Linear Systems, MumbaiLinear Systems, Mumbai
Our Collection

We are offering a wide range of components & burner controllers for boilers and furnaces as well as flame monitoring and evaluation systems for process industries. Our products offer precision solutions to industries like Sugar, Cement, Petrochemical, Fertilizers, Power, etc. The salient features and brief description of our product range is given below:


Burner Controllers

Burner Controllers

We offer burner sequence controllers for big size burners. This range includes 100/200/300 series controllers. The specifications are given below:

For Oil fired Burners/Boilers

• 107 - S - 60, 107 - S - 30 (Standard models with pre purge time of 60 Seconds and 30 seconds)
• 107 - S - FO (controller for furnace oil)
• 107 - M (suitable for Nestler Boilers)
• 107 - TU
• LS - 107 (suitable for IAEC make boilers)
• 150 - P - 6 (equivalent to MA - 150 Controller)

For Gas Fired Burners/Furnaces with UV flame sensing

WITHOUT PILOT FLAME PROVING
• 307 - GI - S Gas controller, with inbuilt UV Amplifier.
• 307 - GE - S, Gas controller, with external UV Amplifier

WITH PILOT FLAME, DAMPER, BLOWER AND IGINITION TERMINALS
• 307 - GID - P (inbuilt Amplifier) & 307 - GE - P (with external amplifier)

FOR GAS FIRED BURNER/FURNACES WITH FLAME ROD SENSING
• 207 - FR - S, with pilot valve option.
• 207 - FRD - AP21 without Pilot. (functionally compatible to LGB - 21 Controller.

Ask for Quote



UV Sensor

We offer a wide range of UV sensor and UV amplifier for oil & gas flames.

UV Sensor
UV Sensors are ideally suited for detecting various types of flames due to Gas, Coal, Oil fired burners in Boiler and Furnaces. These Sensors are designed using very sensitive electronic UV tube. Insensitive to normal light and refractory glow of furnace walls, these UV tube detect UV radiations emitted by the naked flame. Compatible for harsh industrial environment, the sensors are housed in a metal jacket to provide mechanical protection in various mounting features.

UV Amplifier
UV flame amplifiers are used in conjunction with UV flame sensor to detect various types of flames from gas, oil, coal, etc. These amplifiers come with stand alone unit having two potential free relay contact outputs rated at 230 V AC, 5 Amps. The output contacts can be used for alarm, annunciation or trip purposes.

These UV amplifier have site adjustable time delay of 2 - 8 seconds. Useful for installations with high flicker situation, our range of UV amplifier has been found working excellently with UV sensors of various other makes such as Honeywell, Landis & Gyr Satronic etc, which are rated 230 V AC.rms

UV Sensor
Ask for Quote


Flame Rod Amplifiers

Flame Rod Amplifiers

Our flame rod sensor senses the flame using flame detection rectification technology. These amplifiers provide a voltage for the flame electrode. The flame electrodes are immersed in flame to be sensed. The current, generated by the flow of electrons through the flame, is detected by the controller for presence of flame. These sensors are completely insensitive to visible light and refractory glows. It is excellently suited for sensing flame in Gas fired burners.

Ask for Quote



Burner Controllers-700 Series

We offer burner controllers for small and medium sized industries. These controllers are housed in ABS plastic enclosure. The enclosure's overall size is 70 mm (L) x 110 mm (B) x 105 mm ( H). The enclosure consists of a base and plug in controller module, which facilitates easy replacement at different sites. Our range includes:

Models for oil fired burners

• 710 - PR - MA (equivalent to MA-81O controllers) sensing by LDR.
• 712 - PR - 24 - PI4 (equivalent to LOA - 21 & LOA - 24 controllers)

For Gas fired burners

• 722 - FR - P5, where the flame sensing is done by using Flame Rod.
• 732 - UV - P5, where flame sensing is by UV Sensor.

Burner Controllers-700 Series
Ask for Quote


Flame Sensors

Flame Sensors

We offer a wide range of flame sensors, which uses a light dependent resistor (LDR) for sensing flames. These flame sensors essentially sense the Light emitted by flames. It is suited for oil burners in boilers. It is not suitable for furnaces. These sensor senses all types of light including sun light and rays emitted by electric bulbs & tube lights. In this range, we offer:


• Flame Sensor (FS - 1) with Front Viewing
• Flame Sensor (FS - 2) with Side Viewing
• Flame Sensor (FS - 3) Equivalent to Satronic Sensors.

Ask for Quote



Flame Amplifiers

We offer flame amplifiers, which are flame detectors and very sensitive to visible light. These amplifiers used CDS (cadmium sulphate) photo resistor as light sensing device. Suitable for sensing flames in oil fired burners, our range of amplifiers has two potential free relay contacts rated at 230 V AC, 5 Amps.

Flame Amplifiers
Ask for Quote


Sequence Controllers

Sequence Controllers

We offer Sequence Controllers for big size burners. The specifications are given below:

For Oil fired Burners/Boilers

• 107-S-60, 107-S-30 (Standard models with pre purge time of 60 Seconds and 30 seconds)
• 107-S-FO (controller for furnace oil)
• 107-M (suitable for Nestler Boilers)
• 107-TU
• LS-107 (suitable for IAEC make boilers)
• 150-P-6 (equivalent to MA-150 Controller)

For Gas Fired Burners/Furnaces with UV flame sensing

WITHOUT PILOT FLAME PROVING
• 307 - GI - S Gas controller, with inbuilt UV Amplifier.
• 307-GE - S, Gas controller, with external UV Amplifier

WITH PILOT FLAME, DAMPER, BLOWER AND IGINITION TERMINALS
• 307 - GID - P (inbuilt Amplifier) & 307 - GE - P (with external amplifier)

FOR GAS FIRED BURNER/FURNACES WITH FLAME ROD SENSING
• 207 - FR-S, with pilot valve option.
• 207 - FRD - AP21 without Pilot. (functionally compatible to LGB - 21)controller.

Ask for Quote



UV Amplifiers

We offer amplifiers that are suitable for sensing flames in oil fired burners, our range of amplifiers has two potential free relay contacts rated at 230 V AC, 5 Amps.

UV Amplifiers
Ask for Quote


Ignition Transformer

Ignition Transformer

Technical data
Ignition system MKZ 100
(Part No. 0.096 600 017)
Operating voltage 230 V (-15 % + 10 %)
50/60 Hz
Primary Currrent 0.22 A
Output Connection 50 VA
Primary 2 x flat plug 2.8 mm
Secondary 2 x 4 mm drop in pins
Ignition voltage 2 x 7.5 kV
Ignition frequency 25/30 Hz
Ignition spark energy approx 500 ml
Duty cycle 100 %
Sparking distance 1.5 -3mm
Operating temperature 0.60°C
Fitting position as required
Weight 300 g