KUSAM  ELECTRICAL INDUSTRIES LTD.

Products We Offer

Home Profile Contact Us Enquiry


Showcase

Showcase

View all our products / services as a slide show.


Clamp Meter

Share: Facebook TwitterStumble
We offer Clamp Meter.


3 Phase Power Clamp On Meter
Large View

3 Phase Power Clamp On Meter

Item Code: 2709
    FEATURES

Display : Voltage Function : 6000 counts LCD display,
Power, Ohm & Hz functions : 9999 counts LCD display.
ACA clamp-on function : 4000 counts LCD display.
Update Rate : Power function : 2 per second nominal
Voltage, ACA clamp-on & Ohm functions : 2 per second nominal Hz function : 1 per second nominal
Polarity : Automatic
Low Battery : Below approx 2.4V
Operating Temperature : 0oC to 40oC
Relative Humidity : Maximum relative humidity 80% for temperature
upto 31oC decreasing linearly to 50% relative humidity at 40oC
Altitude : Operating below 2000m
Storage Temperature : -20°C to 60°C, < 80% R.H. (With battery removed)
Temperature Coefficient : nominal 0.15x (specified accuracy) /°C
@ (0°C -18°C or 28°C - 40°C), or otherwise specified
Sensing : True RMS sensing
Power supply : Standard 1.5V AAA Battery x 2.
Power Consumption : Voltage, ACA, Hz &
Power functions : 11mA typical
Ohm function : 5.5mA typical
APO Timing : Idle for 30 minutes
APO Consumption : 4µA typical
Dimension : 224(L) x 78(W) x 40(H) mm
Weight : approx. 224 gms
Jaw opening & Conductor diameter : 45mm max
Special features : Backlight display, AutoVATM (Auto Selection on ACV, DCV or ACA functions); selectable Power parameters of KW, KVAR & KVA with Total Power Factor in dual-display; Total harmonic distortion THD%-F in dual-display; kWHr Recording; Display Hold; PEAK-rms HOLD; PC-Comm computer interface capabilities
Accessories : Test leads (pair), batteries installed, user’s manual & soft carrying case
Optional Accessories : PC interface kit
SAFETY
Meets IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003)
Measurement Category : CATIII 600Volts AC & DC
Transient Protection : 6.5kV (1.2/50µs Surge)
Pollution degree : 2
E. M. C. : Meets EN61326(1997, 1998/A1), EN61000-4-2 (1995,2000/A2), and EN61000-4-3(2002)
In an RF field of 3V/m : Total Accuracy = specified Accuracy + 50 digits
Performance above 3V/m is not specified
Overload Protections : ACA Clamp-on jaws : AC 1000A rms continuous
+ & COM terminals : 600VDC/VAC rms

3 Phase Trms Power Clamp On Meter

Item Code: KM-357
 MODEL KM 357
  SPECIAL FEATURES :

• Backlight display
• AutoVATM (Auto Selection on ACV, DCV or ACA functions);
• Selectable Power parameters of W, VAR & VA with Total Power Factor in dual-display.
• kWHr Recording
• Display Hold & PEAK-rms HOLD
• PC-Comm computer interface capabilities
 
GENERAL SPECIFICATIONS :
* Display : Voltage Function : 6000 counts LCD display Power, Ohm & Hz functions : 9999 counts LCD display ACA clamp-on function : 4000 counts LCD display
* Update Rate : Power function : 2 per second nominal Voltage, ACA clamp-on & Ohm functions : 2 per second nominal Hz function : 1 per second nominal
* Jaw opening & Conductor diameter : 26mm max
* Sensing : True RMS sensing
* Polarity : Automatic
* Low Battery : Below approx 2.4V
* Operating Temperature : 0oC to 40oC
* Relative Humidity : Maximum relative humidity 80% for temperature upto 31oC decreasing linearly to 50% relative humidity at 40oC
* Altitude : Operating below 2000m
* Storage Temperature : -20oC to 60oC, < 80% R.H. (With battery removed)
* Temperature Coefficient : nominal 0.15 x (specified accuracy) / 0C @ (0oC-18oC or 28oC-40oC), or otherwise specified
* Power supply : Standard 1.5V AAA Battery x 2.
* Power Consumption : Voltage, ACA, Hz & Power functions : 11mA typical Ohm function : 5.5mA typical
* APO Timing : Idle for 30 minutes
* APO Consumption : 4mA typical
* Dimension : 189(L) x 78(W) x 40(H) mm
* Weight : Approx. 192 gms
 
SAFETY :
• Meets IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed., IEC61010-2-032, EN61010-2-032, UL61010B-2-032.
• E. M. C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-7, EN61000-4-8, EN61000-4-11) In an RF field of 3V/m : Total Accuracy = Specified Accuracy + 50 digits Performance above 3V/m is not specified
• Measurement Category : CAT III 600Volts AC & DC
• Transient Protection : 6.5kV (1.2/50mS surge)
• Pollution degree : 2
• Overload Protections : ACA Clamp-on jaws : AC 600A rms continuous + & COM terminals(all functions) : 600VDC/VAC rms
 
ACCESSORIES :
• Test leads (pair), Battery installed, User's Manual, Carrying Case
 
OPTIONAL ACCESSORIES :
• PC interface Kit, (including BUA-2303 USB-to-Serial adaptor, BA-1XX optical adapter back, BC-100R cable & Bs Software CD)
3 Phase Trms Power Clamp On Meter
Power Clamp Meter
Large View

Power Clamp Meter

Model - 2745 Power Clamp Meter

 

Our experts quality controllers stringently test this range of 3 Phase (TRMS) Power Clamp Meters with Harmonics Level & Inrush Current Measurement on various parameters as laid down by the industry regulatory bodies. These stringent tests ensure that only superior quality products are delivered to our valued clients.

   
  MODEL - 2745 POWER CLAMP METER

    FEATURES

* Power measurement of Active power (KW), Reactive power (KVAR), Apparent power (KVA), Power       Factor (PF),PF for 3??4W, 3??3W, 1??2W, 1??3W.
* Harmonic measurement(Level & Percentage)
* PF (Cos??) for 3??4W, 3??3W, 1??2W, 1??3W.
* Triple display : KW, V, A easy to read,9999 counts.
* Records each Phase parameters of V,A,KW, KVA, KVAR, PF, Hz, total 25 parameters.
* AC current up to 1000A, AC voltage up to 600V.
* INRUSH (100mS), HOLD and PEAK functions.
* MAX and MIN recorded functions.
* Balanced load system function.
* Max,conductor diameter : 46.5mm.
* Auto power off (10 mins).
* EN 61010-1 Approval Over-Voltage Category III 600V
* • Power : 9 V Battery
*• Accessories: Carrying case, Test leads , manual

Single Phase Power Clamp Meter

Item Code: KM2740
FEATURES

* Light Weight & Stylish ; 45mm Large jaws opening
* 1000A AC Clamp-on + Multimeter ranges
* 600V AC/DC input protection on all functions
* AC True RMS voltage and current functions
* + Dual display Power Factor (PF) & A-Lags-V Phase-Shift indication.
* Automatic selection of DCV, ACV & ACA measurements (Auto V.A)
* Fast PEAK-rms Hold (65ms to 90%) for In-rush ACA & ACV readings
* PC-Comm (optical isolated PC interface capability)
* Software kit for Win 95/98/ME/2000/XP (optional purchase)
* Data HOLD
* 5Hz ~ 500Hz line Frequency measurements
* DCV & ACV 0.1V to 600.0V
* ACA 0.01A to 1000A non-invasive current measurements
* Ohm 0.1??? to 999.9???
* Fast Audible Continuity
* Battery cover with Probe holders
* Rugged Fire-retarded casing; Soft carrying pouch
* Transient Protection 6KV 1.2/50µs lightning Surge.
* LVD EN61010-2-032 CAT III 600V
* EMC EN61326(1997/1998A1) / EN61000-4-2(1995/2000A2) / EN61000-4-3(2002)
Single Phase Power Clamp Meter
Large View
Power Clamp Meter (TRMS)
Large View

Power Clamp Meter (TRMS)

 FEATURES

* Display :
Voltage Function : 6000 counts LCD display
Power, Ohm & Hz functions : 9999 counts LCD display
ACA clamp-on function : 4000 counts LCD display

* Update Rate :
Power function : 2 per second nominal
Voltage, ACA clamp-on & Ohm functions : 2 per second nominal
Hz function : 1 per second nominal

* Polarity : Automatic
* Low Battery : Below approx 2.4V
* Operating Temperature : 0°C to 40°C
* Relative Humidity : Maximum relative humidity 80% for temperature upto 31°C decreasing linearly to 50%       relative humidity at 40°C
* Altitude : Operating below 2000m
* Storage Temperature : -20°C to 60°C, < 80% R.H. (With battery removed)
* Temperature Coefficient : nominal 0.15x (specified accuracy) / °C @ (0°C -18°C or 28°C - 40°C), or    otherwise specified
* Sensing : True RMS sensing
* Power supply : Standard 1.5V AAA Battery x 2.
* Power Consumption : Voltage, ACA, Hz & Power functions : 11mA typical
* Ohm function : 5.5mA typical
* APO Timing : Idle for 30 minutes
* APO Consumption : 4mA typical
* Dimension : 224(L) x 78(W) x 40(H) mm
* Weight : approx. 224 gms.
* Jaw opening & Conductor diameter : 45mm max
* Special features : Backlight display, AutoVATM (Auto Selection on ACV, DCV or ACA functions); selectable    Power parameters of KW, KVAR & KVA with Total Power Factor in dual-display; Display Hold; PEAK-rms    HOLD; PC-Comm computer interface capabilities
* Accessories : Test leads (pair), batteries installed, user’s manual & soft carrying case, banana plug     type- K  therocouple.
* Optional Accessories : PC interface kit (RS232 optional adaptor cable + RS232 software CD)


SAFETY
  * Meets IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003)
* Measurement Category : CAT III 600Volts AC & DC
* Transient Protection : 6.5kV (1.2/50µs surge)
* Pollution degree : 2
* E. M. C. : Meets EN61326(1997, 1998/A1), EN61000-4-2 (1995,2000/A2), and EN61000-4-3(2002)
* In an RF field of 3V/m : Total Accuracy = specified Accuracy + 50 digits
* Performance above 3V/m is not specified
* Overload Protections :
   ACA Clamp-on jaws : AC 1000A rms continuous
  + & COM terminals : 600VDC/VAC rms

Contact us

Mr. Pradeep Goliya
G-17, Bharat Industrial Estate, , Tokershi Jivraj Road
Mumbai, Maharashtra - 400 015, India
Telephone:  +(91)-(22)-24181649/ 24124540/ 24156638

Contact via E-mail

Home | Profile | Products We Offer | Site Navigation | Contact Us | Enquiry
Member IndiaMART.com © KUSAM ELECTRICAL INDUSTRIES LTD.. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry