|
|
| Home | About Us | Our Products | Testimonials | Contact Us | Enquiry |
![]()
![]()
| We have been manufacturing a precision engineered range of Modbus Input Output that are customized as per the specifications of our clients. Fabricated as per the specifications of our clients, these are high on performance and known to deliver optimum efficiency even in rugged conditions. |
|
Item Code: MAS-AIU-8-M Features:-1) Accepts mA, V, RTD, T/C - Programmable 2) 8 channels 16 bit resolution 3) Full Isolation: Supply/input/output and between channels 4) Dual serial Modbus communication port 5) 24VDC aux power supply 6) Programming & calibration through PC software 7) DIN rail mount 8) Cost effective as Distributed IO About Masibus:- Masibus has introduced a new range of low-cost Modbus based remote IO unit, which provide an easy way for integrating analog signals to supervisory SCADA communication port systems. There are several inputs which this model accepts as an input like mA,V, Pt100, different types of thermocouple, etc. Modbus IO module measures all 24VDC aux power field signals with accuracy of 0.1% of FS. MODBUS-IO module is equipped with high speed scanning and all 8 channels are scanned within 1 second irrespective of type of inputs configured. This module is powered by 24VDC auxiliary power supply and power consumption is Programming & limited to 3 watts maximum. This module provides isolation between channel to channel plus all input signals is isolated from power thus protecting the electrical instruments by eliminating PC software ground loop effects. This reduces substantially the undesirable interferences and instabilities in sensor measurements. MODBUS IO can be easily configured and calibrated via the digital interface by using the Windows based MASIBUS mAIM software. MODBUS IO configuration is done via the RS485 inter face by using Modbus RTU commands. The softwaresupplied FREE allows for configuration of MODBUS features as well as complete calibration and diagnosis. It automatically detects active devices in the Modbus Distributed IO 47 network and permits configuration of all parameters. MODBUS IO module is compact in design and sits on DIN rail mounting of the panel. |
Mr. K. Subramaniam
(Managing Director)
No. B/30, Sector - 25, G. I. D. C. Electronic Estate
Gandhinagar,
Gujarat -
382 010,
India
Telephone: +(91)-(79)-23287275/ 23287276/ 23287277
© Masibus Automation And Instrumentation Pvt. Ltd.. All Rights Reserved (Terms of Use)
Developed and Managed by
IndiaMART InterMESH Limited
|
Business Enquiry Form |