| 3 Phase Power Clamp On MeterItem Code: 2709 | FEATURES |
| | Display | : | Voltage Function : 6000 counts LCD display, Power, Ohm & Hz functions : 9999 counts LCD display. ACA clamp-on function : 4000 counts LCD display. | | Update Rate | : | Power function : 2 per second nominal Voltage, ACA clamp-on & Ohm functions : 2 per second nominal Hz function : 1 per second nominal | | Polarity | : | Automatic | | Low Battery | : | Below approx 2.4V | | Operating Temperature | : | 0oC to 40oC | | Relative Humidity | : | Maximum relative humidity 80% for temperature upto 31oC decreasing linearly to 50% relative humidity at 40oC | | Altitude | : | Operating below 2000m | | Storage Temperature | : | -20°C to 60°C, < 80% R.H. (With battery removed) | | Temperature Coefficient | : | nominal 0.15x (specified accuracy) /°C @ (0°C -18°C or 28°C - 40°C), or otherwise specified | | Sensing | : | True RMS sensing | | Power supply | : | Standard 1.5V AAA Battery x 2. | | Power Consumption | : | Voltage, ACA, Hz & Power functions : 11mA typical Ohm function : 5.5mA typical | | APO Timing | : | Idle for 30 minutes | | APO Consumption | : | 4µA typical | | Dimension | : | 224(L) x 78(W) x 40(H) mm | | Weight | : | approx. 224 gms | | Jaw opening & Conductor diameter | : | 45mm max | | Special features | : | Backlight display, AutoVATM (Auto Selection on ACV, DCV or ACA functions); selectable Power parameters of KW, KVAR & KVA with Total Power Factor in dual-display; Total harmonic distortion THD%-F in dual-display; kWHr Recording; Display Hold; PEAK-rms HOLD; PC-Comm computer interface capabilities | | Accessories | : | Test leads (pair), batteries installed, user’s manual & soft carrying case | | Optional Accessories | : | PC interface kit | | SAFETY | | Meets IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003) | | Measurement Category | : | CATIII 600Volts AC & DC | | Transient Protection | : | 6.5kV (1.2/50µs Surge) | | Pollution degree | : | 2 | | E. M. C. | : | Meets EN61326(1997, 1998/A1), EN61000-4-2 (1995,2000/A2), and EN61000-4-3(2002) | | In an RF field of 3V/m | : | Total Accuracy = specified Accuracy + 50 digits Performance above 3V/m is not specified | | Overload Protections | : | ACA Clamp-on jaws : AC 1000A rms continuous + & COM terminals : 600VDC/VAC rms | | |
3 Phase Trms Power Clamp On MeterItem Code: KM-357 MODEL KM 357 | SPECIAL FEATURES : |
| | • Backlight display | | • AutoVATM (Auto Selection on ACV, DCV or ACA functions); | | • Selectable Power parameters of W, VAR & VA with Total Power Factor in dual-display. | | • kWHr Recording | | • Display Hold & PEAK-rms HOLD | | • PC-Comm computer interface capabilities | | | | GENERAL SPECIFICATIONS : | | * Display : Voltage Function : 6000 counts LCD display Power, Ohm & Hz functions : 9999 counts LCD display ACA clamp-on function : 4000 counts LCD display | | * Update Rate : Power function : 2 per second nominal Voltage, ACA clamp-on & Ohm functions : 2 per second nominal Hz function : 1 per second nominal | | * Jaw opening & Conductor diameter : 26mm max | | * Sensing : True RMS sensing | | * Polarity : Automatic | | * Low Battery : Below approx 2.4V | | * Operating Temperature : 0oC to 40oC | | * Relative Humidity : Maximum relative humidity 80% for temperature upto 31oC decreasing linearly to 50% relative humidity at 40oC | | * Altitude : Operating below 2000m | | * Storage Temperature : -20oC to 60oC, < 80% R.H. (With battery removed) | | * Temperature Coefficient : nominal 0.15 x (specified accuracy) / 0C @ (0oC-18oC or 28oC-40oC), or otherwise specified | | * Power supply : Standard 1.5V AAA Battery x 2. | | * Power Consumption : Voltage, ACA, Hz & Power functions : 11mA typical Ohm function : 5.5mA typical | | * APO Timing : Idle for 30 minutes | | * APO Consumption : 4mA typical | | * Dimension : 189(L) x 78(W) x 40(H) mm | | * Weight : Approx. 192 gms | | | | SAFETY : | | • Meets IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed., IEC61010-2-032, EN61010-2-032, UL61010B-2-032. | | • E. M. C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-7, EN61000-4-8, EN61000-4-11) In an RF field of 3V/m : Total Accuracy = Specified Accuracy + 50 digits Performance above 3V/m is not specified | | • Measurement Category : CAT III 600Volts AC & DC | | • Transient Protection : 6.5kV (1.2/50mS surge) | | • Pollution degree : 2 | | • Overload Protections : ACA Clamp-on jaws : AC 600A rms continuous + & COM terminals(all functions) : 600VDC/VAC rms | | | | ACCESSORIES : | | • Test leads (pair), Battery installed, User's Manual, Carrying Case | | | | OPTIONAL ACCESSORIES : | | • PC interface Kit, (including BUA-2303 USB-to-Serial adaptor, BA-1XX optical adapter back, BC-100R cable & Bs Software CD) | | | |
| Power Clamp Meter Model - 2745 Power Clamp Meter Our experts quality controllers stringently test this range of 3 Phase (TRMS) Power Clamp Meters with Harmonics Level & Inrush Current Measurement on various parameters as laid down by the industry regulatory bodies. These stringent tests ensure that only superior quality products are delivered to our valued clients. MODEL - 2745 POWER CLAMP METER | FEATURES |
| * Power measurement of Active power (KW), Reactive power (KVAR), Apparent power (KVA), Power Factor (PF),PF for 3??4W, 3??3W, 1??2W, 1??3W. * Harmonic measurement(Level & Percentage) * PF (Cos??) for 3??4W, 3??3W, 1??2W, 1??3W. * Triple display : KW, V, A easy to read,9999 counts. * Records each Phase parameters of V,A,KW, KVA, KVAR, PF, Hz, total 25 parameters. * AC current up to 1000A, AC voltage up to 600V. * INRUSH (100mS), HOLD and PEAK functions. * MAX and MIN recorded functions. * Balanced load system function. * Max,conductor diameter : 46.5mm. * Auto power off (10 mins). * EN 61010-1 Approval Over-Voltage Category III 600V * • Power : 9 V Battery *• Accessories: Carrying case, Test leads , manual | | |
Single Phase Power Clamp MeterItem Code: KM2740 | FEATURES |
| * Light Weight & Stylish ; 45mm Large jaws opening * 1000A AC Clamp-on + Multimeter ranges * 600V AC/DC input protection on all functions * AC True RMS voltage and current functions * + Dual display Power Factor (PF) & A-Lags-V Phase-Shift indication. * Automatic selection of DCV, ACV & ACA measurements (Auto V.A) * Fast PEAK-rms Hold (65ms to 90%) for In-rush ACA & ACV readings * PC-Comm (optical isolated PC interface capability) * Software kit for Win 95/98/ME/2000/XP (optional purchase) * Data HOLD * 5Hz ~ 500Hz line Frequency measurements * DCV & ACV 0.1V to 600.0V * ACA 0.01A to 1000A non-invasive current measurements * Ohm 0.1??? to 999.9??? * Fast Audible Continuity * Battery cover with Probe holders * Rugged Fire-retarded casing; Soft carrying pouch * Transient Protection 6KV 1.2/50µs lightning Surge. * LVD EN61010-2-032 CAT III 600V * EMC EN61326(1997/1998A1) / EN61000-4-2(1995/2000A2) / EN61000-4-3(2002) | | | |
| Power Clamp Meter (TRMS) | FEATURES |
| * Display : Voltage Function : 6000 counts LCD display Power, Ohm & Hz functions : 9999 counts LCD display ACA clamp-on function : 4000 counts LCD display * Update Rate : Power function : 2 per second nominal Voltage, ACA clamp-on & Ohm functions : 2 per second nominal Hz function : 1 per second nominal * Polarity : Automatic * Low Battery : Below approx 2.4V * Operating Temperature : 0°C to 40°C * Relative Humidity : Maximum relative humidity 80% for temperature upto 31°C decreasing linearly to 50% relative humidity at 40°C * Altitude : Operating below 2000m * Storage Temperature : -20°C to 60°C, < 80% R.H. (With battery removed) * Temperature Coefficient : nominal 0.15x (specified accuracy) / °C @ (0°C -18°C or 28°C - 40°C), or otherwise specified * Sensing : True RMS sensing * Power supply : Standard 1.5V AAA Battery x 2. * Power Consumption : Voltage, ACA, Hz & Power functions : 11mA typical * Ohm function : 5.5mA typical * APO Timing : Idle for 30 minutes * APO Consumption : 4mA typical * Dimension : 224(L) x 78(W) x 40(H) mm * Weight : approx. 224 gms. * Jaw opening & Conductor diameter : 45mm max * Special features : Backlight display, AutoVATM (Auto Selection on ACV, DCV or ACA functions); selectable Power parameters of KW, KVAR & KVA with Total Power Factor in dual-display; Display Hold; PEAK-rms HOLD; PC-Comm computer interface capabilities * Accessories : Test leads (pair), batteries installed, user’s manual & soft carrying case, banana plug type- K therocouple. * Optional Accessories : PC interface kit (RS232 optional adaptor cable + RS232 software CD)
| SAFETY | | | * Meets IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003) * Measurement Category : CAT III 600Volts AC & DC * Transient Protection : 6.5kV (1.2/50µs surge) * Pollution degree : 2 * E. M. C. : Meets EN61326(1997, 1998/A1), EN61000-4-2 (1995,2000/A2), and EN61000-4-3(2002) * In an RF field of 3V/m : Total Accuracy = specified Accuracy + 50 digits * Performance above 3V/m is not specified * Overload Protections : ACA Clamp-on jaws : AC 1000A rms continuous + & COM terminals : 600VDC/VAC rms |
| |
|