Signal Transmitters

Share: Facebook TwitterStumble

Our range is Signal Transmitters is available with customized solutions to meet the varied needs and specifications of the clients. Besides, this range is durable, sturdy in construction, high in performance, reliable in operation and can be availed with competitive prices. Further, this range includes the following:



DC Isolating Transmitter
Large View

DC Isolating Transmitter

We are instrumental at designing our range of DC Isolating Transmitters. This range is basically designed using superlative grade raw material that is in accordance with the industry quality norms and guidelines. Besides, our esteemed clients can avail from us customization for this range as per their individual specifications.

 FEATURES

* Aux. Power AC 85 ~ 265V or DC 85 ~ 300V
* High Accuracy 0.1% RO at 23oC ± 5oC
* Input / Output User Selectable
* PC Plastic Case, DIN Rail or Wall Mounting
* High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
 
 
 
TERMINAL CONNECTIONS
Connect the unit as in the diagram on the right side or refer to the connection diagram label on the side of the unit.
CHECKING
* Terminal wiring : Check that all cables are correctly connected according to the connection diagram.
* Power input voltage : Check voltage of the terminal 10 ' 11
* Input : Check that the input signal is within 0-100%.
*Output : Check that the load resistance meets the described specifications.
ADJUSTMENT PROCEDURE
* This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do
    not need any calibration.
* For matching the signal to a receiving instrument or in case of regular calibration, adjust the output
   as explained in the following.
HOW TO CALIBRATE THE OUTPUT SIGNAL
1) ZERO : Apply 0% input and adjust output to 0%.
2) SPAN : Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure 1) ~ 3).
MAINTENANCE
Regular calibration procedure is explained below :
Warm up the unit for at least 10 minutes. Apply 0%, 25%, 50%, 75% and 100% input signal. Check the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the "ADJUSTMENT PROCEDURE" explained earlier.
CALIBRATE THE RANGE OF THE INPUT AND OUTPUT
 

Current Loop Supply Isolating Transmitter

We manufacture and supply an extensive range of Current Loop Supply Isolating Transmitters, which is highly durable, reliable and exhibits superior performance. Apart from this, we also make sure that our product range is thoroughly tested on different quality parameters before the final consignments are delivered to the clients.

 FEATURES

* Aux. Power AC 85 ~ 265V or DC 85 ~ 300V
* High Accuracy 0.1% RO at 23oC ± 5oC
* Output User Selectable
* PC Plastic Case, DIN Rail or Wall Mounting
* High Dielectric Strength (AC 1.5KV/ Min, between Input/Output/Power)
 
 
 
TERMINAL CONNECTIONS
Connect the unit as in the diagram on the right side or refer to the connection diagram label on the side of the unit.
CHECKING
* Terminal wiring : Check that all cables are correctly connected according to the connection diagram.
* Power input voltage : Check voltage of the terminal 10 ' 11
* Input : Check that the input signal is within 0-100%.
* Output : Check that the load resistance meets the described specifications.
ADJUSTMENT PROCEDURE
* This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do
   not need any calibration.
* For matching the signal to a receiving instrument or in case of regular calibration, adjust the output
   as explained in the following.
HOW TO CALIBRATE THE OUTPUT SIGNAL
1) ZERO : Apply 0% input and adjust output to 0%.
2) SPAN : Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure 1) ~ 3).
MAINTENANCE
Regular calibration procedure is explained below :
Warm up the unit for at least 10 minutes. Apply 0%, 25%, 50%, 75% and 100% input signal. Check the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the "ADJUSTMENT PROCEDURE" explained earlier.
CALIBRATE THE RANGE OF THE INPUT AND OUTPUT
 
Current Loop Supply Isolating Transmitter
Large View
RTD Isolating Transmitter
Large View

RTD Isolating Transmitter

We hold expertise in developing a finest quality range of RTD Isolating Transmitters that are in adherence with the international standards and norms. Furthermore, we use only superior grade raw material to manufacture our products, hence, these are sturdy in construction, light in weight and durable in life.

 FEATURES

* Aux. Power AC 85 ~ 265V or DC 85 ~ 300V
* High Accuracy 0.1% RO at 23oC ± 5oC
* Input / Output User Selectable
* PC Plastic Case, DIN Rail or Wall Mounting
* High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
 
 
 
TERMINAL CONNECTIONS
Connect the unit as in the diagram on the right side or refer to the connection diagram label on the side of the unit.
CHECKING
* Terminal wiring : Check that all cables are correctly connected according to the connection diagram.
* Power input voltage : Check voltage of the terminal 10 ' 11
* Input : Check that the input signal is within 0-100%.
* Output : Check that the load resistance meets the described specifications.
ADJUSTMENT PROCEDURE
* This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do
    not need any calibration.
* For matching the signal to a receiving instrument or in case of regular calibration, adjust the output
   as explained in the following.
HOW TO CALIBRATE THE OUTPUT SIGNAL
1) ZERO : Apply 0% input and adjust output to 0%.
2) SPAN : Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure 1) ~ 3).
MAINTENANCE
Regular calibration procedure is explained below :
Warm up the unit for at least 10 minutes. Apply 0%, 25%, 50%, 75% and 100% input signal. Check the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the "ADJUSTMENT PROCEDURE" explained earlier.
CALIBRATE THE RANGE OF THE INPUT AND OUTPUT
 

Thermocouple Isolating Transmitter

These Thermocouple Isolating Transmitters are commonly used for various industry purposes, thereby, can be availed at economical prices as per our clients' application requirements. In addition to this, we offer customized packaging for our range of products to ensure that these instruments are delivered safely to the clients.

 FEATURES

* Aux. Power AC 85 ~ 265V or DC 85 ~ 300V
* High Accuracy 0.1% RO at 23oC ± 5oC
* Input / Output User Selectable
* PC Plastic Case, DIN Rail or Wall Mounting
* High Dielectric Strength (AC 1.5KV/Min, between Input/Output/Power)
 
TERMINAL CONNECTIONS
Connect the unit as in the diagram on th right side or refer to the connection diagram label on the side of the unit.
CHECKING
* Terminal wiring : Check that all cables are correctly connected according to the connection diagram.
* Power input voltage : Check voltage of the terminal 10 ' 11
* Input : Check that the input signal is within 0-100%.
*Output : Check that the load resistance meets the described specifications.
ADJUSTMENT PROCEDURE
* This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do not    need any calibration.
* For matching the signal to a receiving instrument or in case of regular calibration, adjust the output    as explained in the following.
HOW TO CALIBRATE THE OUTPUT SIGNAL
1) ZERO : Apply 0% input and adjust output to 0%.
2) SPAN : Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure 1) ~ 3).
MAINTENANCE
Regular calibration procedure is explained below :
Warm up the unit for at least 10 minutes. Apply 0%, 25%, 50%, 75% and 100% input signal. Check the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the "ADJUSTMENT PROCEDURE" explained earlier.
Thermocouple Isolating Transmitter
Frequency To DC Isolating Transmitter

Frequency To DC Isolating Transmitter

We have vast industry experience to export a wide range of Frequency To DC Isolating Transmitters to countries spread all over the world. Moreover, we provide customization for our range to meet the varied specifications and application requirements of the clients. This range is highly credited for its durability and cost-effectiveness.

  FEATURES

* Aux. Power AC 85 ~ 265V or DC 85 ~ 300V
* High Accuracy 0.1% RO at 23oC ± 5oC
* Output User Selectable
* PC Plastic Case, DIN Rail or Wall Mounting
* High Dielectric Strength (AC 1.5KV/ Min, between Input/Output/Power)
 
 
TERMINAL CONNECTIONS
Connect the unit as in the diagram on the right side or refer to the connection diagram label on the side of the unit.
CHECKING
* Terminal wiring : Check that all cables are correctly connected according to the connection diagram.
* Power input voltage : Check voltage of the terminal 10 ' 11
* Input : Check that the input signal is within 0-100%.
*Output : Check that the load resistance meets the described specifications.
ADJUSTMENT PROCEDURE
* This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do not    need any calibration.
* For matching the signal to a receiving instrument or in case of regular calibration, adjust the output    as explained in the following.
HOW TO CALIBRATE THE OUTPUT SIGNAL
1) ZERO : Apply 0% input and adjust output to 0%.
2) SPAN : Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure 1) ~ 3).
MAINTENANCE
Regular calibration procedure is explained below :
Warm up the unit for at least 10 minutes. Apply 0%, 25%, 50%, 75% and 100% input signal. Check the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the "ADJUSTMENT PROCEDURE" explained earlier.

Potentiometer,Level Transmitter,Position Transmitter

We are offering our clients an exclusive range of Potentiometers, Level Transmitters & Position Transmitters, which is highly demanded for its easy usage, operational reliability, long functional life and economical prices. Apart from its cost-effectiveness, our range can be customized as per the preferences of the clients.

  FEATURES

* Aux. Power AC 85 ~ 265V or DC 85 ~ 300V
* High Accuracy 0.1% RO at 23oC ± 5oC
* Input / Output User Selectable
* PC Plastic Case, DIN Rail or Wall Mounting
* High Dielectric Strength (AC 1.5KV/ Min, between Input/Output/Power)
 
 
 
TERMINAL CONNECTIONS
Connect the unit as in the diagram on the right side or refer to the connection diagram label on the side of the unit.
CHECKING
* Terminal wiring : Check that all cables are correctly connected according to the connection diagram.
* Power input voltage : Check voltage of the terminal 10 ' 11
* Input : Check that the input signal is within 0-100%.
*Output : Check that the load resistance meets the described specifications.
ADJUSTMENT PROCEDURE
* This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do not    need any calibration.
* For matching the signal to a receiving instrument or in case of regular calibration, adjust the output    as explained in the following.
HOW TO CALIBRATE THE OUTPUT SIGNAL
1) ZERO : Apply 0% input and adjust output to 0%.
2) SPAN : Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure 1) ~ 3).
MAINTENANCE
Regular calibration procedure is explained below :
Warm up the unit for at least 10 minutes. Apply 0%, 25%, 50%, 75% and 100% input signal. Check the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the "ADJUSTMENT PROCEDURE" explained earlier.
 
Potentiometer,Level Transmitter,Position Transmitter
Large View

Contact us

Mr. Pradeep Goliya
G-17, Bharat Industrial Estate, , Tokershi Jivraj Road
Mumbai, Maharashtra - 400 015, India
Telephone:  +(91)-(22)-24181649/ 24124540/ 24156638

Contact via E-mail

Home | Profile | Products We Offer | Site Navigation | Contact Us | Enquiry
Member IndiaMART.com © KUSAM ELECTRICAL INDUSTRIES LTD.. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry