Portable LPG Density Meters

Item Code: LPGDi


Overview:

Unique Laboratory Density Meter is a new development especially for liquefied petroleum gases (LPG) measuring. It is based on the resonant method of density measurements and uses small sample volume. Obtained results are instantly converted to relative density (15°C or 20°C or 60°F) in accordance with ASTM D1250 tables. Readings on the LCD facilitate measuring process and eliminate eventual human error. Compact design makes suitable to any place in your laboratory. Additional car power option makes it portable. Combination with PC or Pocket PC makes it as a complete data managing system. WINDOWS based Software allows necessary data processing and simplifies operation for personnel.

Features
:

  • Precise density and temperature in seconds
  • Excellent correlation to ASTM D1657
  • Small sample volume
  • Readings on LCD
  • Easy to operate
  • Automatic temperature compensation
  • Data transfer to PC

In-Tank Density Meters

Overview:

LEMIS process use the proven vibrating element technique which is widely accepted as the most accurate method of continuous online density measurement, LEMIS process engineers made new developments by the introducing unique proprietary design of resonant tube sensor allowing accurate measurement of liquid density. An integral high accuracy Pt-1000 probe continuously monitors liquid temperature allowing temperature compensation and future calculation of reference density, concentration or specific gravity. The technology proves high accuracy of measurement and long term calibration stability even in severs operation conditions. It is insensitive to plant vibration, high variation of temperatures, level, mix or turbulence. A choice of wetted parts materials: from stainless steel for general industrial use, Ni-Span-C for most demanding applications, and Hastelloy for applications where ultimate corrosion resistance is required.

Features
:

  • Continuous, on line density monitoring at process conditions
  • Accurately measures density of liquids with viscosity up to 2000cSt
  • Rigorous factory calibration and testing of the transducer
  • Can operate in pressurized tanks
  • Immersion in the tanks up to 30 meters
  • No moving parts, virtually maintenance-free system
  • We also can tune system specification for your specific requirements
  • Hazardous area approvals
  • Insensitive to liquid level, mix or turbulence
  • Large offer of standard product configurations and installation available

Specifications:


Density operating range:

0…2 g/cm3 (0…2000 kg/m3)

Accuracy: ±0.00025 g/cm3 (±0.25 kg/m3)
Repeatability: ±0.0001 g/cm3 (±0.1 kg/m3)
Calibration stability (per year): < ±0.0001 g/cm3 (< ±0.1 kg/m3)
Process Temperature Range: -200°C to +200°C (-328°F to +392°F)
Temperature Effect: 0.005 kg/m3/°C automatically compensated
Ambient Temperature Range: -40°C to +85°C (-40°F to +185°F)

Applications:

  • Density, temperature and concentration monitoring in storage tanks
  • Petroleum products, fuels, lubricants, LPG, LNG
  • Concentrations of acids or corrosive chemical
  • Food, Dairy & Beverages
  • Product identification and consistency
  • Concentration and dilution measurement
  • Monitoring of reaction end in reactors
  • In-tank mixing and blending

LPG Density Meters

Overview:

DLG-400 is completely NEW concept of the combine Density and Level detection system. Two different probes has been mounted together to provide high accurate Density, Level and Temperature measurements in seconds. Simple installation requires only one mounting flange for both Level and Density probes. No separate cabling required. Use the proven vibrating element technique which is widely accepted as the most accurate method of continuous online density measurement, LEMIS process engineers did new step ahead introducing unique proprietary design of resonant tube sensor allowing accurate measurement of liquid density and magnetostrictive probe for level. An integral high accuracy Pt100 probe continuously monitors liquid temperature allowing temperature compensation and future calculation of reference density. The technology proves high accuracy of measurement and long term calibration stability even in sever operation conditions.Industrial touch screen panel with LEMIS Automation Software for continuous data monitoring and processing. Equipped with alarm option to prevent high water level in the tank. DLG-400 is complete fuel management system, which designed to offer the ability to measure simultaneously and continuously both critical variables of the process liquid in one device saving cost of installation and maintenance.

Features:

  • Combined Density, Level and Temperature measurements
  • Density sensor insensitive to liquid level
  • Can operate in open or pressurised tanks
  • Hazardous area approvals
  • Rigorous factory calibration and testing
  • Data monitoring at industrial touch screen panel
  • Complete automation software package

Specifications:


Level Measuring Range: up to 4000 mm
Level Measuring Accuracy: ±1 mm
Level Measuring Resolution: 0.3 mm
Density Operating Range: 0…2 g/cm3 (0…2000 kg/m3)
Accuracy: ±0.00025 g/cm3 (±0.25 kg/m3)
Repeatability: ±0.0001 g/cm3 (±0.1 kg/m3)
Process temperature range: -40oC to + 85oC

Applications:

  • Density monitoring in storage tanks
  • Petroleum products
  • LPG tanks
  • Filling station