Have a requirement?
Chat with us
Have a requirement?
Chat with us
Products
- Digital Multimeter With Non-Contact EF-Detected
- Digital Multimeter with VFD Feature & PC Interface
- Dual Display Digital Clamp Meter
- Digital Automotive Test Meter
- Digital Multimeter with Terminal Locking System
- Auto Ranging Digital Multimeter
- Mobile Logger Digital Multimeter
- Environmental Multimeter
- Hand Held Digital Multimeter
- Dual Display TRMS Digital Multimeter
- Digital Multimeter with EF-Detection & Computer Interface
- Digital TRMS Multimeter Mobile Logger
- Dual Display Digital Multimeter with VFD Feature
- Digital Multimeter with Analog Bar Graph
- 54/5 Digits Hand Held Digital Multimeter
- Voltage Tester
Digital Multimeters
We supply Digital Multimeters that are widely used in measuring the accurate readings of voltages and currents in various sectors. Our range of these Multimeters is highly demanded for their long functional life, accuracy, reliable performance and user friendly nature. We offer these to our clients at nominal prices in the industry. These meters are easy to carry and maintain. |
Digital Multimeter With Non-Contact EF-Detected
Get Latest Price
- model km 655 - 15 functions 38 ranges
- model km 656 (trms) - 16 functions 38 ranges
special features :
- fully auto-ranging
- max / min recording mode
- low battery indication
- non-contact ef-detection (ncv)
- probe-contact ef-detection for more precise indication of live.
- line level frequency 40hz to 60khz
- fast measurements, 5/sec
- intelligent auto power off & data hold
- beep-jack input warning against improper a-terminal plug in
- fast audible continuity < 100ms
- diode tester
general specifications :
- sensing : average sensing (km 655); trms sensing (km 656)
- basic accuracy : 0. 5%
- display : 3-5/6 digits 6000 counts large easy to read lcd display
- update rate : 5 per second nominal
- operating temperature : -10°c~50°c
- relative hunidity : maximum relative humidity 80% for temperature upto 31°c decreasing
linearly to 50% r. H. At 50°c - altitude : operating below 2000m
- temperature coefficient : nominal 0. 15 x (specified accuracy) / °c
@ (-10°c~18°c or 28°c~50°c), or otherwise specified. - low battery indication : below approx. 5. 5v.
- power consumption (typical) : 3ma
- apo consumption : 20ma typical except 50ma for a function
- apo timing : idle approx. > 30 minutes
- power supply : standard 9v battery.
- dimension : 173(l) x 83(w) x 48. 5(h)mm
- weight : approx. 300gm.
safety :
- safety : the meter is protected, against the users, by double insulation per
en61010-1, iec61010-1, 2nd ed. , ul61010-1 2nd ed. & can/csa
c22. 2 no. 61010-1 to “cat iii 1000v & cat iv 600v”.
terminals (to com) ratings:
v : category iii 1000 volts ac & dc, and cat iv 600 volts ac & dc
a : cat iv 600v ac & 500v dc
over load protection:
v : 1050v rms, 1450v peak.
a : 15a/600v, ir 100ka, f fuse - transient protection : 8kv(1. 2/50ms) lightning surge.
- pollution degree : 2
- e. M. C. : meets en61326(1997, 1998/a1), en61000-4-2(1995) & en61000-4-3(1996)
in an rf field of 3v/m :
a) capacitance function is not specified
b) other function ranges : total accuracy = specified accuracy + 45d
c) performance above 3v/m is not specified. - rugged fire retarded double injected casing
- 600v (input protection in all ranges. )
- battery access door with probe holders
- lvd meets en61010-1 cat iii 1kv & cat iv 600v
accessories : test lead pair, battery installed, manual & carrying case
optional accessories :
- current clamp ca300,
- current clamp adaptor ca500, ca1000, ca2000,
- high voltage probe pd-28
View Complete Details
Digital Multimeter with VFD Feature & PC Interface
Get Latest Price
Special Features :
- Beep-Jack Audible & Visible Input Warning
- 41 Segment Analog Bar-graph
- Relative Zero Mode
- PC Interface Capability
- VFD-V & VFD-Hz readings
- Crest (Instantaneous Peak Hold) function
- T1-T2 differential Temperature readings
- 500,000 counts stable DCV mode
Features :
- DC Voltage Basic Accuracy 0.02%
- AC; AC+DC True RMS Conversion AC. AC+DC Voltage Bandwidth upto 100kHz (V) & 10kHz (A)
- 5-4/5 Digit 500,000 counts large easy to read LCD Dual display with white Backlight
- Fast Measurements, 5/sec; Fully Auto-Ranging
- Record MAX, MIN & AVG. readings
- MAX & MIN readings & Data Hold Function
- dBm function with 20 selectable values
- High speed Capacitance measurement
- 1000V General Input Protection
- Logic & Line Level Frequency
- Logic Level Duty Cycle Readings & Diode Tester
- Fast Audible Continuity & Diode tester
- Auto Power Off
General Specifications :
- Display : 4-4/5 Digits 50,000 counts fast mode. Selectable stable mode 5-4/5 Digits 500,000 counts for DC Voltage & 5 digits 99,999 counts for Hz
- Polarity : Automatic
- Update Rate : 4-4/5 Digits fast mode : 5 per second nominal; 5-4/5 Digits stable mode : 1.25 per second nominal; 41 Segments Bar-graph : 60 per second max
- Sensing : AC, AC+DC True RMS
- Operating Temperature : 0°C to 45°C
- Relative Humidity : Max. 80% R.H. for Temperature up to 31°C decreasing linearly to 50% R.H. at 45°C
- Pollution Degree : 2
- Storage Temperature : -20°C to 60°C, <80% R.H. (with battery removed)
- Altitude : Operating below 2000m
- Temperature Coefficient : nominal 0.15 x ( specified accuracy)/°C @ (0°C ~ 18°C or 28°C ~ 45°C), or otherwise specified
- Power Consumption : 6.5mA typical; 8mA for VFD ranges
- Low Battery : Below approx 7V
- APO Timing : Idle for 17 minutes
- APO Consumption : 70µA typical
- Power Supply : Single 9V battery
- Weight : Approx. 635gm with holster
- Dimension : 208(L) x 103(W) x 64.5(H) mm with holster
- Accessories : Carrying case, One BKP60 banana plug type-K Thermocouple
- Optional Accessories : PC interface kit, Bkb32 banana pins to K-type socket plug adaptor & Magnetic Hanger
Safety :
- Double insulation per IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed., & CAN/CSA C22.2 No. 61010.1-0.92 to Category IV 1000V AC & DC
- Transient Protection : 12 kV (1.2/50µs surge)
- Terminals (to COM) Measurement Category : V/A/mAmA : CAT IV 1000V AC & DC
- Overload Protection : mA & mA : 0.44A/1000V, IR 10kA or better, F Fuse A : 11A/1000V, IR 20kA or better, F Fuse V, mV, & Others : 1050Vrms, 1450Vpeak
Additional Information:
- Item Code: KM-869
View Complete Details
Dual Display Digital Clamp Meter
Get Latest Price
General Specifications :
Display | 3¾ digits 4000 counts LCD displays |
Update Rate | 3 per second nominal |
Polarity | Automatic |
Low Battery | Below approx. 2.4V |
Operating Temperature | 0oC to 40oC, <80% R. H. |
Altitude | Operating below 2000m |
Storage Temperature | -20°C to 60°C, <80% RH (with battery removed) |
Temperature Coefficient | Nominal 0.15x (specified accuracy)/oC@(0°C-18oC or 28oC-40oC), or otherwise specified |
Sensing | Average sensing. |
Power supply | 1.5V alkaline 4 button batteries. |
Power Consumption | 2.5 µA typical |
APO Timing | Idle for 30 minutes |
APO Consumption | 0.8µA typical. |
Dimension | 190(L)mm x 63(W)mm x 32(H)mm |
Weight | 187gm approx. |
Jaw Opening & Conductor Size | 26mm Max. |
Accessories | Test leads(pair), Batteries installed, User’s manual & Soft carrying case |
Safety Features :
Safety | Meets IEC61010-2-032(1994), EN61010-2-032(1995), UL3111-2-032(1999), CAT III 600V AC & DC |
Transient protection | 6.5KV (1.2/50µS surge) |
Pollution degree | 2 |
E.M.C | Meets EN61326 (1997, 1998/A1), EN61000-4-2(1995), and EN61000-4-3(1996) In an RF field of 3V/m : Capacitance function is not specified µA : Total Accuracy = Specified Accuracy + 65 digits Other function rangesTotal Accuracy = Specified Accuracy + 45 digits Performance above 3V/m is not specified |
Overload Protections | ACA Clamp-on jaws : AC 400A rms continuous + µA & COM terminals on all functions : 600VDC/VAC rms |
Additional Information:
- Item Code: 2799
View Complete Details
Digital Automotive Test Meter
Get Latest Price
specifications :
basic function | |
dc voltage | 2v/20v/200v/1000v |
ac voltage | 2v/20v/200v/1000v |
dc current | 200ma ~ 20a |
ac current | 200ma ~ 20a |
resistance(? ? ? ) | 200/2k/20k/2m/200m |
capacitance | 20n/2/200f |
temperature | -40oc ~ 1000oc |
dwell | 1/3/4/5/6/8 cyl |
tach | 1/3/4/5/6/8 cyl |
special features :
- display : 3½ digits (1999 counts)
- diode test, hfe test, continuity test, data hold, backlight display & duty cycle
- overload protection in all ranges
general characteristics :
power supply | : | 9v battery. |
lcd size | : | 65 x35mm |
meter weight | : | 445g |
size | : | 205 x 100 x 60mm |
standard accessories | : | test lead, battery, manual, k-typ thermocouple probe, carrying case. |
note: all specifications are subject to change. |
Additional Information:
- Item Code: KM-6060
View Complete Details
Digital Multimeter with Terminal Locking System
Get Latest Price
features : low power consumption cmos double integration, a/d transform integrated circuit, auto zero calibration, auto polarity display, data hold, low battery & over range indication.
display | : | 3½ digit (2000 counts) with digit height 28mm and function/units sign annunciators. |
selected range displayed on lcd. | ||
test lead jack mechanical protection function & full range over-load protection function. | ||
polarity | : | automatic (-) negative polarity indication. |
over range indication | : | most significant digit becomes ‘1’, indicates that the value has exceeded the selected range. . |
auto power off | : | the meter will shut off automatically about 15 minutes after power is on to avoid forgetting to turn off the meter after using it. |
operating temperature | : | 0°c to 40°c |
relative humidity | : | < 85% |
storage temperature | : | -10°c to 50°c |
relative humidity | : | < 85% |
temperature for keeping accuracy | : | 23°c ± 5°c |
relative humidity | : | < 75% |
power | : | one standard 9v battery |
low battery indication | : | will occur on the left top of the lcd. |
dimension | : | 192mm(l) x 88mm(w) x 42mm(h) |
weight | : | approx. 600g. (including battery and holster). |
safety | : | ce mark certified |
accessories | : | test leads, temperature probe, holster, user manual, carrying case, battery |
Additional Information:
- Item Code: KM-6030
View Complete Details
Auto Ranging Digital Multimeter
Get Latest Price
FEATURES :
Backlight Display | |
Max. Voltage Between Terminal | |
And Earth Ground | 1000 V DC or 750 rms AC (sine) |
Fuse protection | mA, mA; F 400 mA/250V |
Power supply | 9 V battery, NEDA 1604 or 6F22 |
Display | LCD, 3999 counts max., Updates 2-3/Sec |
Measurement Method | Dual slope integration A/D converter |
Ranging Method | Auto/Manual |
Overrange Indication | “OL” displayed |
Polarity indication | “-” displayed automatically |
Low Battery Indication | “ ” displayed |
Operating Temperature | 0oC to 40oC(32oF to 104oF) |
Storage Temperature | -10oC to 50oC (10oF to 122oF) |
Dimesion | 88 x 192 x 42 mm |
Weight | about 400g (including battery and holster) |
Accessories | Test leads (pair), Battery, Mnaual, Holster, Carrying, case, Tilt Stand |
Additional Information:
- Item Code: 6040
View Complete Details
Mobile Logger Digital Multimeter
Get Latest Price
Features :
- 87000 Stand-alone Data-Logging function (Points at single Display mode)
- 43000 Stand-alone Data-Logging function (Points at Dual Display mode)
- Multiple Data Recording.
- 4 Digit 10,000 counts large easy to read LCD display
- Fast measurements, 5 /sec; Fully Auto-ranging
- Dual Digital display
- 41 segment Analog Bar-graph updates 60/sec
- 0.08% high Basic DCV accuracy
- Optional purchase USB cable & software for Win98/2k/xp/Vista
- Intelligent Auto power off
- Data Hold
- Relative Zero mode
- Audible & Visible Beep jackTM Input warning against improper plug in
- AC, AC+DC True RMS conversion
- Record Max/Min readings, Auto-ranging
- Crest (Peak Hold) Max/Min readings, Auto-ranging
- Non-contact EF-Detection (NCV)
- Probe-contact EF-Detection for more precise indication of Live
- AutocheckTM feature (Automatic DCV, ACV & Ohms selection)
- Lo-Z Volts to drain Ghost voltages (AutocheckTM feature)
- Back-lighted large easy to read LCD display
- DCV 0.01mV to 1000V
- ACV 0.01mV to 1000V
- AC+DCV 0.01mV to 1000V
- DCA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- ACA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- AC+DCA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- Ohms 0.1Ω to 60MΩ
- Conductance 0.01nS to 100nS
- Capacitance 60.00nF to 25mF
- T1 Type-K Temperature readings -50oC to 1000oC
- T2 Dual Type-K Temperature readings -50oC to 1000oC
- Line Level Frequency 5Hz to 200kHz
- Logic Level Frequency 5Hz to 2MHz
- Logic Level Duty Cycle readings 0.1% to 99.99%
- Diode Tester
Safety :
Double insulation per IEC61010-1 2nd Ed.,EN61010-1 2nd Ed., UL61010-1 2nd Ed. & CAN /CSA
C22.2 No. 61010.1-0.92 to Category IV 1000V AC & V DC.
- Transient protection : 12kV (1.2/50µs surge)
- Pollution degree:2
- Measurement Category :CAT IV 1KV.
- E.M.C. : Meets EN61326-1:2006 , EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11
- In an RF field of 3V/m:
- Capacitance function is not specified
- Other function ranges:
- Total Accuracy = Specified Accuracy + 100 digits
- Overload Protections : 1000VDC and VAC rms
- Rugged fire retarded casing with battery access door
- Replaceable protective holster with probe-holders & Tilt-stand
- Optional purchase magnetic hanger
- 1000V (Ohm, Capacitance & all other Functions) Input protection
- 1000V High Breaking Capacity fuses protected on Current inputs
- LVD meets EN61010-1 CAT IV 1kV
Additional Information:
- Item Code: KM-525
View Complete Details
SPECIFICATIONS :
DC voltage : 0.4/4/40/400/600V ± 0.7%
AC voltage : 4/40/400/600V ± 0.8%
DC current : 40/400mA ± 1.2%, 10A ± 2.0%
AC current : 40/400mA ± 1.5%, 10A ± 3.0%
Resistance : 400/4K/ 40K/400K/4M W
± 1.2%, 40M W ± 2.0%
Display : 3999 counts, digit is 14mm high
In conformity with IEC 1010 CAT II 1000V
Auto range
Data Hold
Relative measurement
Back light
Auto power off
Capacitance : 4n/40n/400n/4m/40m/
200mF ± 3.0%
Frequency : 10/100/1K/10K/100KHz ± 2.0%
Continuity test
Duty cycle : 0.1% ~ 99.9% ± 3.0%
ELECTRICAL SPECIFICATIONS :
Temperature : -20C ~ 400C ± 3.0% (0.1C),
400C ~ 1000C ± 3.0% (1OC)
Humidity : 30% ~ 95% RH ± 5.0% RH
View Complete Details
Hand Held Digital Multimeter
Get Latest Price
Features :
DISPLAY | : | 4-4/5 digits 50,000 counts. Selectable stable mode 5-4/5 digits 500,000 counts for DC Voltage, & 6 digits 999,999 counts for Hz. |
POLARITY | : | Automatic |
UPDATE RATE | : | 4-4/5digits fast mode : 5 per second nominal; 5-4/5 digits stable mode : 1.25 per second nominal; 42 Segments Bar Graph : 60 per second max |
LOW BATTERY | : | Below approx. 7V |
OPERATING TEMPERATURE | : | 0oC to 45oC |
RELATIVE HUMIDITY | : | Maximum relative humidity 80% for temperature upto 30°C decreasing linearly to 50% relative humidity at 45°C |
POLLUTION DEGREE | : | 2 |
STORAGE TEMPERATURE | : | -20°C to 60°C, 80% R.H. (With battery removed) |
ALTITUDE | : | Operating below 2000m |
TEMPERATURE COEFFICIENT | : | Nominal 0.1 x (specified accuracy) / oC @ (0oC -- 18oC or 28oC -- 40oC), or otherwise specified. |
SENSING | : | AC, AC+DC True RMS |
POWER SUPPLY | : | Single alkaline 9V battery. |
POWER CONSUMPTION | : | 5mA typical |
APO TIMING | : | Idle for 4.5 minutes |
APO CONSUMPTION | : | 20µA |
DIMENSION | : | 186(L) mm x 87(W) mm x 35.5(H) mm; 198(L) mm x 97(W) mm x 55(H) mm with Holster |
WEIGHT | : | 390 gm, 500 gm with Holster |
SPECIAL FEATURES | : | Record MAX, MIN, MAX-MIN reading. Crest (Instantaneous Peak hold) MAX, MIN, MAX-MIN reading. Relative zero mode. 500,000 counts high resolution stable reading mode. Backlighted display dBm readings. %4-20mA loop current readings. High noise rejection filtered Line Level Frequency mode. Data Hold. Audible & Visible input warning. |
STANDARD ACCESSORIES | : | Test leads (pair), holster, battery installed, user’s manual, carrying case. |
OPTIONAL ACCESSORIES | : | PC interface Kit (RS232 optical adapter cable + RS232 Software floppies) |
Safety : The meter is protected, against the users, by double insulation per EN61010-1 and
IEC61010-1 2nd Edition (2001) to CAT III 1000V & CAT IV 600V. The meter also meets UL3111-1 (1994)* and CSA C22.2 No. 1010-1-92* to CAT III 1000V.
Category IV safety standard was first released in IEC61010-1 2nd Edition in year 2001, and was yet an UL published standard at the time this catalog was written.
E.M.C. : Meets EN61326(1997, 1998/A1), EN61000-4-2(1995) and EN61000-4-3(1996)
OVERLOAD PROTECTIONS :
- µA & mA: 0.63A/500V, IR 100kA, F fuse
- A :12.5A/500V, IR 10kA, F fuse
- V : 1050 Vrms, 1450 V peak
- mV, & Others : 600 VDC/VAC rms.
TRANSIENT PROTECTION : 8kV lightning surge (1.2/50µs)
Additional Information:
- Item Code: KM-857
View Complete Details
Dual Display TRMS Digital Multimeter
Get Latest Price
Features :
- Digit 10,000 counts large easy to read LCD display
- Fast measurements, 5 /sec; Fully Auto-ranging
- Dual Digital display
- 41 segment Analog Bar-graph updates 60/sec
- 0.08% High Basic DCV accuracy
- Optional purchase USB cable & software for Win98/2k/xp/Vista
- Intelligent Auto power off
- Data HOLD
- Relative Zero mode
- Audible & Visible Beep jackTM Input warning against Improper plug in
- AC, AC+DC True RMS conversion
- Record Max/Min readings, Auto-ranging
- Crest (Peak Hold) Max/Min readings, Auto-ranging
- Non-Contact EF-Detection (NCV)
- Probe-Contact EF-Detection for more precise indication of live
- AutocheckTM feature (Automatic DCV, ACV & Ohms selection)
- Lo-Z Volts to drain Ghost voltages (AutocheckTM feature)
- Back-lighted large easy to read LCD display
- dBm readings, 20 selectable impedance values
- DCV 0.01mV to 1000V
- ACV 0.01mV to 1000V
- AC+DCV 0.01mV to 1000V
- DCA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- ACA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- AC+DCA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- Ohms 0.1Ω to 60MΩ
- Conductance 0.01nS to 100nS
- Capacitance 60.00nF to 25mF
- T1 Type-K Temperature readings - 50oC to 1000oC
- T2 Dual Type-K Temperature readings - 50oC to 1000oC
- Line Level Frequency 5Hz to 200kHz
- Logic Level Frequency 5Hz to 2MHz
- Logic Level Duty Cycle readings 0.1% to 99.99%
- Diode Tester
Safety :
- Double insulation per IEC61010-1 2nd Ed.,EN61010-1 2nd Ed., UL61010-1 2nd Ed. & CAN /CSA C22.2 No. 61010.1-0.92 to Category IV 1000V AC & V DC.
- Transient protection : 12kV (1.2/50µs surge)
- Pollution degree:2
- Measurement Catagory :CAT IV 1KV.
- E.M.C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, En61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)
- In an RF field of 3V/m:
- Capacitance function is not specified
- Other function ranges:
- Total Accuracy = Specified Accuracy + 100 digits
- Overload Protections : 600VDC and VAC rms
• Replaceable protective holster with probe-holders & Tilt-stand
• Optional purchase magnetic hanger
• 600V (Ohm, Capacitance & all other Functions) Input protection
• 600V High Breaking Capacity fuses protected on Current inputs
• LVD meets EN61010-1 CAT IV 1kV
Additional Information:
- Item Code: KM-829
View Complete Details
Digital Multimeter with EF-Detection & Computer Interface
Get Latest Price
Special Features :
- Autocheck V
- EF-Detection (NCV)
- Crest Mode (Peak Hold), Data Hold function
- Average Sensing (Model KM 255)
- TRUE RMS (Model KM 257)
- 24 Segments Analog Bar-graph
Features :
- Backlight LCD Display
- Autoranging Relative Zero Mode
- Auto-ranging MAX/MIN record
- Wrong Input (test lead) warning detection (w. r. t. switch position)
- Auto Power Off
- Low Battery Indication
- PC interface (optional)
- Diode & Continuity Test
General Specifications :
- Display : 3-5/6 digits 6000 counts LCD display
- Update Rate : Fast Data : 5 per second nominal 24 Segments Analog Bar-graph : 40/second
- Operating Temperature : 0°C to 40°C,at <70% R.H.
- Relative Humidity : Maximum relative humidity 80% for temperature upto 31°C decreasing linearly to 50% relative humidity at 40°C
- Storage Temperature: -20°C to 60°C, <80% R.H. With battery removed from meter
- Altitude : 2000m
- Pollution Degree : 2
- Temperature Coefficient : nominal 0.15 x (specified accuracy)/°C @ (0°C~18°C or 28°C~40°C), or otherwise specified
- Low battery : Below approx. 2.3V
- Power Consumption : 3.5mA
- APO Consumption : 10µA typical
- APO Timing : Idle for 34 minutes
- Power Supply : 1.5V AAA battery x 2
- Dimension : 161(L) X 80(W) X 50(H) mm
- Weight : Approx. 340 gm ( with Holster)
Safety :
- Double insulation per IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed. & CAN/CSA C22.2 No. 61010.1-0.92 to Category II 1000V, CAT III 600V and CAT IV 300V AC & DC
- E. M. C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) In an RF field of 3V/m : Capacitance function is not specified. Other function ranges : Total Accuracy = Specified Accuracy + 100 digits (Performance above 3V/m is not specified)
- Transient Protection : 6.5kV lightning surge (1.2/50µs)
Accessories : Test leads pair, Carrying Case, Batteries installed, User's Manual & Banana plug K-Type Thermocouple
Optional Accessories : PC interface kit, Magnetic Hanger, Banana plug to K-Type socket plug adaptor
View Complete Details
Digital TRMS Multimeter Mobile Logger
Get Latest Price
On Screen Date- logging capability 43000 points display with selectable sampling interval 0.05, 1, 20, 40, 60, 120, 240, & 480 seconds
Special Features :
- Data Logging + On screen Data item review
- 52 Segment Bar Graph
- Splash Proof construction
- Auto Leads Resistance Calibration
- Sleep & Log mode to largely extend battery life.
- Logged Max’s & Min’s turning points on screen recall
Features :
- Basic Accuracy 0.08%
- RS232 PC interface
- Fully Auto-Ranging
- Fast Measurement 5/Sec
- Backlight Display & Data Hold
- Low Battery Indication
- Diode & Continuity Test
- Auto power off
Safety :
- Double insulation per EN61010-1, UL3111-1,
CSA C22.2 No.1010-1, & IEC1010-1 CAT III for
1000V DC & AC, and CAT IV for 600V DC & AC - Transient Protection : 8 kV (1.2/50μS surge)
- Terminals (to COM) Measurement Category :
V : Category III 1000V AC & DC &
CAT IV 600V AC & DC
A/mAmA: Category III & CAT IV 500V AC &
300V DC - Overload Protection :
mA & mA : 0.63A/500V, IR 200kA , F Fuse
A : 12.5A/500V, IR 20kA, F Fuse
V : 1050Vrms, 1450Vpeak
mV, W & Others : 600V DC / V AC rms - A input 240V HBC fuse protected
- 600V input protection
- Fire Retarded Case & Protective Holster
- EMC meets EN55022/A1 class B, EN50082-1,
IEC801-2, & IEC801-3 - LVD meets EN61010-1 CAT II 1kV AC / DC &
CAT III 600V AC / DC
General Specifications :
- Sensing : True RMS
Frequency Bandwidth 20kHz (V) & 1kHz (A) - Display : 3-4/5 digits 5000 counts LCD display
- Update Rate :
Digital Data : 5 per second nominal
52 Segments Bargraph : 60per second nominal - Low Battery : Below approx. 7V
- Operating Temperature : 0°C to 45°C, 0-80% R.H.;
35°C to 50°C, 0-70% R.H. - Storage Temperature : -20°C to 60°C, 80% R.H.
(With battery removed) - Temperature Coefficient : nominal 0.15 x (specified
accuracy)/°C @ (0°C - 18°C or 28°C - 50°C); or
otherwise specified. - Apo Timing : Idle for 17 minute
- Power Consumption : 2.7mA typical
- Power Supply : Single alkaline 9V battery
- Dimension : 186(L) X 87(W) X 35.5(H) mm
198(L) X 97(W) X 55(H)mm with holster - Weight : Approx.340 gm;
Approx. 430gm with Holster
Accessoreis : Test leads (pair), Holster, Battery installed, User's Manual, Banana plug K-Type Thermocouple
Optional Accessories :
- PC interface Kit, (RS232 optical adapter cable+software CD), Bkb32 banana plugs to K-Type socket plug Adapter
- Model - KM 511 / KM 515
- Current Clamp CA300
- Current Clamp Adaptor CA500, CA1000, CA2000,
- High Voltage Probe PD-28
Additional Information:
- Item Code: KM-515
View Complete Details
Dual Display Digital Multimeter with VFD Feature
Get Latest Price
Special Features :
- VFD-V & VFD-Hz in Dual Display
- 5msCREST-MAX capture mode (Peak Hold)
- Autoranging Relative -Zero mode
- Display Hold
- EF-Detection (NCV)
- Beep-Jack input warning
- Hz Line Level Frequency
- Hz Logic Level Frequency
- Diode Test
- Continuity Test
GENERAL SPECIFICATIONS :
- Sensing : Average sensing
- Display : 3-5/6 digits 6000 counts + 3 digits 999 counts dual LCD display
- Update Rate : 5 per second nominal
- Polarity : Automatic
- Low Battery : Below approx 2.4V
- Operating Temperature : 0°C to 40°C
- Relative Humidity : Maximum 80% R. H. For temperature upto 31oC decreasing linearly to
50% Relative Humidity at 40°C - Altitude : Operating below 2000m
- Storage Temperature : -20°C to 60°C, < 80% R.H. (With battery removed)
- Temperature Coefficient : nominal 0.15 x (specified accuracy) / °C @ (0°C--18°C or 28°C--40°C),
or otherwise specified - Power supply : Standard 1.5V AAA Battery x 2.
- Power Consumption : 5.4mA typical
- APO Timing : Idle for 34 minutes
- APO Consumption : 10µA typical
- Dimension : 186(L) x 87(W) x 35.5(H) mm ; 198(L) x 97(W) x 55.5(H) mm with Holster.
- Weight : Approx. 340 gms; 430gm with holster
SAFETY :
- Double insulation per IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed., & CAN/CSA C22.2 No.
61010.1-0.92 to Category II 1000V, CAT III 600V & CAT IV 300V AC & DC. - Transient Protection : 6kV (1.2/50ms surge)
- Terminals (to COM) Measurement Category :
V : CAT II 1000V, CAT III 600V & CAT IV 300V AC & DC.
µAmA : CAT III 500Vac & 300Vdc.
A : CAT III 600Vac & 300Vdc. - EMC : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)
In an RF field of 3V/m :
Capacitance function is not specified
Other function ranges : Total Accuracy = Specified Accuracy + 100 dgts
Performance above 3V/m is not specified. - Overload Protection :
µA & mA : 0.63A/500Vac, IR 50kA or better, F Fuse
A : 10A/600Vac, IR 100kA or better, F Fuse
V : 1050 Vrms, 1450 Vpeak
ACCESSORIES : Test lead (pair), Holster, Battery installed, User Manual & Carrying case
OPTIONAL ACCESSORIES : Current Clamp CA300, Current Clamp Adaptor CA500, CA1000, CA2000, High Voltage Probe PD-28
Additional Information:
- Item Code: KM-711
View Complete Details
Digital Multimeter with Analog Bar Graph
Get Latest Price
features :
display | : | 3-4/5 digits 5000 counts lcd display |
update rate | : | fast data : 5 / second nominal; ultra-high-speed 52 segment bar-graph : 60/second |
sensing | : | average sensing, true rms (for model-5040-t) |
operating temperature | : | 0oc to 45oc |
relative humidity | : | maximum relative humidity 80% for temperature upto 31oc decreasing linearly to 50% relative humidity at 45oc |
storage temperature | : | -20oc to 60oc, 80% r. H. (with battery removed) |
pollution degree | : | 2 |
altitude | : | operating below 2000m |
temperature coefficient | : | nominal 0. 15 x (specified accuracy)/ oc @ (0oc to 18oc or 28oc to 45oc), or otherwise specified. |
power supply | : | single 9v battery. |
power consumption | : | 2. 6ma typical |
low battery | : | below approx. 7v |
apo timing | : | idle for 17 minutes. |
accessories | : | test leads (pair), holster, battery (installed), user’s manual, carrying case |
optional accessories | : | pc interface kit (rs232 optical adapter cable + software cd), rs232-usb convertor |
weight | : | 340gm, 430gm with holster. |
dimension | : | 186(l)mm x 87(w)mm x 35. 5(h)mm, 198(l)mm x 97(w)mm x 55(h)mm with holster |
special features | : | data hold, range-hold, backlighted display, optical isolated rs232 pc-interface capabilities. |
safety : the meter is protected, against the users, by double insulation per iec61010-1 2nd edition (2001) to cat iii 1000v & cat iv 600v. The meter also meets ul3111-1(1994)* and csa c22. 2 no. 1010-1-92* to cat iii 1000v
Additional Information:
- Item Code: 5040
View Complete Details
54/5 Digits Hand Held Digital Multimeter
Get Latest Price
display | : | 4-4/5 digits 50,000 counts. Selectable stable mode 5-4/5 digits 500,000 counts for dc voltage, 6 digits 999,999 counts for hz |
polarity | : | automatic |
update rate | : | 4-4/5 digits fast mode : 5 per second nominal;5-4/5 digits stable mode : 1. 25 per second nominal; 42 segments bar graph : 60 per second max. |
low battery | : | below approx. 7v |
operating temperature | : | 0oc to 45oc |
relative humidity | : | maximum relative humidity 80% r. H. For temperature upto 31oc decreasing linearly to 50% relative humidity at 45oc |
pollution degree | : | 2 |
storage temperature | : | -20oc to 60oc, < 80% r. H. (with battery removed) |
altitude | : | operating below 2000m |
temperature coefficient | : | nominal 0. 1 x (specified accuracy) / oc @ (0oc -- 18oc or 28oc -- 40oc), or otherwise specified. |
sensing | : | ac, ac + dc true rms |
power supply | : | single alkaline 9v battery. |
power consumption | : | 5ma typical |
apo timing | : | idle for 4. 5 minutes |
apo consumption | : | 20µa |
dimension | : | 186(l) mm x 87(w) mm x 35. 5(h) mm; 198(l) mm x 97(w) mm x 55(h) mm with holster |
weight | : | 390 gm, 500 gm with holster |
special features | : | record max, min, max-min readings. Crest (instantaneous pead hold) max, min, max-min readings. Relative zero mode. 500,000 counts high resolution stable reading mode. Backlighted display dbm readings. T1-t2 differential temperature readings %4-20 ma loop current readings. High noise rejection filtered line level frequency mode. Data hold. Audible & visible input warning. |
standard accessories | : | test leads (pair), holster, battery installed, user’s manual, k-type thermocouple x 1. |
optional accessories | : | pc interface kit (rs232 optical adapter cable + rs232 software cd) , pins to type-k socket plug adapter. |
safety :
the meter is protected, against the users, by double insulation per en61010-1 and iec61010-1 2nd edition (2001) to cat iii 1000v & cat iv 600v. The meter also meets ul3111-1 (1994) * and csa c22. 2 no. 1010-1-92* to cat iii 1000v
e. M. C. | : | meets en61326(1997, 1998/a1), en61000-4-2(1995) and |
overload protections | : | µa & ma : 1a/1kv(or 0. 44a/1kv)ir 10ka, ffuse |
transient protection | : | 8kv lightning surge (1. 2/50µs) |
View Complete Details
Voltage Tester
Get Latest Price
Features :
Display | : | 3 digits 1000 counts |
Update Rate | : | 5 per second nominal |
Backlight display | ||
AC-Detection Shaker | ||
Bi-color LED hazardous live warning (at > 70VDC / 33VAC) | ||
RCD Leakage Load for 230VAC / 30mA RCD Circuit Breakers | ||
Continuity | : | Audible Beeper & Visible LED indications |
Automatic DCV, ACV & Continuity Selection. | ||
Non-contact EF-Detection (NCV) | ||
Probe - Contact EF-Detection for more precise indication of live. | ||
Overload Alert warning (1000V LED flashes when > 1000VAC/DC) | ||
Operating Temperature | : | -10oC ~ 55oC |
Relative Humidity | : | 20% ~ 96% |
Altitude | : | Operating below 2000m |
Storage Temperature | : | -10oC ~ 55oC, 20% ~ 96% R.H. (With battery removed) |
Temperature Coefficient | : | Nominal 0.15 x (specified accuracy) / oC @ (-10oC ~ 18oC or 28oC ~ 55oC), or otherwise specified. |
Sensing | : | Average sensing |
Low Battery | : | Below approx. 2.4V; Below approx. 2.6V with shaker ON |
Power Supply | : | Standard 1.5V AAA size battery x 2; or 1.5V AAA size alkaline battery x 2 |
APO Timing | : | Idle for 15 seconds |
Power Consumption (typical) | 3mA at Power-on ready; 25mA at 1000VAC full LED indication. 75mA at 1000VAC with shaker ON. | |
APO Consumption (typical) | : | 10 A |
Dimension | : | 178(L) x 57(W) x 34(H)mm |
Weight | : | Approx. 174gm |
Special Features | : | High input impedance, Indicator Self-test, Auto-Hold, Overload-Alert warning, EF-Detection, AC-Detection Shaker, Bi-color LED Hazardous Live warning, and RCD Trip test. |
Accessories | : | Detachable (Black) Test lead, Screw-on Stationary (Red) Probe, 2 Screw-on 4mm Tip Accessories, batteries installed and User’s manual, Carrying Case |
Safety : Meets EN61243 voltage class B, EN61010-1 and IEC61010-1 2nd Edition (2001) to CAT III 1000V & CAT IV 600V
- Type of Protection : IP65 - water and Dust Resistant.
- Pollution Degree : 2
- Transient Protection : 8kV lightning surge (1.2/50s)
- Measurement Category : CAT III 1000V & CAT IV 600V AC & DC
Additional Information:
- Item Code: KM-69
View Complete Details