Industrial Components
Our company is recognized for supplying excellently designed and quality range of industrial components which are catered to all major manufacturing industries. We also provide after sales support including installation Training, onsite support. Our assortments are procured from very reliable and renowned vendors based in Chennai and Mumbai. An array of the components is served to domestic as well as global market.
Some of our assortments comprise of following steam boiler, industrial steam boiler, heat exchanger, cooling towers, thermic fluid heater and vertical thermic fluid heater.
 |
|
 |
|
 |
|
 | |
Steam Boiler Item Code: Fully-Automatic-Oil-Fired-Non-IBR Fully automatic non IBR boiler supplied by our company is famous among our clients for maximum efficiency, dependability, easy operation. Our range of the steam boilers is greatly demanded for their cutting edge features and special design. It is available in different models and has following silent features: Salient Features:
- Non IBR Boiler – Maxsteam is exempted from Indian Boiler Regulations.
- Reverse flame technology – Ensures complete combustion.
- Consistent Thermal efficiency of 88% - Ensures low fuel bills
- Fully automatic – Dedicated Boiler attendant not required
- Large tube diameter of coil – Ensures longer coil life
- Multi fuel options – Suitable for HSD/LDO/FO/LPG/Natural Gas
- High unit dependability – All critical components are of reliable make.
- Easy to operate – critical components are accessible for easy maintenance.
- No separate boiler house required – can be installed closed to process equipments.
- Skid mounted – easy to install
- No separate boiler house required – can be installed close to process equipments
- Installing options – (Vertical / Horizontal) for all models.
- Prompt services & spares support, less down time
Built in Safeties and Controls:
- Water level (Low / No) Alarm
- Steam Temperature High Alarm
- Fuel Temperature Low Alarm (For FO unit only)
- Blow Down Valve Open Alarm
- Flame Sensor
- Feed Water Pump Electric Inter Lock
- Sprint Loaded Safety Relief Valve for High Steam Pressure
- High Steam Pressure Switch – Burner On / Off
| |
 |
|
 |
|
 |
 
 
 |
|
 |
|
 |
|
 | |
Heat Exchanger The world's one of the largest ranges of efficient heat exchangers is available for a wide variety of applications. Module based concept is behind the manufacturing of the heat exchangers. Prime components of heat exchanger are Frames, plates and connections. By using different types of plates, with different characteristics, the exchangers can be adapted to a wide variety of applications. The exchangers can easily be taken apart for inspection, cleaning and maintenance. Another benefit of the gasket plate heat exchangers is that they can easily be expanded or adapted, by adding or replacing plates, when the conditions change. Our range is available with following features:
| Flow range |
10-4600 M3/h |
| Working Pressure |
10-25 bar |
| Temperature range |
-20ºC 180ºC |
| Connection |
DN25-DN500 Weld neck, flange or threaded |
Gasketed Plate Heat Exchangers: There are some of the following plates which are widely used for manufacturing of heat exchangers by our manufacturers: GC and GL Plates: Theses are symmetrical plates for regular use. Different plate patterns allow for optimization of thermal transfer or pressure drop. An obtuse angle (high-theta plate) gives high resistance and an acute angle (low-theta plate) a low pressure drop. GX Ultraflex Plates: The plates are available with a herringbone pattern and either an acute or obtuse angle, making it possible to achieve six channel combinations. The Ultraflex design allows the two plates to be turned and rotate, giving six combinations of high – and low theta plate pairs, matching the performance parameters of your application. Ultraflex allows asymmetrical designs, with the primary and secondary circuits designed for heat transfer efficiency. | |
 |
|
 |
|
 |
 
 |
|
 |
|
 |
|
 | |
Cooling Towers Cooling towers are heat removal devices used to transfer process waste heat to the atmosphere. Our range is completely fan less and is excellent in working. It is energy efficient cooling tower with very low maintenance. Assortment of cooling towers has following applications and features: Applications :
- Air Conditioning & Refrigeration Plants
- Chilling Plants
- Air Compressors
- D.G. Sets
- Plastic Moulding Machines
- Process Cooling etc.
Salient Features
- Aesthetic & elegant look
- Totally maintenance free
- Light – weight & compact design
- Algae / Corrosion / Deposit free
- Lower power consumption
- Universal orientation
DeW - Pond offers fiberglass reinforced plastic (FRP) cooling towers incorporating latest technological developments ensuring trouble free and most cost effective operation for the lifetime of cooling towers. Note :
- Capacity is based on temperature drop of 5ºC (i.e. From 37ºC to 32ºC at design WBT of 28ºC) and water flow rate of 13 LPM per TR.
- Cooling towers can be offered without cold water basin if required.
- All civil/electrical / plumbing work is executed from our scope.
- Basin capacity as indicated is for standard basin of 300mm depth. Higher capacity basins can be supplied at extra cost if required.
- For C/TS model DPSQ 200 & above, RCC basin is recommended. However FRP basin can be supplied on request.
Dimensional Details :
| Model |
Cap. (TR) |
Overall Size (LxWxH) mm |
Fan dia No of Blades |
Motor HP /RPM |
I/L x O/L |
Drain- Cum Over Flow |
Make Up |
Op. Wt. (Kgs) |
Basin Cap. (Lits) |
| DPSQ- 5 |
5 |
750 x 750 x1700 |
300/6 |
0.25 /1500 |
11/4” x 11/4” |
½“/½“ |
½“ |
165 |
150 |
| DPSQ- 10 |
15 |
900 x 900 x 2000 |
450/8 |
0.5 /500 |
11/2” x 11/2” |
½ “/½“ |
½“ |
285 |
250 |
| DPSQ- 15 |
15 |
1000 x1000 x 2200 |
600/4 |
1.0 / 500 |
2” x 2” |
¾”/¾” |
½“ |
335 |
300 |
| DPSQ- 20 |
20 |
1100 x 100 x 2200 |
600/4 |
1.0 /500 |
2” x 2” |
¾”/¾” |
½“ |
370 |
300 |
| DPSQ- 25 |
25 |
1200 x1200 x2200 |
750/3 |
| |
 |
|
 |
|
 |
 
 
 |
|
 |
|
 |
|
 | |
Vertical Thermic Fluid Heater Vertical Thermic fluid heater is a
sensible heat transfer machines used for process heating
applications. We are recognized for supplying excellent thermic fluid
heaters with best features and designs. Our assortment if
characterized with large grate area and higher furnace volume. The
company supplies varieties of this heaters range in different designs
and following essential features .
Designed as per DIN 4754
ensures:
- Optimum heat transfer
- Large furnace volume
- Larger distance between flame and
coil
- Low film temperature
- Low tube wall temperature
Machine wound coil manufacturing facility ensures
- No hot spot in the coil
- Longer heater coil life
- Longer thermic fluid life
- High quality materials Input
- Boiler quality tubes conform to BS
3059 Part I from TISCO & TI Group
- All components are of reputed make.
Technical Specifications:
Description
|
Unit
|
MPW- 01
|
MPW- 02
|
MPW- 04
|
MPW- 06
|
MPW-10
|
MPW- 15
|
Rated Output
|
Kcals/ hr
|
1,00,000
|
2,00,000
|
4,00,000
|
6,00,000
|
10,00,000
|
15,00,000
|
Max. Fluid Outlet Temp
|
Deg.C
|
|
|
|
300
|
|
|
Fuel
|
|
|
|
Husk / Wood / Coal
|
|
|
Thermal Efficiency
|
|
|
|
|
|
|
|
On Coal
|
|
|
|
|
76%
|
|
|
On Wood / Husk
|
|
|
|
|
72%
|
|
|
Fuel Consumption
|
|
|
|
|
|
|
|
Coal
|
Kgs/hr
|
29
|
58
|
87
|
175
|
290
|
435
|
| |
 |
|
 |
|
 |
 
|
Our Products
Steam Boiler
Industrial Steam Boiler
Heat Exchanger
Cooling Towers
Thermic Fluid Heater
Vertical Thermic Fluid Heater
|