Have a requirement?
Chat with us
Have a requirement?
Chat with us
Products
- LCD Display Digital Clamp Meter
- AC/DC Current Clamp Adapter
- Digital Clamp Meter
- Professional Grade Digital Clamp Meter
- Data Logging Clamp Meter
- AC TRMS Clampmeter
- DC/AC Autoranging True RMS Clamp-On Meter
- Digital Clamp On Multimeter With VFD Function
- AC Clamp Meter
- AC/DC Digital Dual Display Clamp Multimeter
Digital Clamp Meters
Features :
- Max. conductor size 46.5mm
- Display : 3½ digit with sign Annunciators
- High-accuracy, digital reading
- Large LCD of 21 mm (H) for easy reading
- Instant continuity buzzer
- Overload protection on all ranges
- Recessed safety designed input jacks
- Data-hold, Peak hold & maximum reading possible
- Safety : EN61010-1 protection class II
- Overvoltage Category : CAT III 600V
- Pollution Degree : 2
- Dimension : 250(L) x 100(W) x 46(H) mm
- Weight : 300gms (approx) with battery
- Accessories : Test leads, carrying case, User’s manual, Battery Installed
Additional Information:
- Item Code: 999
View Complete Details
Basic Accuracy : 2.0%rdg + 2dgts ?Average Sensing
CA 500 Current Clamp is a Transducer which will allow your multimeter to measure electrical Current
upto 500Amp AC or DC, with a Frequency response upto 400Hz.
When measuring Current with this Clamp, there is no need to break a circuit or to affect the isolation.
It can be used for waveform analysis by connecting it to an Oscilloscope.
Max. wire length : 3.5 meter when fully stretched.
Operating Temperature : 0°C~50°C; 70% R.H.
Storage Temperature : -20°C to 70°C; 80% R.H.
Power Supply : 9V Battery.
Dimension : 178(L) X 70(W) X 33(H) mm
Weight : Approx. 290 gms
View Complete Details
Digital Clamp Meter
Get Latest Price
- Model KM 111M - Average Sensing - 18 Functions 30 Ranges
- Model KM 112M - True RMS Sensing - 19 Functions 30 Ranges
SPECIAL FEATURES :
- 600A AC Clamp-on + Multimeter ranges
- Ultra-slim jaws to access tight places
- Light weight & compact body to fit your hand
- Fully Auto-ranging for fast measurements
- Input Protection on all ranges
- Fast 30ms MAX Hold to capture in-rush currents
- Relative Zero mode
- Measures non-invasive ACA Frequency via clamp jaws
- Line level frequency measurements
- Data Hold function
GENERAL SPECIFICATIONS :
- Sensing : Average sensing (KM 111M ); True RMS Sensing (KM 112M)
- Jaw Opening Size : 26mm
- Basic Accuracy : 0.5%
- Display : 3¾ Digits 4000 counts LCD display
- Update Rate : 3 per second nominal
- Polarity : Automatic
- Low Battery : Below approx. 2.4V.
- Operating Temperature: 0°C to 40°C.
- Relative Humidity: Maximum relative humidity 80% for temperature upto 31°C decreasing linearly to
50% relative humidity at 40°C - Altitude : Operating below 2000m
- Storage Temperature : -20OC ~ 60OC,< 80% R.H. (With Battery removed)
- Temperature Coefficient : Nominal 0.15 x (specified accuracy) / OC @ (0OC ~ 18OC or 28OC ~ 40OC),
or otherwise specified. - Power Supply : Single 3V coin Battery IEC CR-2032.
- Power Consumption : 2.8mA typical, except 3.3mA typical for current function.
- APO Timing : Idle for 30 minutes.
- APO Consumption : 5mA typical.
- Dimension : 190(L) x 63(W) x 32(H)mm
- Weight : Approx. 139gm
Safety :
- Safety : Meets IEC61010-2-032, EN61010-2-032, UL61010B-2-032, IEC61010-1 2nd Ed.,
EN61010-1 2nd Ed., UL61010-1 2nd Ed.
Measurement Category : CAT III 600 Volts AC & DC. - Pollution degree : 2
- E.M.C. : Meets EN61326 (1997, 1998/A1), EN61000-4-2 (1995, 2000/A2), and EN61000-4-3 (2002)
In an RF field of 3 V/m :
Capacitance function is not specified.
Total Accuracy = specified Accuracy + 65 digits.
Other function ranges :
Total Accuracy = Specified Accuracy + 45 digits.
Performance above 3V/m is not specified. - Overload Protections :
ACA Clamp-on jaws : AC 600A rms Continuous.
+ / mA & COM terminals : 600VDC / VAC rms. - Transient protection : 6.5KV (1.2/50mS surge)
- Rugged Fire-retarded casing
ACCESSORIES : Test lead pair, Battery installed, User’s Manual & Carrying case
Additional Information:
- Item Code: KM-111M-KM-112M
View Complete Details
Professional Grade Digital Clamp Meter
Get Latest Price
- Versatile & Handy
- DC 1000A / AC 800 A Clamp-on + Full Multimeter ranges
- 50mm Large Jaws opening
- Fully Auto-ranging on all functions for ease of use
- Backlighted Display (Only for Model 2754A-T)
- 30ms Max HOLD to capture IN-Rush currents
- Data Hold & Relative Zero feature
- Battery cover with Probe holders
- Rugged Fire retarded casing.
- Transient protection 6.5kV (1.2/50µS lightning surge
- LVD EN61010-2-032 CAT III 600V
- EMC EN61326 (97/98A1) / EN61000-4-2 (95) / EN61000-4-3(96)
General Specifications :
Display | 3¾ digits 4000 counts |
Update Rate | 3 per second nominal |
Polarity | Automatic |
Operating Temperature | 0oC ~ 40oC |
Relative Humidity | Maximum relative humidity 80% for temperature upto 31oC decreasing linearly to 50% relative Humidity at 40oC |
Altitude | Operating below 2000m |
Storage Temperature | -20oC ~ 60oC, <80% R.H. (With battery removed) |
Temperature Coefficient | Nominal 0.15 x (specified accuracy) / oC @ (0oC ~ 18oC or 28oC ~ 40oC), or otherwise Specified |
Sensing | Average (2754A) / TRMS (2754A-T) |
Safety | Meets IEC61010-2-032(2002), EN61010-2-032 (2002), UL61010B-2-032(2003) |
Measurement Category | CAT III 600V AC & DC |
E.M.C | Meets EN61326(1997, 1998/A1), EN61000-4-2 (1995), & EN61000-4-3 (1996) |
In an RF Field of 3V/m | Capacitance function is not specified Other function ranges Total accuracy = Specified accuracy + 45 digits. Performance above 3V/m is not specified |
Overload Protection | Clamp-on jaws : DC 1000A or AC 800A rms continuous + & COM terminals : 600 VDC / VAC rms |
Pollution Degree | 2 |
Transient Protection | 6.5kV (1.2/50µs) surge |
Low Battery | Below approx. 2.5V |
Power Supply | Standard 1.5V AAA Battery x 2 |
Power Consumption | Typical 11mA for DCA / ACA & 2.9mA for other functions |
APO Consumption | 190µA typical |
APO timing | Idle for 30 minutes |
Dimension | 227(L) x 78(W) x 40(H) mm |
Weight | approx 290 gm |
Jaws Opening & Conductor Diameter | 50mm Max |
Accessories | Test Leads pair, Batteries installed, User’s Manual, Carrying case |
Additional Information:
- Item Code: 2754A-2754A-T-TRMS
View Complete Details
Data Logging Clamp Meter
Get Latest Price
general specifications :
jaw opening & conductor diameter | 45mm max |
display | voltage functions : 6000 counts lcd display ohms & hz functions : 9999 counts lcd display aca clamp-on function: 4000 counts lcd display |
update rate | voltage, aca clamp-on, ohms & temperature functions : 4 per second nominal hz function: 2 per second nominal |
polarity | automatic |
low battery | below approx. 2. 4v |
operating temperature | 0oc to 40oc |
storage temperatures | -20oc ~ 60oc, <80% r. H. (with battery removed) |
power supply | standard 1. 5v aaa siz battery x 2 |
dimension | l224mm x w78mm x h40mm |
weight | 224gm approx |
accessories | test leads (pair), batteries installed, user’s manual, & soft carrying pouch pc interface kit banana plug type-k thermocouple etc. |
hi-lo logging mode : a unique feature of this instrument is hi-lo logging mode due to this feature field monitoring is made simpler & affordable. Hi-lo logging captures the most important surges (hi) & sages (lo) on intervals of every one minute. The meter uses its highest update rate to compare & capture the highest & lowest reading on every one minute time interval .
it can log upto 5400 pairs of hi/lo readings and thus 5400 minutes of logging period when the meter memory is full or the meter battery is low, the meter will stop (end) the hi-lo logging session & go back to normal measuring mode
safety :
safety | meets iec61010-2-032(1994), en61010-2-032(2002), ul3111-2-032(1999). Category iii 600 volts ac & dc |
e. M. C | meets en61326(1997,1998/a1),en61000-4-2(1995), and en61000-4-3(2002) in an rf field of 3v/m; total accuracy = specified accuracy + 45digits performance above 3v/m is not specified |
overload protection | aca clamp-on jaws : ac 1000a rms continuous + & com terminals (all functions) : 600vdc/vac rms |
transient protection | 6. 5 kv (1. 2/50 µs surge) |
pollution degree | 2 |
measurement catagory | cat iii 600 volts ac & dc |
Additional Information:
- Item Code: KM-135
View Complete Details
AC TRMS Clampmeter
Get Latest Price
General Specifications :
Jaw opening & Conductor diameter | 45mmMax |
Display | 3-5/6 digits 6000 counts |
Update Rate | 5 Per second nominal |
Polarity | Automatic |
Transient Protection | 6.5 KV lightning Surge(1.2/5 µs) |
Pollution Degree | 2 |
EMC | Meets 61326 (1997, 1998 / AI), EN 61000 -4-2 (1995) & En 6100-4-3 (1996) In an RF field of 3 V/m : Capacitance function is not specified. Other Function Ranges : Total accuracy = specified accuracy + 45 digits Performance above 3 V/m is not specified. |
Overload Protection | ACA Clamp on jaws : AC 2000 A rms continuous + & com terminal (all functions) : 600 VDC & VAC rms |
Low Battery indication | Below approx. 2.4 v |
APO consumption | 230 µA typical on voltage & current function , 40 µA on other ranges |
Dimension | 224 (L) X 78 (W) X 40 (H) mm |
Weight | Approx 220 gms |
Safety | Meets IEC 61010-2-032 2nd Ed.(2002), UL 3111-2032(1999) |
Measurement Category | CAT III 600VAC & VDC |
Power Supply | 2X1.5V AAA batteries |
Special Features | Autocheck TM (Automatic V & Selection); L0-Z voltage measurements(Can eleminate ghost voltage); EF-detection |
Accessories | Test leads(pair),batteries installed, users manual, soft carrying Pouch |
Additional Information:
- Item Code: 2772
View Complete Details
DC/AC Autoranging True RMS Clamp-On Meter
Get Latest Price
- model km 061 - average sensing - 18 function 37 ranges
- km 062 - true rms sensing - 20 function 37 ranges
special features :
- measure line-level acv frequency via test leads
- relative zero feature
- 4000 counts high resolution, fast measurements
- versatile & handy
- backlight display (km 062)
- fully autoranging on all functions for ease of use
- ac true rms voltage & current functions (km 062)
- 30ms max hold to capture in-rush currents
- dca / aca 0. 1a to 400a non-invasive current measurements.
- display hold, peak-rms max hold & data hold
- fast audible continuity
- diode test
general specifications :
- sensing : average sensing ((km 061) ; true rms sensing (km 062)
- jaw opening & conductor diameter : 30mm max
- display : 3-3/4 digits 4000 counts lcd display
- update rate : 3 per second nominal
- polarity : automatic
- low battery : below approx 2. 4v
- operating temperature : 0°c to 40° c
- relative humidity : maximum relative humidity 80% for temperature upto 31oc decreasing linearly to 50%
relative humidity at 40°c - altitude : operating below 2000m
- storage temperature : -20°c to 60°c, < 80% r. H. (with battery removed)
- temperature coefficient : nominal 0. 15 x (specified accuracy) / °c @ (0oc-18oc or 28oc-40oc),
or otherwise specified - power supply : standard 1. 5v aaa battery x 2.
- power consumption : dca & aca : 11ma typical
other function : 2. 9ma typical - apo timing : idle for 30 minutes
- apo consumption : 190ma typical
- dimension : 188(l) x 63(w) x 40(h) mm
- weight : approx. 218 gms
safety :
- meets iec61010-1 2nd ed. , en61010-1 2nd ed. , ul61010-1 2nd ed. , iec61010-2-032, en61010-2-032,
ul61010b-2-032. - measurement category : cat iii 600 volts ac & dc
- transient protection : 6. 5kv (1. 2/50ms surge)
- pollution degree : 2
- e. M. C. : meets en61326-1:2006 (en55022, en61000-3-2, en61000-3-3, en61000-4-2 / 3 / 4 / 5 / 6 / 8 / 11.
in an rf field of 3v/m :
capacitance function is not specified.
other function ranges :
total accuracy = specified accuracy + 50 digits
performance above 3v/m is not specified - overload protections :
clamp-on jaws : dc / ac 400a rms continuous
+ & com terminals (all functions) : 600 v dc / v ac rms - 600v ac / dc input protection on all functions
- battery cover with probe holders
- rugged fire retarded casing; soft carrying pouch
- lvd en61010-1 & en61010-2-032 cat iii 600v
accessories : test leads (pair), battery installed, user's manual & carrying case
View Complete Details
Digital Clamp On Multimeter With VFD Function
Get Latest Price
SPECIAL FEATURES :
- VFD-V & VFD-Hz function
- 5ms CREST-MAX capture mode (Peak Hold)
- Autoranging Relative -Zero mode
- Data Hold function
- EF-Detection (NCV)
- PC Interface (Optional)
- AutoCheck Voltage & Ohms
- Hz Line Level Frequency
- Manual / Autoranging range selection.
- Auto Power Off
- Diode Test & Continuity Test
GENERAL SPECIFICATIONS :
- Sensing : Average sensing
- Jaws Opening size : 26 mm Max.
- Display : 3-5/6 digits 6000 counts &
3½ digits 1,999 counts for Hz. - Update Rate : 5 per second nominal
- Polarity : Automatic
- Low Battery : Below approx 2.4V
- Operating Temperature : 0°C to 40°C
- Relative Humidity : Maximum 80% R. H. For
temperature upto 31°C
decreasing linearly to 50%
Relative Humidity at 40°C - Altitude : Operating below 2000m
- Storage Temperature : -20 C to 60 C, < 80% R.H.
(With battery removed) - Temperature Coefficient : nominal 0.15 x
(specified accuracy) / °C @
(0°C--18°C or 28°C--40°C),
or otherwise specified - Power supply : Standard 1.5V AAA Battery x 2.
- Power Consumption : 5.2mA typical
- APO Timing : Idle for 34 minutes
- APO Consumption : 10mA typical
- Dimension : 190(L) x 63(W) x 32(H) mm
- Weight : Approx. 179gm.
Additional Information:
- Item Code: KM-181
View Complete Details
AC Clamp Meter
Get Latest Price
Features :
- Conductor size is 26 mm
- 31/2 Digits LCD (1999 counts)
- Auto Polarity Display
- Measurement speed is 3 times/second
- Data Hold, Max Hold facility
- IEC 61010 CAT II 600V, CAT III 300V over voltage and double insulation standard approved
- Low Battery Indication
Dimension | : | 208mm x 76mm x 30mm |
Weight | : | Approx 260 grams (including Battery) |
Power | : | 2 x 1.5 V battery (AAA) |
Accessories | : | Carrying case, Batteries installed, Temp. Probe, Drop Proof wrist strap, Manual, Test Leads |
Additional Information:
- Item Code: 2718
View Complete Details
AC/DC Digital Dual Display Clamp Multimeter
Get Latest Price
special features :
- dual display 6000 counts (1 display in front & 1 display at bottom)
- auto / manual range selection
- relative measurement display “δ” sign.
- the knife like part at the top side of clamp allows user to separate the wires without touching with hand & helps in increasing safety while taking measurement.
- analog bar graph display
- automatic zero adjustment.
- low battery indication.
- data hold function.
- led light for proper connection in dimly light areas, which turns on when the clamp jaws are opened.
- magnet at the back side of meter allows user to fix the meter on metal surface making the measurement procedure easy
general specifications :
- sensing : ac true rms sensing
- jaw size : 65mm
- polarity : automatic negative polarity indication.
- over range indication : the “ol” or “-ol” display.
- auto power off : after approx. 15 minutes
- operating temperature : 0°c ~ 40°c (32°f~104°f); relative humidity ≤ 80% r. H.
- storage temperature : -20° c ~ 60°c (-4°f~140°f); relative humidity ≤ 90% r. H.
- power supply : standard 9v battery.
- dimension : 275(h) x 120(w) x 32(d) mm
- weight : approx. 562gm. (including battery)
safety :
- safety : the meter is up to the standards of iec1010 double insulation.
- pollution degree : 2
- ce emc/ lvd.
- cat ii 1000v.
- overvoltage cat ii.
accessories : test leads (pair), user’s manual, & carrying case
Additional Information:
- Item Code: 860A
View Complete Details
need