Leveraging on our team of competent engineers who have years of experience in manufacturing complex medical equipment and machinery, we offer a number of apparatus under various categories. These categories include Anaesthesia apparatus, Silicon resuscitators, temperature controlled vaporizers, imported anesthetics and many more. Each apparatus under these categories are carefully designed and manufactured under strict supervision of highly experienced technocrats.


Anaesthesia Apparatus Major (Fabia 282)
Anaesthesia Apparatus Major (Fabia 282)

We offer precision engineered Fabia 282 Powder coated frame & Fabia 282 stainless steel frame under the category.

Specifications
  • Two gases rota meter oxygen & nitrous oxide
  • Oxygen flowmeter range 100cc/min. to 10 litres/min. Nitrous oxide flowmeter range 200cc/min. to 10 litres/min.
  • Goldman type halothane vaporizer
  • Circle absorber with transparent cannister
  • Non-return cum pressure relief valve to minimize risk of back flow of gases
  • Blows off valve when pressure exceeds 200cm of water column fitted
  • Emergency push button at front panel connected to incoming O2 supply (oxygen push button ensures free flow of oxygen at 35-45 ltr. at 3.8 bar)
  • Separate oxygen flowmeter for independent oxygen supply
  • Sline stand locate at above right side of trolley
  • Extended platform at rear to accommodate two B type cylinders
  • Fitted with four large diameter colour coded Gauges two each for O2 & N2O
  • Pin Index Yokes two each for O2 & N2O
  • Change over system for open to close circuit
  • Four castor trolley with front two lockable Wheels
Safety Features
  • N2O automatic cutoff in case failure of oxygen supply
  • Low pressure oxygen audible alarm
  • ORC (oxygen ratio control) oxygen concentration remains above 25%
  • During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off
  • Alternative machine configuration: 2-gas O2/N2O low flow O2/N2O/air 5 tube
  • Rotameter backlight screen with inbuilt re-chargeable battery backup
  • Venturi suction with 600ml Jar for emergency purpose
  • Vaporizers for any agents (customer's preference)
  • Pulse oximeter
  • Bulk conversion unit O2/N2O




Anaesthesia Apparatus Major (Me-202)

Backed by our competent engineers we offer efficacious M-202 anesthesia apparatus major that is equipped with technically improved components. This has various specifications and significant safety features including:

Specifications
  • Long rotating bobbin flowmeter (230 mm) tube calibrated
  • Oxygen flowmeter range 100cc/min. to 8 liters/min., nitrous oxide flowmeter range 200 cc/min. to 12 liters/min.
  • Fresh gas outlet cum emergency oxygen unit located at a convenient position
  • Plenum type ether vaporizer
  • Goldman type halothene vaporizer
  • Built-in space for one more vaporizer
  • Non return cum pressure relief valve
  • Provision to fit ventilator
  • Provision to fit carbon dioxide absorber
  • Provision to accommodate two nos. 10 ltr. cylinders at the back side
  • Table top made of stainless steel
  • Top tray at eye level to keep monitoring instrument
  • Maggill's circuit or bains circuit
  • Fitted with two large diameter gauges each for Oxygen and Nitrous Oxide
  • Two gauges to show pipeline pressure one for O2 for N2O
  • One spacious drawer on smooth runner
  • Pin index Yokes two for oxygen and two for nitrous oxide
  • Change over system for open and close circuit
  • Preset regulators for O2 and N2O two each
  • Shelf for ampule
Safety Features
  • N2O cut off in case failure of oxygen supply
  • Low pressure oxygen audible mechanical alarm
  • HYPOXICGAURD (rotameter ensure protection against singular flow of N2O until a minimum)
  • Flow of 1.5 litre oxygen is released


Anaesthesia Apparatus Major (Me-202)


Anaesthesia Apparatus Major (Me-14)
Anaesthesia Apparatus Major (Me-14)

We offer ME-14 anesthesia apparatus major having significant safety feature like N2O cut off when oxygen flow falls below 10-15 pnds. Apart from this ANESI-14 is available in stainless steel frame, ANSEI-14 SS & panted or powder coated frame. Major specifications include:

Specifications
  • Long rotating bobbin flowmeter (230 mm).
  • Plenum type ether vaporizer.
  • Goldman type halothene vaporizer.
  • Non-return cum pressure relief valve.
  • 50 mm die oxygen guages.
  • 50 mm die nitorious-oxide guages.
  • Table top stainless steel.
  • Top tray for monitoring instruments.
  • Pin indexed yokes for oxygen.
  • Pin indexed yokes for nitorous-oxide.
  • Emergency oxygen supply button.
  • Outlet.
  • Detachable capacious drawer.
  • Maggill's circuit.
  • Stainless/painted (powered coated)frame.
  • N2O cut off system.
  • Preset regulator for O2 & N2O.
  • Wheels with brake.




Anaesthesia Apparatus Major (Me-15)

We have brought ME-15 anesthesia apparatus major with improved design and based of latest technology that ensure easy operation. These apparatus are available with many critical specifications entailing:

Specifications

  • Two gases rotameter oxygen & nitrous-oxide
  • Oxygen flowmeter range 100 cc/min. to 10 litres/min.,nitrous oxide flowmeter range 200cc /min. to 12 litres/min.
  • Standard fresh gas outlet.
  • Change over system open circuit to close circuit.
  • Emergency flush valve at front panel connected to incoming O2 supply
  • Goldman type halothane vaporizer.
  • Parking space for two additional vaporizers.
  • Non-return cum pressure relief valve minimizes risk of back flow of gases.
  • Blows off valve when pressure exceeds 200cm of water column fitted.
  • Provision to fit ventilator.
  • Provision to fit carbon dioxide absorber.
  • Extended platform at rear for two 'B' type cylinder.
  • Table top made of stainless steel.
  • Top tray provided at eye lavel for keeping monitoring equipments.
  • Maggill's or bains circuit.
  • One spacious drawer on smooth runner.
  • Four castor trolley with front two lockable wheels.
  • Pin index yokes two for oxygen and two for nitrous oxide.
  • High-efficiency regulators for reliability two each for O2 & N2O.
Safety Features
  • N2O cut off in case failure of oxygen supply.
  • Low pressure oxygen audible alarm.


Anaesthesia Apparatus Major (Me-15)


Anaesthesia Apparatus Major (Me-16)
Anaesthesia Apparatus Major (Me-16)

We offer technically advanced ME-16 anesthesia apparatus major that is available with many safety features and supported by various technical specifications. Some of the specifications & safety features are:


Specifications
  • Two gases rotameter oxygen & nitrous-oxide
  • Oxygen flowmeter range 100 cc/min. to 10 litres/min., nitrous oxide, flowmeter range 200cc /min. to 12 litres/min.
  • Standard fresh gas outlet.
  • Change over system open circuit to close circuit.
  • Emergency flush valve at front panel connected to incoming O2 supply
  • Goldman type halothane vaporizer.
  • Parking space for two additional vaporizers.
  • Non-return cum pressure relief valve minimize risk of back flow of gases.
  • Blows off valve when pressure exceeds 200cm of water column fitted.
  • Provision to fit ventilator.
  • Provision to fit carbon dioxide absorber.
  • Extended platform at rear for two ''B'' type cylinder.
  • Table top made of stainless steel.
  • Top Tray provided at eye lavel for keeping monitoring equipments.
  • Maggill''s or bains circuit.
  • Three spacious drawer on smooth runner.
  • Four castor trolley with front two lockable wheels.
  • Pin index yokes two for oxygen and two for nitrous oxide.
  • High-efficiency regulators for reliability two each for O2 & N2O.
Safety Features
  • N2O cut off in case failure of oxygen supply.
  • Low pressure oxygen audible alarm.




Anaesthesia Work Station
Item Code: Tmx-9000

We offer technically advanced anaesthesia work station that is available with many safety features and supported by various technical specifications.


Anaesthesia Work Station


Anaesthesia Ventilator
Anaesthesia Ventilator

We offer precision engineered imported anesthetic which is compatible with any anesthesia machine. Our anesthetic ventilators have improved components like microprocessor controlled electronics and sophisticated pneumatics that provide controlled and monitored ventilation.

For safety of human lives these have special arrangement for relief at high pressure alarm limit setting value plus 5 Ultimate relief valve at 80cm H2O.

General
  • Adult and infant are compatible.
  • Operating power source: 85-264,
  • Vac, 50/60Hz, 30 Watts
  • Battery: 12 Vdc,1.2AH/1ea
  • Backup battery capacity:
  • Capacity for 1 hour (typically 2 hours)
  • Charging time: 4 hours
  • Back-up of working parameters for fast operation
  • Service mode for calibration of the pressure sensor
Control
  • Microprocessor controlled ventilator
  • Volume and time controlled ventilator ( Optional)
  • Power swich : On/Off (stand-by), touch switch
  • Ventilation rate: 5-80 bpm
  • Tidal volume : Maximum 1500ml, 0 to 300ml for infant
  • Note/For using with infant you have to make an order the infant bellow chamber kit additionally
  • I:E ratio: 1:1.0-1:3.0
  • Pressure alarm limit:
  • High /low. 5-80cm H2O) /0-78cm H2O)
  • Automatic and manual alarm setting for high and low
Digital Led Display
  • Patient breathing volume
  • Breathing rate
  • I:E ratio
  • Low pressure alarm limit
  • Peak pressure
  • High pressure alarm limit
Led Indicators
  • Apnea
  • High and low pressure alarm
  • Low battery
  • Internal battery for normal working under electric
  • Power failure charging.
Audible & Visual Alarm
  • Apnea
  • Hig




Infant Silicon Resuscitator

We offer infant silicon resuscitators available with following specific facilities 250 ml silicon bellow, non rebreathing valve with 40cm/H2O pressure release, infant mask, patient connector 15mm inside/22mm outside diameter, oxygen reservoir bag with valve, 1mtr oxygen tubing and many others.


Infant Silicon Resuscitator


Child Silicon Resuscitator
Child Silicon Resuscitator

Our child silicon resuscitators are available with many latest components including 500 ml silicon bellow, non rebreathing valve with 40cm/H2O pressure release, child mask, patient connector 15mm insise/22mm outside diameter, oxygen reservoir bag with valve, 1mtr Oxygen tubing and many other.




Adult Silicon Resuscitator

We offer adult silicon resuscitators that are based on latest improved technology which comprises of many precision components such as 1600 ml folding silicon bellow, non rebreathing valve, adult mask, patient connector 15mm inside/22mm outside diameter, oxygen reservoir bag with valve, 1mtr. oxygen tubing and many more.


Adult Silicon Resuscitator


Temperture Compensated Vaporizers
Temperture Compensated Vaporizers

We design and engineer high performance temperture compensated vaporizers that comprise of high qualitative components. These are equipped with automatic devices ensuring steady vaporizer output over a wide range of ambience temperature. We have ensured significant arrangement for high thermal conductivity which is an indispensable requirement of a vaporizer. Supported by various safety features our temperature compensated vaporizers are quite safe & vital for human lives; some of these include:
  • Keyed fillers or screw fillers
  • Cagemount or selectatec fitting
  • Halothane
  • Isoflurane
  • Enflurane
  • Sevoflurane
  • Low filling port, and many more.




Emergency Kit

It is pneumatically controlled, time cycled, flow adjustable, positive pressure ventilator to meet all emergency situations for respiratory support. Easy to operate with inspirator, expiratory & flow adjustments for breathing frequency of adults & children for standard accessories

  • Refilling
  • Regulator
  • Cylinder Key
  • Small oxygen cylinder.
  • Single stage single gauge
  • Kit for refilling the cylinder.
  • Three sizes face masks with tubing.
  • Provision to use bigger cylinder with tubing fitted with metal end.

Technical Data:
Tidal volume 100ML-1650ML.-Frequency 8-30 Resp. per Min.-Insp. 7 Exp. Ratio 1:1 1:7. - Source 50
PSI Oxygen.

Manual Resuscitator

Manual operated resuscitator with double inlet valves For air & oxygen attachments.

Infusions, Dressings And Others

  • I.V. Rod in two sections
  • I.V. set disposables.
  • Adhesive plaster.
  • Sterilized gauge.
  • Dressing scissor.
  • Dissecting forceps.
  • Tissue forceps
  • Hemostats forceps
  • Needle holder.
  • Disposable syringes.
  • Disposable needles.
  • Splints.
~


Emergency Kit
Anaesthesia Apparatus Major (Fabia 282)
Anaesthesia Apparatus Major (Me-202)
Anaesthesia Apparatus Major (Me-14)
Anaesthesia Apparatus Major (Me-15)
Anaesthesia Apparatus Major (Me-16)
Anaesthesia Work Station
Anaesthesia Ventilator
Infant Silicon Resuscitator
Child Silicon Resuscitator
Adult Silicon Resuscitator
Temperture Compensated Vaporizers
Emergency Kit

Member IndiaMART.comCopyright © Medical Engineers (ESTD.1966), New Delhi, All Rights Reserved (Terms of Use)
Developed by IndiaMART InterMESH Limited