Showcase
View all our products / services as a slide show.
 |
 |
High Safety UL Approved Digital Multimeters
|
|
We use only superior quality raw material to design our range of High Safety UL Approved Digital Multimeters. This raw material is sourced from our reliable vendor base, hence, is in compliance with the international quality norms and guidelines. Furthermore, our large product line consists of the following:
|
| AC True RMS Digital MultimeterItem Code: KM829 Our clients can avail from us superior quality AC/DC True RMS Digital Multimeter at affordable prices as per their requirements. Furthermore, our clients can purchase these AC/DC True RMS Digital Multimeters from us with customized solutions to meet their specific needs and demands. Features: - 4 Digit 10,000 counts large easy to read LCD display
- Fast measurements, 5 /sec
- Fully auto-ranging
- Dual digital display
- 41 segment analog bar-graph updates 60/sec
- 0.08% High basic DCV accuracy
- Optional purchase USB cable & software for Win98/2k/XP/Vista
- Intelligent auto power off
- Data hold
- Relative zero mode
- Audible & visible beep jack TM input warning against improper plug in
- AC, AC+DC true RMS conversion
- Record max/min readings, auto-ranging
- Crest (peak hold) max/min readings, auto-ranging
- Non-contact EF-detection (NCV)
- Probe-contact EF-detection for more precise indication of live
- Autocheck TM feature (automatic DCV, ACV & Ohms selection)
- Lo-Z Volts to drain ghost voltages (autocheck TM feature)
- Back-lighted large easy to read LCD display
- dBm readings, 20 selectable impedance values
- DCV 0.01mV to 1000V
- ACV 0.01mV to 1000V
- AC+DCV 0.01mV to 1000V
- DCA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- ACA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- AC+DCA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
Safety: - Double insulation per IEC61010-1 2nd Ed.,EN61010-1 2nd Ed., UL61010-1 2nd Ed. & CAN /CSA C22.2 No. 61010.1-0.92 to Category IV 1000V AC & V DC
- Transient protection: 12kV (1.2/50µs surge)
- Pollution degree:2
- Measurement category: CAT IV 1KV
- E.M.C.: Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4 3, En61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)
- In an RF field of 3V/m: Capacitance function is not specified
Other function ranges: - Total accuracy = Specified accuracy + 100 digits
- Overload protections: 600VDC and VAC RMS
- Optional purchase magnetic hanger
- 600V (Ohm, capacitance & all other functions) input protection
- 600V High breaking capacity fuses protected on current inputs
- LVD meets EN61010-1 CAT IV 1kV
- Rugged fire retarded casing with battery access door
- Replaceable protective holster with probe-holders & tilt-stand
|
AC DC True RMS Mobile Logger Digital Multimeters We offer our clients only premium quality AC/DC True RMS Mobile Logger Digital Multimeters. These multimeters are specially designed using finest grade raw material that is sourced from our authentic vendor base. This material is, thereafter, tested at our end to ensure that it is in adherence with the international quality standards. Features: - Dual digital display
- 41 segment analog bar-graph updates 60/sec
- 0.08% high basic dCV accuracy
- Optional purchase USB cable & software for Win98/2k/XP/Vista
- Intelligent auto power off
- Data hold
- 87000 Stand-alone data-logging function (points at single display mode)
- 43000 Stand-alone data-logging function (points at dual display mode)
- Multiple data recording
- 4 Digit 10,000 counts large easy to read LCD display
- Fast measurements, 5 /sec
- Fully auto-ranging
- Relative zero mode
- Audible & visible beep jack TM input warning against improper plug in
- AC, AC+DC true RMS conversion
- DCV 0.01mV to 1000V
- ACV 0.01mV to 1000V
- AC+DCV 0.01mV to 1000V
- DCA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- ACA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- AC+DCA 0.1mA to 10A; 20A for 30 seconds per 5 minutes cooling
- Ohms 0.1Ω to 60MΩ
- Conductance 0.01nS to 100nS
- Capacitance 60.00nF to 25mF
- Record max/min readings, auto-ranging
- Crest (peak hold) max/min readings, auto-ranging
- Non-contact EF- detection (NCV)
- Probe-contact EF- detection for more precise indication of live
- AutocheckTM feature (automatic DCV, ACV & Ohms selection)
- Lo-Z Volts to drain ghost voltages (AutocheckTM feature)
- Back-lighted large easy to read LCD display
- T1 Type-K temperature readings -50oC to 1000oC
- T2 Dual type-K temperature readings -50oC to 1000oC
- Line level frequency 5Hz to 200kHz
- Logic level frequency 5Hz to 2MHz
- Logic level duty cycle readings 0.1% to 99.99%
- Diode tester
Safety: - Double insulation per IEC61010-1 2nd Ed.,EN61010-1 2nd Ed., UL61010-1 2nd Ed. & CAN /CSA C22.2 No. 61010.1-0.92 to Category IV 1000V AC & V DC
- Transient protection: 12kV (1.2/50µs surge)
- Pollution degree:2
- Measurement category: CAT IV 1KV
- E.M.C.: Meets EN61326-1:2006 , EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11
- In an RF field of 3V/m: Capacitance function is not specified
Other function ranges: - Total accuracy = Specified accuracy + 100 digits
- Optional purchase magnetic hanger
- 1000V (Ohm, capacitance & all other functions) input protection
- 1000V High breaking capacity fuses protected on current inputs
- LVD meets EN61010-1 CAT IV 1kV
- Overload protections : 1000VDC and VAC RMS
- Rugged fire retarded casing with battery access door
- Replaceable protective holster with probe-holders & tilt-stand
| |
| Hand Held Digital Multimeter ( 4-4/5 digits 50,000 counts)Item Code: KM-857 We export a wide range of Hand Held Digital Multimeters (4-4/5 digits 50,000 counts) to different parts of the world at cost-effective prices. Furthermore, we offer customization for our range of products to cater to the varied specifications and application requirements of the clients spread across the globe. Specifications: - Display: 4-4/5 digits 50,000 counts. Selectable stable mode 5-4/5 digits 500,000 counts for DC voltage, 6 digits 999,999 counts for Hz
- Polarity: Automatic
- Update rate: 4-4/5 digits fast mode: 5 per second nominal;5-4/5 digits stable mode: 1.25 per second nominal; 42 segments bar graph: 60 per second max
- Low battery: Below approx. 7V
- Operating temperature: 0oC to 45oC
- Relative humidity: Maximum relative humidity 80% R.H. For temperature up to 31oC decreasing linearly to 50% relative humidity at 45oC
- Pollution degree:2
- Storage temperature: -20oC to 60oC, < 80% R.H. (with battery removed)
- Altitude: Operating below 2000m
- Temperature coefficient: Nominal 0.1 x (specified accuracy) / oC @ (0oC -- 18oC or 28oC – 40oC), or otherwise specified
- Sensing: AC, AC + DC True RMS
- Power supply: Single alkaline 9V battery
- Power consumption: 5mA typical
- APO Timing: Idle for 4.5 minutes
- APO Consumption: 20µA
- Dimension: 186(L) mm x 87(W) mm x 35.5(H) mm; 198(L) mm x 97(W) mm x 55(H) mm with holster
- Weight: 390 gm, 500 gm with holster
Special Features: Record Max, MIN, MAX-MIN readings. Crest (instantaneous pead hold) max, min, max-min readings. Relative zero mode. 500,000 counts high resolution stable reading mode. Back lighted display dBm readings. T1-T2 differential temperature readings %4-20 mA loop current readings. High noise rejection filtered line level frequency mode. Data hold. Audible & visible input warning Standard Accessories: Test leads (pair), holster, battery installed, user’s manual, K-type thermocouple x 1 Optional Accessories: PC interface Kit (RS232 optical adapter cable + RS232 software CD) , pins to type-K socket plug adapter High Safety Digital Multimeters “UL” approved Safety: The meter is protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd edition (2001) to CAT III 1000V & CAT IV 600V. The meter also meets UL3111-1 (1994) and CSA C22.2 No. 1010-1-92 to CAT III 1000V. Category IV safety standard was first released in IEC61010-1 2nd edition in year 2001, and was yet an UL published standard at the time this catalog was written - E.M.C.: Meets EN61326(1997, 1998/A1), EN61000-4-2(1995) and EN61000-4-3(1996)
- Overload Protections: µA & mA : 1A/1kV(or 0.44A/1kV)IR 10kA, F fuse A: 15A/1kV, IR 10kA (or 11A/1kV, IR 20kA), F fuse V: 1050 V RMS, 1450 V peak mV, Ω & Others : 1050 V RMS, 1450 V peak
- Transient Protection: 8kV lightning surge (1.2/50µs)
|
Hand Held Digital Multimeter Model KM 857 We manufacture and supply a superior range of Hand Held Digital Multimeters that are highly demanded in various industrial applications. Our range is designed using premium grade raw material that is in compliance with the international quality standards and norms. Furthermore, we offer customized solutions with our product range to the clients as per their diverse needs and specifications. Features: - Display: 4-4/5 digits 50,000 counts. Selectable stable mode 5-4/5 digits 500,000 counts for DC Voltage, & 6 digits 999,999 counts for Hz
- Polarity: Automatic
- Update Rate: 4-4/5digits fast mode : 5 per second nominal; 5-4/5 digits stable mode: 1.25 per second nominal; 42 segments bar graph : 60 per second max
- Low Battery: Below approx. 7V
- Operating Temperature: 0oC to 45oC
- Relative Humidity: Maximum relative humidity 80% for temperature up to 30°C decreasing linearly to 50% relative humidity at 45°C
- Pollution Degree: 2
- Storage Temperature: -20°C to 60°C, 80% R.H. (With battery removed)
- Altitude: Operating below 2000m
- Temperature Coefficient: Nominal 0.1 x (specified accuracy) / oC @ (0oC -- 18oC or 28oC -- 40oC), or otherwise specified
- Sensing: AC, AC+DC True RMS
- Power Supply: Single alkaline 9V battery
- Power Consumption: 5mA typical
- APO timing: Idle for 4.5 minutes
- APO Consumption: 20µA
- Dimension: 186(L) mm x 87(W) mm x 35.5(H) mm; 198(L) mm x 97(W) mm x 55(H) mm with holster
- Weight: 390 gm, 500 gm with holster
- Special Features: Record max, min, max-min reading. Crest (instantaneous peak hold) max, min, max-min reading. Relative zero mode. 500,000 counts high resolution stable reading mode. Back lighted display dBm readings. %4-20mA loop current readings. High noise rejection filtered line level frequency mode. Data hold. Audible & visible input warning
- Standard Accessories:Test leads (pair), holster, battery installed, user’s manual, carrying case
- Optional Accessories: PC interface Kit (RS232 optical adapter cable + RS232 Software floppies)
Safety: The meter is protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd edition (2001) to CAT III 1000V & CAT IV 600V. The meter also meets UL3111-1 (1994) and CSA C22.2 no. 1010-1-92 to CAT III 1000V. Category IV safety standard was first released in IEC61010-1 2nd edition in year 2001, and was yet an UL published standard at the time this catalog was written. - E.M.C.: Meets EN61326(1997, 1998/A1), EN61000-4-2(1995) and EN61000-4-3(1996)
- Overload Protections: µA & mA: 0.63A/500V, IR 100kA, F fuse A:12.5A/500V, IR 10kA, F fuse V: 1050 V RMS, 1450 V peak mV, Ω & Others : 600 VDC/VAC RMS
- Transient Protection: 8kV lightning surge (1.2/50µs)
| |
| Digital Multimeter Mobile LoggerItem Code: KM-511KM Model KM 511 / KM 515 We are offering only world-class range of Digital Multimeter Mobile Loggers that are exclusively used in different industrial applications. In addition to this, we make sure that our range is precisely designed using high grade raw material that is in adherence with the industry norms and guidelines. Features: - Display: 3-5/6 digits 5000 counts LCD display
- Update Rate: Digital data: 5 per second nominal; 52 segments bar graph: 60 per second nominal
- APO timing: Idle for 17 minutes
- Dimension: L186mmXW87mmXH35.5mm; L98mm X W97mm X H55mm with holster
- Weight: 340 gm; 430 gm with holster approx.
- Safety: Meets EN61010-1, UL3111-1, CSA C22.2 No. 1010-1, and IEC1010-1 CAT III for 1000V DC & AC, and CAT IV for 600V DC & AC
- E.M.C.: Meets EN55022(1994/A1; 1995/class B) & EN50082-1(1992)
- Overload Protections: µA & mA : 1A/240V Fuse, IR 10kA; A: 13A/240V Fuse, IR 10kA
- V: 1050 V RMS, 1450 V peak mV: 600V DC/VAC RMS; Ω & Others: 600 VDC/VAC RMS
- Transient Protection: 8 kV (1.2/50 µs surge)
- Power Consumption: 2.7 mA typical
- Special Features: Data hold; back lighted display; on screen data logging 5400 points for KM511 & 43000 points for KM515 with selectable sampling interval 0.05, 1,20, 40, 60, 120, 240, & 480 seconds
- Standard Accessories: Test leads (pair), holster, battery installed, user’s manual, banana plug K type thermocouple, carrying case
- Optional Accessories: PC interface Kit (RS232 optical adapter cable + software CD)
- Low Battery: Below approx. 7V
- Operating Temperature: 0°C to 35°C, 0-80% R.H.; 35°C to 50°C, 0-70% R.H.
- Storage Temperature: -20°C to 60°C, 80% R.H. (with battery removed)
- Power Supply: single alkaline 9V battery
- Sensing: True RMS for KM511 & Km515
|
Digital MultimeterItem Code: KM-655 We bring forth an exceptional range of Digital Multimeters, which is specially developed using premium quality raw material that is procured from our reputed vendor base. The sourced material is then stringently tested at our premises using modern techniques and machines for designing superior quality Digital Multimeters. Features: - 3 5/6 digits 6,000 counts large easy to read LCD display
- Transient protection up to 8KV (1.2/50 µs) lightning surge
- Fully auto-ranging
- Max./min. recording mode
- Low battery indication
- Probe-contact EF- detection for more precise indication of live
- ACV 0.1mV to 1000V
- DCV 0.1mV to 1000V
- ACA 0.001A to 10A
- DCA 0.001A to 10A
- Ohm 0.1Ω to 60 MΩ
- Capacitance 60nF to 2000F
- Line level frequency 40Hz to 60KHz
- Diode tester
- Rugged fire retarded double injected casing
- 600V (input protection)
- 0.5% basic DCV accuracy
- Fast measurements, 5/sec
- Intelligent auto power Off
- Data hold
- Non-contact EF- detection (NCV)
- Beep-jack input warning against improper A-terminal plug in
- Fast audible continuity < 100mS
- Battery access door with probe holders
- LVD meets EN61010-1 CAT III 1KV. & CAT 1V 600V
- EMC EN61326 (97,98 / Al) / EN 61000-4-2 (95) / EN61000-4-3(96)
General Specifications: - Operating temperature: 10OC ~ 50OC < 80% R.H.
- Storage temperature: -20OC ~ 60OC < 80% R.H. (with battery removed)
- Sensing: Average sensing
- Pollution degree: 2
- In an RF field of 3V/m: Capacitance function is not specified
- Other function ranges: Total accuracy = Specified accuracy + 45d
- Performance above 3V/m is not specified
- Safety: The meter is protected, against the users, by double insulation per EN61010-1, IEC610101 2nd Ed., UL61010-1 2nd Ed. & CAN/CSA C22.2 No.61010.1-0 to “CAT III 1000V & CAT IV 600V”. Terminals (to COM) ratings. V: Category III 1000 Volts AC & DC, and CAT IV 600 Volts AC & DCA: CAT IV 600V AC & 500VDC, O/L protection. V: 1050V RMS, 450V RMS A: 15A/600V, IR 100KA, F fuse & Others: 600VDC/VAC RMS
- Low battery: Below approx. 5.5V
- Power supply: Standard 9V battery
- Power consumption (typical): 3µA for a function
- APO consumption(typical): 20µA typical except 50µA
- APO timing: IDLE approx. > 30 minutes
- Dimension: 173(L) x 83(W) x 48.5(H)mm
- Weight: Approx. 300gm
- Accessories: Battery installed, test lead pair, manual & carrying case
| |
| Digital Multimeters (Model - 5040 / 5040 T)Item Code: 5040-5040T We have developed an impeccable range of Digital Multimeters, which uses latest scientific technology and is widely used in several industrial applications. Apart from this, we use high grade raw material to design our large product line that ensures that the range is durable and reliable in operation under extreme conditions. Features: - Display: 3-4/5 digits 5000 counts LCD display
- Update rate: Fast data: 5/second nominal; Ultra-high-speed 52 segment bar-graph: 60/second
- Sensing: Average sensing, true RMS (For Model-5040-T)
- Operating Temperature: 0oC to 45oC
- Relative humidity: Maximum relative humidity 80% for temperature up to 31oC decreasing linearly to 50% relative humidity at 45oC
- Storage temperature: -20oC to 60oC, 80% R.H. (With battery removed)
- Pollution degree: 2
- Altitude: Operating below 2000m
- Temperature coefficient: nominal 0.15 x (specified accuracy)/ oC @ (0oC to 18oC or 28oC to 45oC), or otherwise specified
- Power supply: Single 9V battery
- Power consumption: 2.6mA typical
- Low battery: Below approx. 7V
- APO timing: Idle for 17 minutes
- Accessories: Test leads (pair), holster, battery (installed), user’s manual, carrying case
- Optional Accessories: PC interface kit (RS232 optical adapter cable + software CD), RS232-USB Convertor
- Weight: 340gm, 430gm with holster
- Dimension: 186(L)mm x 87(W)mm x 35.5(H)mm, 198(L)mm x 97(W)mm x 55(H)mm with holster
- Special features: Data hold, range-hold, back lighted display, optical isolated RS232 PC-interface capabilities
Safety: E. M. C.: Meets EN61326 (1997, 1998/A1), EN61000-4-2(1995) and EN61000-4-3(1996). Also meets former standards EN55011 (1991) and EN50082-1(1997). In an RF field of 3V/m: Capacitance function is not specified - Other function ranges: Total accuracy = Specified accuracy + 30 digits performance above 3V/m is not specified
- Transient protection: 8kV lightning surge (1.2/50µs)
Safety: The meter is protected, against the users, by double insulation per IEC61010-1 2nd Edition (2001) to CAT III 1000V & CAT IV 600V. The meter also meets UL3111-1(1994) and CSA C22.2 No. 1010-1-92 to CAT III 1000V. Terminals (to COM) ratings: V: Category III 1000 Volts AC & DC, and Category IV 600 Volts AC & DC, A / µA mA: Category III and Category IV 500 Volts AC and 300 Volts DC. Overload Protections: µA & mA: 0.63A/500V, IR 200kA, F fuse A : 12.5A/500V, IR 20kA, F fuse V: 1050 V RMS, 1450V peak mV, Ω & Others: 600VDC/VAC RMS For Electrical Specification, Click on Tab "For More Details" |
Voltage TesterItem Code: KM-69KM-66 Model- KM 69/KM 66 Our clients can avail from us customization for this range of Voltage Testers to meet their varied specifications and application requirements. Since, our Voltage Testers are commonly used for various industry purposes, we make sure that these are always thoroughly tested for meeting the international quality standards. Features: - Display: 3 digits 1000 counts
- Update rate: 5 per second nominal back light display
- AC-detection shaker bi-color LED hazardous live warning (at > 70VDC / 33VAC) RCD leakage load for 230VAC / 30mA RCD circuit breakers
- Continuity: Audible beeper & visible LED indications
- Automatic DCV, ACV & continuity selection
- Non-contact EF- detection (NCV)
- Probe - contact EF- detection for more precise indication of live
- Overload alert warning (1000V LED flashes when > 1000VAC/DC)
- Operating temperature: -10oC ~ 55oC
- Relative humidity: 20% ~ 96%
- Altitude: Operating below 2000m
- Storage temperature: -10oC ~ 55oC, 20% ~ 96% R.H. (with battery removed)
- Temperature coefficient: Nominal 0.15 x (specified accuracy)/oC @ (-10oC ~ 18oC or 28oC ~ 55oC), or otherwise specified
- Sensing: Average sensing
- Low battery: Below approx. 2.4V; below approx. 2.6V with shaker ON
- Power supply: Standard 1.5V AAA size battery x 2; or 1.5V AAA size alkaline battery x 2
- APO timing: Idle for 15 seconds
- Power consumption (typical): 3mA at Power-on ready; 25mA at 1000VAC full LED indication. 75MA at 1000VAC with shaker ON
- APO consumption (typical): 10 A
- Dimension: 178(L) x 57(W) x 34(H)mm
- Weight: Approx. 174gm
- Special features: High input impedance, indicator self-test, auto-hold, overload-alert warning, EF- detection, AC-detection shaker, bi-color LED hazardous live warning, and RCD trip test
- Accessories: Detachable (black) test lead, screw-on stationary (red) probe, 2 screw-on 4mm tip accessories, batteries installed and user’s manual, carrying case
- Safety: Meets EN61243 voltage class B, EN61010-1 and IEC61010-1 2nd edition (2001) to CAT III 1000V & CAT IV 600V
- Type of protection: IP65 - water and dust resistant. Rugged fire retarded double injected casing
- Pollution degree: 2
- Transient protection: 8kV lightning surge (1.2/50s)
- Measurement category: CAT III 1000V & CAT IV 600V AC & DC
- E. M. C.: Meets EN61326 (1997, 1998/A1), EN61000-4-2 (1995), & EN61000-4-3 (1996): performance is specified in an RF Field of 3V/m. Performance above 3V/m is not specified.
- In an RF field of 3V/m : total accuracy = specified accuracy + 45d
- Overload protection: A & mA: 0.63A/500V, IR 200kA, F fuse A: 12.5A/500V, IR 20kA, F fuse V: 1050 V RMS, 1450V peak mV, Ω & Others : 600VDC/VAC RMS
| |
| Programmable Digital Panel Meters | FEATURES |
| | * Accuracy | : | ± 0.15 % F.S. | | * Dimension | : | 96mm X 48 mm | | * Analog output | | * Digital output | | * Dual Auxillary power | : | 110/220v AC | | * Single /Dual/Triple Display (Select models) | | * Average & TRMS measurment | | * Hi- Lo settings. | | * Replay / pulse outouts. | | * Alarm outputs. | | * 10 years power-off memory for WH & VarH | | RANGE OF DIGITAL PANEL METERS : | | * DMV | : | AC voltage & setting Digital meter | | * DMA | : | AC Current & Setting Digital Metter | | * DMWH / DMQH | : | Watt hour & Varhour Digital Meter | | * DMV3 | : | Digital Programmable AC Voltage Meter ( Triple Diaplay) | | * DMA3 | : | Digital Programmable AC Current Meter (Triple Display) | | * DMVA | : | Microprocessor Voltage & Current Meter | | * DMM/DMQ | : | Watt & Var Digital Meter | | * DMWWH/DMQQH | : | Watt/Watthour & Var/Varhour Digital Meter | | * DMPF | : | Power Factor Digital meter | | * DMF | : | Frequency & Setting Digital Meter | | * DME | : | DC Rate & Setting Digital Meter | | * DMS | : | Current Loop DC Rate & Setting Digital Meter | | * DMD | : | DC Voltage, Current & Setting Digital Meter | | * DMB | : | Load Cell, Strain Gauge & Setting Digital Meter | | * DMU | : | RPM, Speed, Pulse, Length, Fluid & Setting Digital Meter | | * DMP | : | Potentiometer, Level, Position & Setting Digital Meter | | * DML | : | Flow Digital Meter | | * DMG | : | RS-485 Digital Meter | | | | | |
|