We are engaged in offering wide range of Electrical Relay.


Lead Power Factor Relays

FEATURES

• Software based design

• Display of Power factor, Phase angle and frequency

• Dust proof enclosure

• Draw out type

APPLICATION

JRPv Oil is used to trip (dis-connect) capacitor bank from the line during lead power factor in the system.

PRINCIPLE OF OPERATION

The R-Phase line current input to relay is derived from the line CT. The R - B line voltage scaled to relay rated voltage using transformers. The relay measures the phase angle between R-Current and R-B voltage, the output contact operates when PF reaches lead condition after fixed operating time of 60s. The output contact release when PF reaches lag condition after fixed operating delay of 60s.

The aux supply required for the operation of relay is derived from the voltage input hence no need of dedicated power source.

The relay displays power factor, line frequency, phase angle between line current and voltage.

TECHNICAL DATA

RATINGS

 

Voltage

110V or 415VAC

Current

1A or 5A

Frequency

50Hz ±5Hz

OVER LOAD RATINGS

 

Current input

2 times rated continuous

 

20 times rated for 3s.

 

40 times rated for Is

Voltage input

2 times rated continuous

BURDEN

 

Current input

Less than 0.05 VA at rated 1A

 

Less than 0.2VA at Rated 5A

Voltage input

Less than 10 VA

ACCURACY

 

PF

±0.02 or ±2°

Frequency

± 0.05 Hz

CONTACT RATINGS

 

Contacts

5A at 24V DC / 230V AC

 

 

Send Enquiry

Neutral Earthing Resistor Monitoring Relay

FEATURES

• Solid state reliability

• Built in Trip test facility

• High sensitivity

• Low burden

APPLICATION

The relay is used to monitor the neutral earthing resistor. Transformer neutral is earthed through a resistance. This resistor is called as Neutral Earthing Resistor (NER). Neutral Earthing resistors are used to restrict the fault current through the transformer during earth fault conditions. The healthiness of NER is important as an open resistor would render earth leakage protection in operative and hazardous.

PRINCIPLE OF OPERATION

A very low DC current is passed through the NER and this is monitored in the relay. If there is an open cir­cuit in resistor or considerable change in the resistor value the same is detected in the monitoring circuit. After detecting the change, timer is shorted and output relay is deenergized at the end of internally set time delay ( 5 Sec ) The relay contact may be connected externally to Alarm/Trip circuit as required. Normally the output relay is kept energized. If there is a failure in Aux. Supply the output relay releases and extends the Alarm/Trip signal.

TECHNICAL DATA

SPECIFICATION

 

Auxiliary supply

230V, ±10%, 50Hz

BURDEN

 

Aux. Supply

Less than 5VA

OUTPUT RELAY

 

Relay :

Two Changeover

Relay ratings :

5A at 24V DC/230V AC,

 

50Hz.

Working voltage of the system for which relay :

565V, 3, 50Hz, with neutral earthed through a

is designed

resistance of435 ohms.

Tripping Level :

Resistance more than 150% of 435 ohms i.e.,

 

more than 653 ohms.

 

Send Enquiry

Electrical Reset Auxiliary Relay

APPLICATION

The relay is intended for use in the applications requiring.

1. Increased current-carrying or interrupting capability in a contact (low current contact energizes the coil to close the high current contact)

2. Circuit isolation.

3. Contact conversion ( for example, from a normally open to normally closed condition), or

4. Contact multiplication ( from one contact input to two contact output)

PRINCIPLE OF OPERATION

The applied input voltage creates the magnetic field on the armature and intend to operate or reset the relay.

TECHNICAL DATA

RATINGS

 

Rated voltage

110, 220V, 250V DC & 230V AC

Operated range

75 - 120% of rated voltage

Reset range

75 - 120% of rated voltage

Operating time

Less than 20 ms at rated voltage for series coils Less than 20 ms for coil A & less than 40 ms for coil B at rated voltage - for parallel coils.

Reset time

Less than 30 ms at rated voltage

Operating indicator

Mechanical flag, electrically reset

Contacts

4 N/O + 4 N/C or 6 N/O + 2 N/C

BURDEN

 

Operate Coil

8 Watts (maximum) at rated voltage

Reset Coil

20 Watts (maximum) at rated voltage

ACCURACY

 

Operating value

± 5%

Operating time

± 5% or ± 30msec

Instantaneous time

Less than 40msec.

CONTACT RATINGS

 

Make & Carry continuous (AC - DC)

2500 VA with maxima of 5 A and maxima of 660 V AC

 

2500 W with maxima of 5 A and maxima of 660 V DC

Make & Carry for 3s (AC - DC)

7500 VA with maxima of 30 A and maxima of 660 V AC

 

7500 W with maxima of 30A and maxima of 660 V DC

 

Send Enquiry

Combined Over & Under Voltage Relay

FEATURES

• Software based design

• Wide auxiliary supply

• Low burden

APPLICATION

The relay provides under voltage protection of Motors, Generators, Capacitor Banks etc.

PRINCIPLE OF OPERATION

JRV 014 provides under & over voltage protection for power systems. Relay operating time is determined by set definite time. The relay measures the voltage from input PT and if the voltage is below the set thresh­old, under voltage stage operates and voltage is above the set threshold, over voltage stage operates and it extends a trip signal after the operating time, which is determined by set definite time. The relay output con­tacts are self reset type. TEST button facilitates testing of relay contacts for trip and alarm circuits.

TECHNICAL DATA

RATINGS

 

Voltage rating

110V/230VAC

Auxiliary supply

20 to 60V DC

 

75 to 150V DC

 

175 to 300V DC / 185-250V AC

SETTINGS

 

Under voltage setting

30 to 95% in steps of 5%

Over voltage setting

105 to 170% in steps of 5 %

Definite time

0 to 25s in steps of 0.1s

OVER LOAD RATINGS

 

Voltage input

2 times Rated continuous

BURDEN

 

Voltage input

Less than 2VA at Rated

Auxiliary supply

Less than 3W (Non Operated)

 

Less than 5W (Operated)

ACCURACY

 

Operating value

± 5%

Operating time

± 5% or ± 20ms

Instantaneous Time

Less than 40ms

Drop-off to pickup ratio

80% to 95%

 

Send Enquiry

Under / Over Frequency Relay

FEATURES

• Two stage of frequency protection

• Digital display of line frequency

• Draw out case 144x144 mm

APPLICATION

The relay provides time graded over / under frequency protection. Used in industrial plants having captive power generators requiring under frequency protection.

PRINCIPLE OF OPERATION

The JRF 014 is microprocessor based frequency relay The relay can be configured for

TECHNICAL DATA

RATINGS

 

Frequency rating

50 Hz

Voltage rating

1) 63.5V AC

 

2) 110VAC

Aux. Supply

1) 20 to 60V DC

 

2) 75 to 150V AC/DC

 

3) 175 to 265V AC /DC

SETTINGS

 

Definite time

0.1 to 20.0s in steps of 0.1s

Setting range CHI

45 to 55Hz in steps of 0.01Hz

Setting range CH2

45 to 55Hz in steps of 0.01Hz

Dropout frequency

0.1 to 1.5Hz in steps of 0.l Hz

Low voltage blocking

75% of rated voltage

Evaluation time

5 Cycles

OVER LOAD RATINGS

 

Voltage input

2 times rated continuously

BURDEN

 

Voltage input

0.2VA

DC Aux. Supply

Less than 10W

ACCURACY

 

 

Frequency measurement

±0.01Hz

 

Operating time

±2% or ±5 0ms whichever high

 

Send Enquiry

Digital Time Delay Relay

FEATURES

• Wide setting range

• Bright 7-Segment LED display

• Wide auxiliary supply

• Hand / Self reset type selection

APPLICATION

Digital time delay relay is used to provide delay in a circuit

PRINCIPLE OF OPERATION

The relay can be configured in one of three programmable modes designated as "0100", "0200", "0300". The difference in the functioning of DTDR when configured in the above mentioned modes is restricted to the manner in which its (NO) contacts of DTDR are reset.

DTDR, after sensing the operation (NO -> C) of a potential free contact (Timer Initiation Contact) connected to its terminals [6,7], starts decrementing its "relay operation timer" from an initial value. The ini­tial value of the "relay operation timer" corresponds to "time delay setting". After "relay operation timer" counts down to "0". DTDR operates its NO contacts.

DTDR reset operation in mode - "0100":

"0100" mode corresponds to "Hand Reset" mode. The NO contacts of the DTDR will remain in operated state until further human intervention. Following the operation (NO - > C) of DTDR contacts, DTDR can be reset by pressing "RESET" (RST) switch on the DTDR.

DTDR reset operation in mode - "0200":

"0200" mode corresponds to "TYPE-1 Self Reset" mode. Following the operation (NO -> C) of DTDR contacts, a "self reset timer" will start decrementing from a value equal to "Reset time delay". When this "self reset timer" reaches its terminal count ('0'), DTDR is reset.

DTDR reset operation in mode - "0300":

"0300" mode corresponds to "TYPE-2 Self Reset" mode. Following the operation (NO -> C) of DTDR contacts, DTDR transits to a wait state where it waits for the "Timer Initiation Contact" across [6,7] to change its state from "closed state TO Normally open state". When "Timer Initiation Contact" across [6,7] changes state from "closed state TO Normally open state", a "self reset timer" will start decrementing from a value equal to "Reset time delay". When this "self reset timer" reaches its terminal count ('0'), DTDR is reset.

TECHNICAL DATA

RATINGS

 

Auxiliary Supply

20 to 60V DC

 

80V to 260V AC / DC

SETTINGS

 

Time delay setting

10 to 9990ms in steps of 10ms

Reset time setting

10 to 9990ms in steps of 10ms

Mode of operation

0100-Handreset

 

0200 - TYPE-1 SELF RESET MODE

 

0300 - TYPE-2 SELF RESET MODE

 

Send Enquiry

Lead Power Factor Relay

FEATURES

• Software based design

• Single phase & 3phase measurement

• Dust proof enclosure

APPLICATION

JRR 911 is used to trip (dis-connect) capacitor bank from the line during lead power factor in the system.

PRINCIPLE OF OPERATION

The R,Y and B-Phase line current input to relay is derived from the line CT. The R,Y and B line voltage scaled to relay rated voltage using transformers. The relay measures the phase angle between R,Y and B phase Current and R,Y and B phase voltage, the output contact operates when PF reaches lead condition after fixed operating time of 60s. The output contact release when PF reaches lag condition after fixed oper­ating delay delay of 60s.

The aux supply is required to power up the unit. The relay displays power factor, and lag indication.

TECHNICAL DATA

RATINGS

 

Aux. supply

80 - 260V AC/DC

Current

1A or 5A

OVER LOAD RATINGS

 

Current input

2 times rated continuous

Voltage input

2 times rated continuous

BURDEN

 

Aux. supply

Less than 6W at 110 V DC Aux. supply

Current input

Less than 0.05VA at rated 1A

Voltage input

Less than 0.2VA at rated voltage

ACCURACY

 

PF

±0.02 or ±2°

CONTACT RATINGS

 

Contacts

5A at 24V DC/230V AC

CONTACTS DURABILITY

 

Unloaded contact

1,000,000 Operations

Loaded contact

100,000 Operations

 

Send Enquiry

Contact Us
Mr. Deepak Kotin (Manager)
No. 121, Manchanayakanahalli, Bidadi, 28th K. M., Bangalore - Mysore Highway, Ramanagar
Bengaluru, Karnataka - 562 109, India
Telephone:  +(91)-(80)-27204211/ 27204212/ 27204213

Contact via E-mail

Contact via Mobile

Contact via SMS

Home  |  Profile  |  Products   |  Site Navigation  |  Contact Us  |  Enquiry

Member IndiaMART.com © JVS Electronics Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry