Showcase
View all our products / services as a slide show.
 |
 |
High Safety UL Approved Digital Clampmeters
|
|
These High Safety UL Approved Digital Clampmeters are expertly designed by our skilled professionals, who possess vast industry experience and knowledge. Besides, we offer these clampmeters with customized solutions to suit the varied specifications and needs of our valuable clients. This range includes the following:
|
| Data Logger (TRMS) Clamp MeterItem Code: KM-135 Item Code: KM-135 Our Data Logger (TRMS) Clamp Meters are widely used in different industrial applications due to their sturdy looks, compact size, reliable operations, easy usage and affordable prices. In addition to this, we strive to enhance to our product range using contemporary machines and tools that are at par with the international quality standards. General Specifications | * Jaw opening & Conductor diameter | 45mm max | | * Display | Voltage functions : 6000 counts LCD display Ohms & Hz functions : 9999 counts LCD display ACA clamp-on function: 4000 counts LCD display | | * Update Rate | Voltage, ACA clamp-on, Ohms & Temperature Functions : 4 per second nominal Hz function: 2 per second nominal | | * Polarity | Automatic | | * Low Battery | Below approx. 2.4V | | * Operating Temperature | 0oC to 40oC | | * Storage Temperatures | -20oC ~ 60oC, <80% R.H. (With battery removed) | | * Power Supply | standard 1.5V AAA Siz battery x 2 | | * Dimension | L224mm x W78mm x H40mm | | * Weight | 224gm approx | | * Accessories | Test leads (pair), batteries installed, user’s manual, & soft carrying pouch PC interface kit banana plug type-K thermocouple etc. | | Hi-Lo Logging Mode :-
A unique feature of this instrument is Hi-Lo logging mode Due to this feature field monitoring is made simpler & affordable. Hi-Lo logging captures the most important surges (Hi) & sages (Lo) on intervals of every one minute. The meter uses its highest update rate to compare & capture the highest & lowest reading on every one minute time interval . | | Safety | | * Safety | Meets IEC61010-2-032(1994), EN61010-2-032(2002), UL3111-2-032(1999).CATEGORY III 600 Volts AC & DC | | * E.M.C | Meets EN61326(1997,1998/A1),EN61000-4-2(1995), and EN61000-4-3(2002) In an RF field Of 3V/m; Total Accuracy = Specified Accuracy + 45digits Performance above 3V/m is not specified | | * Overload Protection | ACA Clamp-on jaws : AC 1000A rms Continuous + & COM terminals (All functions) : 600VDC/VAC rms | | * Transient Protection | 6.5 KV (1.2/50 µs Surge) | | * Pollution Degree | 2 | | * Measurement Catagory | CAT III 600 volts AC & DC | |
Digital Clamp MeterItem Code: 2772 Item Code: 2772 We offer our clients a superior range of Digital Clamp Meters, which is developed using modern technology and machines. Our clients can avail from us customization for this range as per their changing application requirements and specifications. We also ensure that the consignments are dispatched on time to our clients' sites. General Specifications | * Jaw opening & Conductor diameter | 45mmMax | | * Display | 3-5/6 digits 6000 counts | | * Update Rate | 5 Per second nominal | | * Polarity | Automatic | | * Transient Protection | 6.5 KV lightning Surge(1.2/5 µs) | | * Pollution Degree | 2 | | * EMC | Meets 61326 (1997, 1998 / AI), EN 61000 -4-2 (1995) & En 6100-4-3 (1996) In an RF field of 3 V/m : Capacitance function is not specified. Other Function Ranges : Total accuracy = specified accuracy + 45 digits Performance above 3 V/m is not specified. | | * Overload Protection | ACA Clamp on jaws : AC 2000 A rms continuous + & com terminal (all functions) : 600 VDC & VAC rms | | * Low Battery indication | Below approx. 2.4 v | | * APO consumption | 230 µA typical on voltage & current function , 40 µA on other ranges | | * Dimension | 224 (L) X 78 (W) X 40 (H) mm | | * Weight | Approx 220 gms | | * Safety | Meets IEC 61010-2-032 2nd Ed.(2002), UL 3111-2032(1999) | | * Measurement Category | CAT III 600VAC & VDC | | * Power Supply | 2X1.5V AAA batteries | | * Special Features | Autocheck TM (Automatic V & ??? Selection); L0-Z voltage measurements(Can eleminate ghost voltage); EF-detection | | * Accessories | Test leads(pair),batteries installed, users manual, soft carrying Pouch | | |
| Dual LCD Display Digital Clamp MeterItem Code: 2799 Item Code: 2799 We manufacture and supply a large gamut of Dual LCD Display Digital Clamp Meters, which is specially designed using superior grade raw material. This material is sourced from our reputed vendor base, hence, is in compliance with the international quality standards. Moreover, we provide customized solutions with our products range as per the clients' specifications. General Specifications: 3.75 Digits 4000 Count | * Display | 3¾ digits 4000 counts LCD displays | | * Update Rate | 3 per second nominal | | * Polarity | Automatic | | * Low Battery | Below approx. 2.4V | | * Operating Temperature | 0oC to 40oC, <80% R. H. | | * Altitude | Operating below 2000m | | * Storage Temperature | -20°C to 60°C, <80% RH (with battery removed) | | * Temperature Coefficient | Nominal 0.15x (specified accuracy)/oC@(0°C-18oC or 28oC-40oC), or otherwise specified | | * Sensing | Average sensing. | | * Power supply | 1.5V alkaline 4 button batteries. | | * Power Consumption | 2.5 µA typical | | * APO Timing | Idle for 30 minutes | | * APO Consumption | 0.8µA typical. | | * Dimension | 190(L)mm x 63(W)mm x 32(H)mm | | * Weight | 187gm approx. | | * Jaw Opening & Conductor Size | 26mm Max. | | * Accessories | Test leads(pair), Batteries installed, User’s manual & Soft carrying case | | Safety Features | | * Safety | Meets IEC61010-2-032(1994), EN61010-2-032(1995), UL3111-2-032(1999), CAT III 600V AC & DC | | * Transient protection | 6.5KV (1.2/50µS surge) | | * Pollution degree | 2 | | * E.M.C | Meets EN61326 (1997, 1998/A1), EN61000-4-2(1995), and EN61000-4-3(1996) In an RF field of 3V/m : Capacitance function is not specified µA : Total Accuracy = Specified Accuracy + 65 digits Other function rangesTotal Accuracy = Specified Accuracy + 45 digits Performance above 3V/m is not specified | | * Overload protections | ACA Clamp-on jaws : AC 400A rms continuous + µA & COM terminals on all functions : 600VDC/VAC rms | |
Digital Clamp Meter & MultimeterItem Code: KM-111M Item Code: 2772 We offer our clients a superior range of Digital Clamp Meters, which is developed using modern technology and machines. Our clients can avail from us customization for this range as per their changing application requirements and specifications. We also ensure that the consignments are dispatched on time to our clients' sites. | |
| 20kHz ACA Band Width Clamp On Meter & Adapter Output We have been able to export a bulk stock of 20kHz ACA Band Width Clamp On Meter & Adapter Output. This range is mainly designed using premium quality raw material that is in adherence with the international guidelines and policies. Apart from this, we offer customization for our range to meet the rising needs and demands of the clients. | * Display | 3¾ digits 4000 counts LCD displays | | * Update Rate | 3 per second nominal | | * Polarity | Automatic | | * Low Battery | Below approx -2.4 V | | * Operating Temperature | 00C to 400C | | * Relative Humidity | Maximum relative humidity 80% for temperature upto 310C decreasing linearly to 50% relative humidity at 400C | | * Altitude | Operating below 2000 m | | * Storage Temperature | -200C ~ 600C < 80% R.H. (With Battery removed) | | * Temperature Coefficient | Nominal 0.15 x (specified accuracy) /0C @ (00C ~ 180C or 280C ~ 400C), or otherwise specified. | | * Sensing | True RMS | | * Power supply | Alkaline AAA (ANSI-24A/IEC-LR03) x 2 batteries. | | * Power Consumption | 7.9 mA typical | | * APO Timing | Idle for 30 minutes | | * APO Consumption | 20 µA typical on all functions. | | * Dimension | 190(L) x 63(W) x 32(H)mm | | * Weight | 139gm approx. | | * Jaw opening & Conductor diameter | 26mm max. | | * Accessories | Test leads(pair), Batteries installed, User’s manual & Soft carrying case. | |
Clamp-on MeterItem Code: KM-602 Item Code: KM-602 We are involved in manufacturing a wide range of 400A DC/AC Autoranging True RMS Clamp-on Meter With Full Multimeters Ranges. This range is known for its high accuracy, superior performance, easy usage, sturdy construction and operational reliability. Furthermore, our products are available at industry leading prices for the benefit of the clients. | SPECIAL FEATURES : |
| | • Versatile & Handy | | • Backlight display | | • Fully Autoranging on all functions for ease of use | | • 4000 Counts high resolution, Fast measurements | | • AC True RMS Voltage & Current Functions | | • 30ms Max HOLD to capture in-rush currents | | • DCA / ACA 0.1A to 400A non-invasive current measurements. | | • Display Hold, PEAK-rms MAX HOLD & Data Hold | | • Relative Zero feature | | • Measure line-level ACV frequency via test leads | | • Fast Audible Continuity | | • Diode Test | | | | GENERAL SPECIFICATIONS : | | * Display : 3-3/4 digits 4000 counts LCD display | | * Update Rate : 3 per second nominal | | * Jaw opening & Conductor diameter : 30mm max | | * Sensing : True RMS sensing | | * Polarity : Automatic | | * Low Battery : Below approx 2.4V | | * Operating Temperature : 0oC to 40oC | | * Relative Humidity : Maximum relative humidity 80% for temperature upto 31oC decreasing linearly to 50% Relative Humidity at 40oC | | * Altitude : Operating below 2000m | | * Storage Temperature : -20oC to 60oC, < 80% R.H. (With battery removed) | | * Temperature Coefficient : nominal 0.15 x (specified accuracy) / °C @ (0oC-18oC or 28oC-40oC), or otherwise specified | | * Power supply : Standard 1.5V AAA Battery x 2. | | * Power Consumption : DCA & ACA : 11mA typical ; Other function : 2.9mA typical | | * APO Timing : Idle for 30 minutes | | * APO Consumption : 190µA typical | | * Dimension : 188(L) x 63(W) x 40(H) mm | | * Weight : Approx. 218 gms | | * Accessories : Test leads (pair), Battery installed, User's Manual, Carrying Case | | | | | |
|