Precision Industrial Instrumentation |
|
|
We offer a wide variety of precision industrial instrumentation that includes VA series, digital barometer, indoor air quality etc..
|
 |
|
|
 |
| | Vibration Analyzers Single channel FFT analyzer with 22 hours battery life. Simple operation using only 10 switches. Simultaneous display of acceleration, velocity and displacement. Compact flash memory card applicable. Internal memory holds up to 500 data sets. - For examining machinery vibrations and performing diagnostic routines on various kinds of equipment
- Vibration meter mode and analyzer mode encompassing FFT analysis.
- Simultaneous display of acceleration, velocity and displacement.
- 80 dB dynamic range with 16-bit A/D converter.
- Large LCD panel with EL backlight.
- Operates for more than 22 hours on four IEC R14 (alkaline) batteries.
| Specification | | | Input section | | | Input connector | Connector for standard accelerometer (PV-55) | | Measurement range | Acceleration: 0.02 to 316m/s² RMS Velocity: 0.1 to 1000mm/s RMS Displacement: 0.003 to 28.3mm (EQ p-p) | | Filter | High-pass filter: 3Hz, 10Hz, 1kHz (-10% frequency) Low-pass filter: 1kHz, 5kHz, 20kHz (-10% frequency) | | Input section?EVibration meter mode | | | Processing items | Simultaneous processing of follwing items (digital) Acceleration: rms, peak, crest factor Velocity: rms Displacement: Equivalent P-P value (EQ p-p) | | Input section?EAnalyzer mode | | | A/D converter | 16-bit, delta sigma principle, 51.2 kHz sampling | | Processing items | Waveform, spectrum | | Display range | 80 dB | | Trigger operation | Free-run, repeat, single | | Pre and post trigger function | Yes | | Display section | | | |
| |
 |
|
|
 |
| | Digital Barometer Item Code: PTB220
- For measurements in a wide environmental pressure and temperature range
- High accuracy - class A barometers have a total accuracy of ±0.15 hPa and class B barometers ±0.25 hPa
- Optional display can simultaneously show the barometric pressure, the three-hour pressure trend and the WMO pressure tendency code
- Available with an analog output option
- Ideal for use e.g. ship barometer, transfer standard or replacement for mercury barometers
| |
| |
 |
|
|
 |
| | Indoor Air Quality Survey - Choice of ppb or ppm VOC optimized PID sensors
- Almost all Total VOCs (TVOCs) typically encountered in IAQ situations are detected
- Excellent sensitivity, very low limits of detection (LODs)
- Rapid response; ideal for "bloodhounding" VOC sources and for determining optimum air sample locations.
- %RH and C/F are also included; add up to 3 additional gas sensors in one probe
- Connect to a GrayWolf supplied Pocket PC or to your own PPC or Notebook PC
- Record portable spot measurements, or log unattended over time in secure housing
- Store enhanced survey information; data and text,
drawings, audio notes and more... - On-board list of potential sources of measured VOC levels
- On-board correction values for specific volatiles versus calibration compound
- Load your own application related documents or procedures (.pdf, Word, Excel, HTML)
- Extremely easy to use
- Desktop data analysis and reporting software is included.
| |
| |
|
|