTROL PANEL FOR 500-750 KVA DG SET Bill Of Material For Our Standard Panel (Rating of switchgears are suitable for Panel KVA Rating. Additional Components can also be provided depending upon Customers requirement) Item 500 KVA 625 KVA 750 KVA Ammeter ,96 sq. mm Make - AE/IMP 800/5, C.T. TYPE 1000/5, C.T TYPE 1200/5, C.T TYPE Voltmeter, Meter, 96 sq. mm Make - AE/IMP 0-500V 0-500V 0-500V Frequency Meter, 96 sq. mm Make - AE/IMP 45-55HZ 45-55HZ 45-55HZ KW Meter, 96 sq.mm Make - AE/IMP 800/5 1000/5 1200/5 Hour Meter, make - Kaycee 41/2 digit 230Vac 41/2 digit 230Vac 41/2 digit 230Vac Voltmeter Sel. Switch Rotary type 10A Make -Kaycee/Salzer R-Y-B-OFF R-Y-B-OFF R-Y-B-OFF ACB, 3-pole, Manual Fixed type with O/L Short Circuit Protection, Make L&T 800A 1000A 1200A Item 500 KVA 625 KVA 750 KVA Current Tranformer Tape Wound Type make - MDC/Kappa 800/5 3 Nos. 1000/5 3 Nos. 1200/5 3 Nos Control Fuse HRC type Make- S&S/FTC, 6A, 4 nos. 6A, 4 nos. 6A, 4 nos. Indicating Light (L.E.D. Type) 230V AC, 24V DC, make-FTC 7 nos. 7 nos. 7 nos. Priming Pump Starter(DOL) with O/L Make - L&T 3 HP 3 HP 3 HP Aux. Relays 1no.DOL Make PLA 5 Nos. 5 Nos. 5 Nos. Push Button, Make- Vaishno 5 Nos. 5 Nos. 5 Nos. Hooter 24V DC, Make- Hella 1 No. 1 No. 1 No. Dimensions of Standard Control panel in mm Panel Type Height (H) Width (W) Depth (D) Meter Height Cable Connection Height 500-750 KVA 1900 900 1200 1750 900

Synchronizing Panel

Synchronizing Panel

Expansion of Your Plant: Suppose you have a single Generator of 100kW capacity in your works, capable enough to feed your entire load. Now you have planning to add new machinery in your industries and that causes more power requirement, say 200kW. You are left with two option, one is to discard 1MW set and buy new 200kW set and that you think is expensive, secondly buy another 1MW set and re-distribute your load so that each Generating set can feed 1000W power separately which may not be feasible. Synchronization of two nos. 100kW Generators can solve the problem. These two 1MW sets can be synchronized to feed 200kW and act as virtual single 200kW Generators. Any numbers of DG can be synchronized to meet your increasing load Top | Product Information CRITICAL LOAD Some Industries have critical process machines which require continuous power supply and any momentary interrupt can cause substantial production loss. These machines generally run on Generating set. But when maintenance time of Generator approaches, load has to be cut off from first generator and transfer to another set to start production immediately, however interruption while load transferring sometimes not acceptable Synchronization can avoid this momentarily break in following way, while transferring load to another generator, this generator can be synchronized with running generator and after synchronization, load can be transferred to second set and first set can be shut off for maintenance. So your critical load do not have any interruption at all. Top | Product Information VARIATION IN LOAD ; Power requirement of industries may vary maximum to minimum in a day. For example if in an industries load varies from 70kW to 200kW , instead of having single 200kW generator set one can have two 100kW sets so that during low load single set can be run and as load goes up second DG can be synchronized.This reduces generator maitenance and prolongs its life. effect

AMF Panel For 500-1250 KVA AMF Panel

Meters:- A - Ammeter V- Voltmeter Hz - Frequency Meter KW - KiloWatt Meter PF - Power Factor Meter KWH - Energy Meter HM - Hour Meter Indicating Light:- L1 - Set Running L2 - Load On set L3 - LLOP fault L4 - HWT fault L5 - Battery Charger on L6 - Priming Pump on L7

Spare Breakers:- ACB - Air Circuit Breaker

Switches:- VSS - Voltmeter Sel. Switch BSS - Bus Voltage Sel. Switch ASS - Ammeter Sel. Switch. MAT - Manual/Auto/Test Switch (for AMF operation TBS - Trickle/Boost switch (For Battery charger).


 
 
 