We are one of the most eminent names in the industry for the manufacturing and supplying of the best quality range of Process Control Instruments. These instruments are precisely designed in accordance with the industrial standards. We do not make compromise in terms of quality and so we use premium quality of raw material for the manufacturing of these instruments. Our product range includes Dc regulated power supplies, System calibrators, Digital ampere hour meters and many more.
Digital Pressure Indicator
Master PRI1002 Digital Pressure Indicator is intended to Show any Pneumatic Process Signal being a Pressure Signal can also be indicated as a Process Parameter in Engineering unit. The Re Transmission Current Output can be used for any other Controller, Recorder or Totaliser input. This unique Instrument is a very Cost effective solution to handle any Pressure Parameter without requirement of any Transmitter. Specyicution : 1. Input 0.2 to 1.0 Kg/Cmz. (Pneumatic Process Signal). 2. Sensor Piezo Ceramic Pressure Transducer. (Temperature Compensated). 3. Scale function Linear. 4. Re-Transmission Current Output 1 4 - 20. mA. Impedance 1 600. Q. 5. Pressure Connection %" NPT Male. 6. Display Range 1999 - 0 - (+)1999 Counts (max). in user specified Engineering unit & selectable d.p. 7. Display 3% digit, 0.5", 7-Segment, Red LED. 8. Max In-Accuracy (0.1% of Span -1- 1 digit). 9. Operating Temperature..10 45. “C. 10. Temperature Stability 100. ppm. /°C. 11. Operating Humidity 0 - 90. % . RH. at 45. °C. 12. Power Input 110. / 220. V. 110%; 50.Hz. A.C. 13. Mounting Flush Panel. 14. Dimension Bezel : 144 X 72 m.m. (Width X Height). Cutout : 140 X 68 m.m. (Width X Height). Depth : 300. m.m.
Master PRIl002 Digital Pressure Indicator is intended to Show any Pneumatic Process Signal being a Pressure Signal can also be indicated as a Process Parameter in Engineering unit. The Re Transmission Current Output can be used for any other Controller, Recorder or Totaliser input. This unique Instrument is a very Cost effective solution to handle any Pressure Parameter without requirement of any Transmitter. Specqicution : 1. Input 0.2 to 1.0 Kg/Cm2. (Pneumatic Process Signal). Pressure : 0 to 0.5 psi. (0 - 350.m.m. of W.C.). 0 to 250. psi. Type : Gauge / Differential / Absolute 2. Sensor Piezo Ceramic Pressure Transducer. (Temperature Compensated). 3. Scale function Linear. 4. Re-Transmission Current Output : 4 - 20. mA. Impedance : 600. Q. 5. Pressure Connection %" NPT Male. 6. Display Range (-)l999 - 0 - (+)l999 Counts (max). in user specified Engineering unit & selectable d.p. 7. Display 3% digit, 0.5", 7-Segment, Red LED. 8. Max In-Accuracy i(0.l% of Span + 1 digit). 9. Operating Temperature... 10 - 45. °C. 10. Temperature Stability 100. ppm. / °C. 11. Operating Humidity 0 90. % . RH. at 45. °C. 12. Power Input 110. /220. V. :1:10%; 50.Hz. A.C. 13. Mounting Flush Panel. 14. Dimension Bezel : 144 X 72 m.m. (Width X Height). Cutout 2 140 X 68 m.m. (Width X Height). Depth : 300. m.m.
1. Inputrange 4-20. mA./l -5.V. 2. Input Impedance 10.Q. (Current) / 250.K Q. (Voltage). 3. Scale function Linear. 4. Display Range 0 to 1999 counts (max) in user specified Span & engineering unit. 5. Display 3% Digit; 7Segment; 0.5";Red LED. 6. Alarm Set Points 2.Nos. of Independent Alarm Set Points (SP-1 & SP-2) provided. 7. Alarm Mode Internally Selectable HI or LO.(i.e. Each Alarm to be activated in case of input goes above (HI Mode) or below (LO Mode) the corresponding set point. 8. Set Point Adj. Front panel accessible individual screwdriver adjustment is provided for each set point. 9. Set Point Display Push button for selection of SP-1 / SP-2, for display of set point level in display scale & unit. 10. Alarm Contact Change-over contact provided for each set point individually (Hi & Lo). 11. Alarm Cont. Rating 1. Amp. /230 V. A.C. 12. Mounting Flush Panel Mounting. 13. Power Input 110/220 V. t 10.%; 50.Hz. A.C. 14. Transmitter P.S. 24 V. D.C./ 30 mA. (max). 15. Dimension Bezel 2 144 X 72 m.m.(width x height). Cutout : 140 X 68 m.m.(width x height). Depth : 250 m.m.
1. Input Optional : RTD (3-wire) : Pt100, Cu 53, Ni 100 Therrnocouple : J, K, T, R/S. 2. Lineariser ROM table lineariser provided to correct sensor non linearity. 3. Compensation RTD Sensor Lead Wire Compensation Incorporated. TC Cold Junction Compensation Provided. 4. Display Range 0 to 1750 C. (depending on the sensor). 5. Display 4-Digit; 7-Segment; 12.5 mm; Red LED. 6. Accuracy :l:(0.25 % + l. Count). 7. Alarm Set Points 2.Nos. of Independent Alarm Set Points (SP-1 & SP-2) provided. 8. Alarm Mode User’s Programmable for Hi (Temp > SP) or Lo (Temp < SP) or OFF. 9. Set Point Adj. Programmable with Front panel Key Pad. 10. Set Point Display Selectable in PROG Mode for Display of SP-1 / SP-2. and Display Temp in RUN mode. 11. Alarm Contact Selectable NO / NC contact provided for each Alarm. 12. Alarm Indication. Visual Front LED Indication for Alm-1, Alm—2 Condition. 13. Alarm Cont. Rating 2. Amp. /230 V. A.C. 14. Program Protection Access to Program Mode & Calibration mode are separate Lock-code protected with overriding default value loading provision. 15. Retransmission Output 4-20. mA. Corresponding to Programmed Range. (Optional) Impedance : 600. Q.(max). 16. Power Input 110 /220 V. t 10.%; 50.Hz. A.C. 17. Dimension Bezel : 96 X 48 m.m.(width x height). Cutout : 92 X 44 m.m.(width x height). Depth : 250 m.m.
MASTER MVT4020 accepts mV input of Load Cell or DC Current shunt or any other Transducer & delivers Standard signal output of 4-20 mA. This Panel mounting instrument provides perfect 2-wire signal conversion without any local power supply.. Specwcution : 1. Input mV. Range : to be specified (factory Set). 2. Output Range 4-20 mA. 2-wire mode. 3. Power Supply 12 to 40 V. D.C. 4. Loop Impedance (V.p.s. - 12)/0.02 (e.g. for 24V.P.S.); Impedance = (30 - 12) + 0.02 = 600. Q. 5. Function Linear. 6. Accuracy 1 0.5% of Span. 7. Temp. Stability 100. ppm / C. 8. Operating Temp. 10-50 C. 9. Operating. Humidity. 0-90% RH at 45 C. 10. Enclosure Rear Panel Mounting Stand Alone Module. 11. Adjustability Zero & Span Continuously adjustable over 50% of Range. 12. Dimension Height : 120. m.m. Width : 38. m.m. Depth 2 115.m.m.
Master SDM 2030 Signal Isolator is intended to provided electrical isolation in the path of signal transmission & to distribute the signal in three independent channels. The each output is isolated electrically to the input. So input to output isolation as well as output to output isolation is achieved. Specyication : 1. Input 4-20 mA. D.C. 2. Input Impedance Current : 250 Q. 3. Output 3 Nos. (Isolated) 4-20 mA. 4. Output Impedance Maximum - 600.9. 5. Isolation Galvanic Isolation between Input : Output : Power Supply 6. Accuracy Max error 1 0.2% of Span. 7. Operating Temperatures. 10 to 50. °C 8. Storage Temperature 0 to 80. °C 9. Enclosure DIN Rail Mounting Module. 10. Opp. Power Optional : 120 / 240V. 110% ; 50 Hz. A.C. 11. Optional . 12. Dimension Height : 70. mm. Width : 100. mm. Depth : 115 mm.
1. N0. ofinput Channel 8/ 12/ 16. 2. Type of input Optional : Thermocouple : .1, K, R, S, T. & RTD (2-ware) Pt100, Cu50, Ni100. 3. Display Normal Run ; Input (Temp) / Program : SET POINT ;- 4-digit. Channel Display :2digit. 7segment. 12.5mm, Red LED. 4. Power 230/ 115 V.; 410%; 50Hz.; A.C. 5. Range 0 to 1800 C. (To be Specified, depending on the sensor) 6. Resolution 1. C. (Indipendent of Sensor & Range). 7. Accuracy dc (0.1% ofrange + Count). 8. Calibration Password Protected Front Keypad accessible Input Calibration. 9. Compensation. Cold junction compensation for T.C. OR, Leadwire compensation for RTD is incorporated. 10. Broken Sensor Up scale Over Range Indicated. 1 1. Linearisation By ROM table , for sensor nonlinearity is incorporated. 12. Scan Time User Programmable from 1 to 60 sec / Chnl. 13. Scan Mode Auto / Manual - User Selectable. 14. Set Point Two nos of SETPOINT independently Programmable for each Channel. Indication : Front Panel LED Independent for each Channel for both S.P. 15. Program Protection Access to Program Mode is Pass-Word Protected. User’s Program stored in EEPROM (Battery Backup avoided). 16. Contact Output Separate Changeover contact output for Alarm / Trip, Independent for each group (Four Groups A, B, C, D,) Contact Rating : 1.A. /230.V. 17. Group Association Four Groups : A, B, C, D. Independently Programmable for each Channel 18. Audio Annunciation Piezo Buzzer audio annunciation in case of tripping of any set-point. 19. Acknowledge Any Trip can be acknowledged & annunciation is reset. 20. Skip User programmable to skip any No. of unused channel. 21. Dimension Bezel 1 144 x 144 mm. (Width X Height) Cutout : 138 x 138 mm. (Width X Height) Depth : 300. mm.
T-XD Series Time Totaliser are intended to use as elapsed time counter for any Utility System with option for one or two level monitoring. This series of Instrument has got extensive application in different process and engineering industry. Optimization facility is offered for particular application with 4 or 6 digit version. Highly economic for OEM use. Specyicatian : l. Count Range 9999.Hrs 59.Mnts / 9999.Mnts.59.Secs. (Field Programmable) 2. Enable Input Potential Free Contact. 3. Alarm Set Points Factory Set Option : One (-1 R) / Two (-2R) /No Alarm (-0R). 4. Alarm Mode Equal or HI. 5. Rollover Function Restarts from zero. Alann/s are reset in case of Rollover. 6. User Program Set Point l; Set Point 2. 7. Reset Protection Dual Key Reset Function to avoid accidental Reset. In case of Reset, Last data is stored in Backup register. lf required the last data can be revived & counting starts from the last data. In this process Storing ZERO data is protected 8 Alarm Contact Change-over contact provided for each set point individually. 9. Alanrr Contact Rating 2. Amp. /230 V. AC l0. Mounting Flush Panel Mounting. ll. Power Input ll5 /230 V. :l: 10.%; 50.Hz. AC l2. Dimension Bezel : 96 X 96 m.m.(width x height). Cutout : 92 X 92 m.m.(width x height). Depth : 165 m.m.
1. Input range Programmable : 4-20 mA. / RTDPt100. / T.C. J / K. 2. Compensation Cold Junction compensation / Lead-wire Compensation Incorporated. 3. Lineariser Sensor Lineariser Incorporated. 4. Retransmission Current output : 4 20. mA. ; Impedence : 600 Q. (maX). 5. Display Range Programmable 0 to 4000 counts (extendable upto -1999 to 9999 counts) in user specified Span in Engineering unit, with Selectable Decimal Point. 6. Display 4 digit; 7-segment: 0.5"; Super Bright Red LED. 7. Set Point 2. Nos. of Independent set points provided. 8. Alarm Mode Configurable f`or Operation HI or LO f`or Both Alann Set Points. 9. Set Point Adj. Front panel accessible individual adjustment is provided for each set point. 10. Set Point Display Selector for Display of SP-1 / SP-2 Provided. 11. Alarm Contact Change over contact provided f`or each set point individually. 12. Alarm Contact 1. Amp. /230 V. A.C. 13. Mounting Flush Panel Mounting. 14. Power Input 110/ 220 V. 1 10% ; 50Hz. A.C. 15. Dimension Bezel : 96 X 48 mm. (width X height)